| 1313V1002639N | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1975-1977 | 1977 | | NULL | 2013-09-16 00:00:00 | NULL | NULL | NULL | 35 | NULL | NULL | NULL | | | E | F | 253.03 | 59.21 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | métal sans rupture de pont thermique | air sec | | NULL | 0 | 0 | 0 | 5 | 2.5 | NULL | est ouest | 4.8 | 4.8 | NULL | 0 | [ "est", "ouest" ] | 0.319 | ITI | NULL | murs en blocs de béton creux | 20 | 34 | 16 | 34 | 1.11 | | | | non isole | dalle béton | 35 | 35 | 2 | NULL | | | | ITE | plafond mitoyen non deperditif | 35 | 0 | NULL | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002640F | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1989 | | NULL | 2013-09-16 00:00:00 | NULL | NULL | NULL | 112 | NULL | NULL | NULL | | | C | D | 120 | 32 | individuel | fioul | chaudiere fioul standard | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | chaudiere fioul standard | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 2.42 | 8.69 | 3.45 | 0 | NULL | tout venant | 2.2 | 2.7 | 0.44 | 0 | [ "nord", "ouest", "sud" ] | 0.098 | ITI | NULL | murs en blocs de béton creux | 20 | 133.36 | 133.36 | 133.36 | 0.35 | | | | ITE | plancher à entrevous isolant | 112 | 112 | 0.61 | NULL | | | | ITI | plafond bois sous solives bois | 57 | 57 | 0.3 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002644J | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1989-2000 | 1989 | | NULL | 2013-09-16 00:00:00 | NULL | NULL | NULL | 19 | NULL | NULL | NULL | | | E | B | 253 | 10 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 2.78 | 0 | 0 | NULL | non traversant | 2.4 | 2.9 | 0.44 | 1 | [ "sud" ] | 0.355 | ITI | NULL | murs en béton banché | 20 | 10.88 | 5.05 | 10.88 | 0.5 | | | | non isole | dalle béton | 18.52 | 0 | 2 | NULL | | | | non isole | dalle béton | 18.52 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002645 | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1974 | | NULL | 2013-09-16 00:00:00 | NULL | NULL | NULL | 54 | NULL | NULL | NULL | | | E | C | 253 | 13 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | | pvc | | | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | NULL | NULL | NULL | 1 | | NULL | non isole | NULL | murs en béton banché | 20 | 63.84 | 0 | 63.84 | 0.54 | | | | | dalle béton | 53.56 | 53.56 | 0.87 | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002646L | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1983-1988 | 1987 | | NULL | 2013-09-16 00:00:00 | NULL | NULL | NULL | 126 | NULL | NULL | NULL | | | D | C | 220.19 | 12.4 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | simple vitrage | bois | argon ou krypton | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 5.14 | 10.64 | 3.88 | 2.91 | NULL | tout venant | 1.5 | 1.5 | 0.52 | 0 | [ "est", "nord", "ouest", "sud" ] | 0.216 | ITI | NULL | murs en blocs de béton creux | 20 | 198.68 | 82.05 | 198.68 | 0.5 | | | | ITE | | 74 | 74 | 0.78 | NULL | | | | ITI | plafond en plaque de plâtre | 67 | 67 | 0.3 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002647M | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2013-09-16 00:00:00 | NULL | NULL | NULL | 37 | NULL | NULL | NULL | | | E | C | 242 | 11 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | argon ou krypton | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 0 | 0 | 1.2 | 3.7 | NULL | non traversant | 2.3 | 2.9 | 0.48 | 0 | [ "est", "ouest" ] | 0.07 | ITI | NULL | murs en blocs de béton creux | 20 | 64.61 | 64.61 | 64.61 | 0.54 | | | | ITI | dalle béton | 36.88 | 36.88 | 0.37 | NULL | | | | ITI | combles aménagés sous rampant | 36.88 | 36.88 | 0.24 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002650G | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1983-1988 | 1988 | | NULL | 2013-09-17 00:00:00 | NULL | NULL | NULL | 89 | NULL | NULL | NULL | | | C | C | 94.92 | 17.28 | individuel | electricite | pac air/air | | gaz | chaudiere gaz condensation | | 0 | NULL | NULL | | | | | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit avec entrées d’air hygroréglables | | double vitrage | métal | air sec | | NULL | 0 | 5.5 | 5.68 | 0 | 0 | NULL | nord sud | 3.1 | 3.1 | NULL | 0 | [ "nord", "sud" ] | 0.219 | ITI | NULL | murs en blocs de béton creux | 20 | 55.38 | 39.85 | 55.38 | 0.35 | | | | non isole | dalle béton | 52 | 52 | 0.37 | NULL | | | | ITI | plafond bois sous solives bois | 52 | 52 | 0.18 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002651H | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1998 | | NULL | 2013-09-17 00:00:00 | NULL | NULL | NULL | 146 | NULL | NULL | NULL | | | C | D | 105.64 | 28.95 | individuel | gaz | chaudiere gaz condensation | | gpl/butane/propane | chaudiere gpl/butane/propane standard | | 0 | NULL | NULL | | | | collectif | | ecs solaire | | gaz | chaudiere gaz condensation | | 1 | NULL | NULL | 0 | Ventilation hybride avec entrées d’air hygroréglables | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 4.5 | 14.13 | 0.26 | 0.89 | NULL | tout venant | 2.4 | 3 | 0.47 | 1 | [ "est", "nord", "ouest", "sud" ] | 0.126 | ITI | NULL | murs en blocs de béton creux | 20 | 136.76 | 136.76 | 136.76 | 0.62 | | | | non isole | plancher lourd type entrevous terre-cuite, poutrelles béton | 100 | 100 | 2 | NULL | | | | | plafond en plaque de plâtre | 99.9 | 99.9 | 0.19 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002653J | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1975-1977 | 1976 | | NULL | 2013-09-17 00:00:00 | NULL | NULL | NULL | 84 | NULL | NULL | NULL | | | D | B | 219.54 | 8.92 | individuel | electricite | pac air/air | | electricite | chaudiere electrique | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | métal avec rupture de pont thermique | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0 | 0 | 5.01 | 9.25 | NULL | est ouest | 2.7 | NULL | 0.52 | 0 | [ "est", "ouest" ] | 0.136 | ITI | NULL | murs en blocs de béton creux | 20 | 93.56 | 90.56 | 93.56 | 1.11 | | | | ITE | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | plafond bois sous solives bois | 84 | 84 | 0.15 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002654K | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2013-09-17 00:00:00 | NULL | NULL | NULL | 104 | NULL | NULL | NULL | | | F | G | 380 | 96 | individuel | fioul | chaudiere fioul standard | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 2.9 | 3.4 | 0 | 9.9 | NULL | tout venant | 3.5 | 4.7 | 0.52 | 0 | [ "est", "nord", "sud" ] | 0.145 | ITI | NULL | murs en briques pleines doubles avec lame d'air | 35 | 95.8 | 95.8 | 95.8 | 2 | | | | non isole | dalle béton | 103.63 | 103.63 | 2 | NULL | | | | non isole | dalle béton | 103.63 | 103.63 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002656M | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-09-17 00:00:00 | NULL | NULL | NULL | 68 | NULL | NULL | NULL | | | E | D | 287 | 22 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 11.9 | 0 | 0 | NULL | non traversant | 4 | 4.7 | 0.52 | 0 | [ "sud" ] | 0.283 | ITI | NULL | murs en béton banché | 25 | 60.22 | 30.1 | 45.35 | 2 | | | | non isole | | 68 | 0 | 2 | NULL | | | | non isole | plafond lourd type entrevous terre-cuite, poutrelles béton | 68 | 0 | 2.5 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002659 | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1974 | | NULL | 2013-09-17 00:00:00 | NULL | NULL | NULL | 56 | NULL | NULL | NULL | | | E | C | 285 | 15 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | | bois | | | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | NULL | NULL | NULL | 0 | | NULL | | NULL | murs en pierre de taille et moellons avec remplissage tout venant | NULL | 21 | 0 | 21 | NULL | | | | non isole | plancher bois sur solives bois | 56.33 | 56.33 | 1.6 | NULL | | | | | plafond bois sous solives bois | 56.33 | 56.33 | 0.43 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002661I | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1974 | | NULL | 2013-09-17 00:00:00 | NULL | NULL | NULL | 69 | NULL | NULL | NULL | | | D | C | 217 | 11 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « avant 1982 » | | | bois | | | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | NULL | NULL | NULL | 0 | | NULL | non isole | NULL | murs en béton banché | 20 | 42.04 | 0 | 42.04 | 0.54 | | | | | | NULL | NULL | NULL | NULL | | | | | dalle béton | 68.62 | 68.62 | 1 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002662J | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2013-09-17 00:00:00 | NULL | NULL | NULL | 64 | NULL | NULL | NULL | | | C | A | 117 | 3 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0 | 8.82 | 1.03 | 0 | NULL | non traversant | 2.3 | 2.7 | 0.44 | 0 | [ "ouest", "sud" ] | 0.297 | ITI | NULL | murs en béton banché | 20 | 55.76 | 23.26 | 35.76 | 0.4 | | | | | dalle béton | 64.3 | 0 | 0.36 | NULL | | | | | dalle béton | 64.3 | 64.3 | 0.25 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002663K | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1989 | | NULL | 2013-09-17 00:00:00 | NULL | NULL | NULL | 120 | NULL | NULL | NULL | | | C | D | 146 | 27 | individuel | electricite | pac air/air | | gaz | chaudiere gaz basse temperature | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 7.44 | 5.2 | 4.52 | NULL | tout venant | 2.4 | 3.1 | 0.47 | 0 | [ "est", "ouest", "sud" ] | 0.161 | ITI | NULL | murs en blocs de béton creux | 20 | 132.44 | 89.28 | 132.44 | 1.14 | | | | ITE | | 60 | 60 | 0.67 | NULL | | | | ITI | combles aménagés sous rampant | 60 | 60 | 0.3 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002664L | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-09-17 00:00:00 | NULL | NULL | NULL | 64 | NULL | NULL | NULL | | | D | B | 214 | 10 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 4.08 | 5.46 | 0 | 0 | NULL | nord sud | 2.2 | 2.6 | 0.44 | 1 | [ "nord", "sud" ] | 0.259 | non isole | NULL | murs en béton banché | 45 | 73.29 | 27.31 | 40.86 | 1.9 | | | | non isole | dalle béton | 63.58 | 0 | 2 | NULL | | | | non isole | dalle béton | 63.58 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002668P | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-09-17 00:00:00 | NULL | NULL | NULL | 71 | NULL | NULL | NULL | | | E | C | 264 | 14 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | | NULL | 0 | 3.4 | 0 | 1.8 | 6 | NULL | tout venant | 2.6 | 2.6 | 0.44 | 0 | [ "est", "nord", "ouest" ] | 0.167 | ITI | NULL | murs en béton banché | 28 | 55.8 | 55.8 | 55.8 | 2 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002670I | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1960 | | NULL | 2013-09-17 00:00:00 | NULL | NULL | NULL | 76 | NULL | NULL | NULL | | | D | B | 220.5 | 10.83 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | métal sans rupture de pont thermique | argon ou krypton | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0 | 1.56 | 5.61 | 2.24 | NULL | tout venant | 3 | 4 | 0.54 | 0 | [ "est", "ouest", "sud" ] | 0.122 | | NULL | murs en blocs de béton pleins | 40 | 76.96 | 67.81 | 76.96 | 0.98 | | | | | | NULL | NULL | NULL | NULL | | | | | plafond lourd type entrevous terre-cuite, poutrelles béton | 71.44 | 71.44 | 0.43 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002673L | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2013-09-17 00:00:00 | NULL | NULL | NULL | 113 | NULL | NULL | NULL | | | E | C | 268 | 15 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | | NULL | 0 | 2 | 10 | 2.7 | 1.5 | NULL | tout venant | 2.7 | 2.7 | 0.44 | 0 | [ "est", "nord", "ouest", "sud" ] | 0.145 | ITI | NULL | murs en blocs de béton creux | 20 | 95.8 | 95.8 | 95.8 | 2 | | | | non isole | | 114 | 114 | 0.37 | NULL | | | | ITI | plafond bois sous solives bois | 114 | 114 | 0.25 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002674M | 13 | 0 | dpe arrêté 2012 facture logement | appartement | avant 1948 | 1900 | | NULL | 2013-09-17 00:00:00 | NULL | NULL | NULL | 46 | NULL | NULL | NULL | | | N | N | 0 | 0 | | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | simple vitrage | bois | | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | | NULL | | NULL | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002676O | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-09-17 00:00:00 | NULL | NULL | NULL | 27 | NULL | NULL | NULL | | | F | C | 369 | 20 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | simple vitrage | bois | | | NULL | 0 | 0 | 0 | 0 | 6.88 | NULL | non traversant | 4.7 | 4.7 | 0.52 | 0 | [ "est" ] | 0.341 | ITR | NULL | murs en béton banché | 0 | 40.14 | 13.29 | 40.14 | 0.5 | | | | non isole | dalle béton | 27.36 | 0 | 2 | NULL | | | | non isole | dalle béton | 27.36 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002677P | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1978-1982 | 1978 | | NULL | 2013-09-17 00:00:00 | NULL | NULL | NULL | 29 | NULL | NULL | NULL | | | E | B | 248 | 10 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « avant 1982 » | | double vitrage | bois | | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 0 | 0 | 0 | 6.16 | NULL | non traversant | 2.6 | NULL | 0.47 | 0 | [ "est" ] | 0.397 | ITI | NULL | murs en béton banché | 20 | 29.65 | 9.34 | 17.65 | 0.89 | | | | ITI | dalle béton | 29.45 | 0 | 0.89 | NULL | | | | ITI | dalle béton | 29.45 | 0 | 0.78 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002680J | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1983-1988 | 1987 | | NULL | 2013-09-17 00:00:00 | NULL | NULL | NULL | 128 | NULL | NULL | NULL | | | D | B | 182.28 | 9.09 | individuel | electricite | generateurs a effet joule | | bois | poele ou insert bois | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Extracteur mécanique sur conduit non modifié de ventilation naturelle existante | | double vitrage | métal avec rupture de pont thermique | argon ou krypton | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 5.88 | 16.04 | 3.18 | 18.32 | NULL | tout venant | 1.8 | 1.8 | 0.56 | 0 | [ "est", "nord", "ouest", "sud" ] | NULL | ITI | NULL | murs en briques creuses | 28 | 103.46 | 0 | 103.46 | 0.39 | | | | ITE | dalle béton | 128 | 128 | 0.35 | NULL | | | | ITI | dalle béton | 128 | 128 | 0.27 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002681K | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2013-09-17 00:00:00 | NULL | NULL | NULL | 69 | NULL | NULL | NULL | | | B | C | 77 | 18 | individuel | gaz | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 6.8 | 0 | 4.2 | 0 | NULL | est ouest | 1.8 | 2.2 | 0.38 | 0 | [ "nord", "ouest" ] | 0.224 | ITI | NULL | murs en béton banché | 22.5 | 69 | 38 | 69 | 0.4 | | | | ITI | dalle béton | 69.13 | 0 | 0.36 | NULL | | | | non isole | dalle béton | 69.13 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002684N | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1974 | | NULL | 2013-09-17 00:00:00 | NULL | NULL | NULL | 83 | NULL | NULL | NULL | | | D | C | 228 | 12 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.7 | 2.8 | 2.66 | 0 | | NULL | ITI | NULL | murs en pisé ou béton de terre stabilisé (à partir d'argile crue) | 70 | 160.14 | 0 | 160.14 | 0.47 | | | | ITI | dalle béton | 83 | 83 | 0.43 | NULL | | | | non isole | dalle béton | 90 | 90 | 2.5 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002685O | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2013-09-17 00:00:00 | NULL | NULL | NULL | 85 | NULL | NULL | NULL | | | D | E | 183 | 55 | individuel | fioul | chaudiere fioul standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere fioul standard | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | métal sans rupture de pont thermique | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 2.18 | 5.13 | 5.97 | 2.18 | NULL | tout venant | 3.4 | NULL | 0.49 | 0 | [ "est", "nord", "ouest", "sud" ] | 0.153 | non isole | NULL | murs en blocs de béton creux | 25 | 99.63 | 85.53 | 99.63 | 0.59 | | | | non isole | dalle béton | 85 | 85 | 0.37 | NULL | | | | ITE | dalle béton | 85 | 85 | 0.34 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002686P | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1978-1982 | 1978 | | NULL | 2013-09-17 00:00:00 | NULL | NULL | NULL | 137 | NULL | NULL | NULL | | | E | C | 244 | 15 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 3.66 | 12 | 5 | 3.08 | NULL | tout venant | 2.1 | 2.6 | 0.44 | 1 | [ "est", "nord", "ouest", "sud" ] | 0.13 | non isole | NULL | murs en blocs de béton creux | 20 | 159.26 | 159.26 | 159.26 | 2 | | | | non isole | | 100 | 100 | 0.37 | NULL | | | | non isole | combles aménagés sous rampant | 85 | 85 | 0.44 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002687Q | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1983-1988 | 1983 | | NULL | 2013-09-18 00:00:00 | NULL | NULL | NULL | 370 | NULL | NULL | NULL | | | C | D | 111 | 28 | individuel | fioul | chaudiere fioul standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere fioul standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | métal sans rupture de pont thermique | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 1.77 | 45.26 | 11 | 14.38 | NULL | tout venant | 3.4 | NULL | 0.54 | 1 | [ "est", "nord", "ouest", "sud" ] | 0.202 | ITI | NULL | murs en briques pleines doubles avec lame d'air | 45 | 304.98 | 285.38 | 304.98 | 0.78 | | | | ITE | plancher lourd type entrevous terre-cuite, poutrelles béton | 208 | 208 | 0.78 | NULL | | | | ITI | combles aménagés sous rampant | 190 | 190 | 0.34 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002688R | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1963 | | NULL | 2013-09-18 00:00:00 | NULL | NULL | NULL | 95 | NULL | NULL | NULL | | | D | B | 195.44 | 8.58 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation naturelle par conduit avec entrées d’air hygroréglables | | double vitrage | métal avec rupture de pont thermique | argon ou krypton | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 2.76 | 9.14 | 5.38 | 2.76 | NULL | tout venant | 2.2 | 2.7 | 0.48 | 0 | [ "est", "nord", "ouest", "sud" ] | 0.195 | ITI | NULL | murs en briques creuses | 20 | 82.84 | 82.84 | 82.84 | 0.4 | | | | | | NULL | NULL | NULL | NULL | | | | | plafond lourd type entrevous terre-cuite, poutrelles béton | 106.42 | 106.42 | 0.25 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002691L | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1989-2000 | 1997 | | NULL | 2013-09-18 00:00:00 | NULL | NULL | NULL | 18 | NULL | NULL | NULL | | | E | C | 290.17 | 12.44 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 0 | 4.23 | 0 | 0 | NULL | non traversant | 2.2 | 2.8 | 0.44 | 1 | [ "sud" ] | 0.178 | ITI | NULL | murs en béton banché | 20 | 24.47 | 19.52 | 24.47 | 0.35 | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002692M | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1964 | | NULL | 2013-09-18 00:00:00 | NULL | NULL | NULL | 87 | NULL | NULL | NULL | | | C | A | 145.1 | 4.13 | individuel | electricite | pac air/air | | electricite | chaudiere electrique | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | métal avec rupture de pont thermique | argon ou krypton | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 5.87 | 4.02 | 0 | 0 | NULL | tout venant | 1.1 | NULL | 0.48 | 1 | [ "indetermine", "nord", "sud" ] | 0.257 | ITI | NULL | murs en blocs de béton creux | 20 | 70.86 | 49.56 | 70.86 | 0.4 | | | | ITI | dalle béton | 87.3 | 87.3 | 0.36 | NULL | | | | ITE | dalle béton | 92.64 | 92.64 | 0.17 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002693N | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1958 | | NULL | 2013-09-18 00:00:00 | NULL | NULL | NULL | 97 | NULL | NULL | NULL | | | D | F | 222.8 | 66.84 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | gaz | chaudiere gaz standard | | 1 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 1.92 | 1.64 | 12.66 | NULL | non traversant | 3.5 | 4.7 | 0.52 | 0 | [ "est", "ouest", "sud" ] | 0.203 | non isole | NULL | murs en blocs de béton pleins | 30 | 90.26 | 63.79 | 90.26 | 2 | | | | non isole | dalle béton | 96.5 | 96.5 | 0.34 | NULL | | | | ITI | dalle béton | 96.5 | 96.5 | 0.4 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002694O | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1978-1982 | 1982 | | NULL | 2013-09-18 00:00:00 | NULL | NULL | NULL | 97 | NULL | NULL | NULL | | | C | D | 125.52 | 34.39 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation hybride | | double vitrage | métal | air sec | | NULL | 0 | 3.02 | 7.44 | 0 | 0 | NULL | nord sud | 3.2 | 3.2 | NULL | 0 | [ "nord", "sud" ] | 0.105 | ITI | NULL | murs en béton banché | 20 | 89.41 | 89.41 | 89.41 | 0.35 | | | | non isole | voutains en briques ou moellons | 100.09 | 100.09 | 0.8 | NULL | | | | ITI | plafond entre solives bois avec ou sans remplissage | 100.09 | 100.09 | 0.17 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002696Q | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1963 | | NULL | 2013-09-18 00:00:00 | NULL | NULL | NULL | 89 | NULL | NULL | NULL | | | D | B | 223.82 | 10.35 | individuel | electricite | generateurs a effet joule | | bois | poele ou insert bois | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation naturelle par conduit avec entrées d’air hygroréglables | | double vitrage | pvc | argon ou krypton | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 8.11 | 6.98 | 1.97 | NULL | tout venant | 2.2 | 2.2 | 0.48 | 1 | [ "est", "ouest", "sud" ] | 0.157 | ITI | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 50 | 91.53 | 91.53 | 91.53 | 0.4 | | | | ITE | plancher lourd type entrevous terre-cuite, poutrelles béton | 94.09 | 94.09 | 0.36 | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002698S | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2006-2012 | 2006 | | NULL | 2013-09-18 00:00:00 | NULL | NULL | NULL | 80 | NULL | NULL | NULL | | | C | B | 115.45 | 6.23 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ecs thermodynamique electrique(pac ou ballon) | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | argon ou krypton | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 3.44 | 7.98 | 0 | 0 | NULL | nord sud | 1.9 | 2.2 | 0.38 | 0 | [ "nord", "sud" ] | 0.311 | ITI | NULL | | 0 | 25.34 | 25.34 | 25.34 | 0.4 | | | | ITE | dalle béton | 40.61 | 40.61 | 0.36 | NULL | | | | ITE | plafond entre solives bois avec ou sans remplissage | 40.61 | 40.61 | 0.25 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002700C | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2013-09-18 00:00:00 | NULL | NULL | NULL | 160 | NULL | NULL | NULL | | | D | E | 229 | 53 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | | NULL | 0 | 0 | 3 | 18 | 6.5 | NULL | tout venant | 4.7 | 4.7 | 0.52 | 0 | [ "est", "ouest", "sud" ] | 0.153 | non isole | NULL | murs en blocs de béton creux | 25 | 152.5 | 152.5 | 152.5 | 2 | | | | non isole | | 100 | 100 | 0.37 | NULL | | | | ITI | plafond bois sous solives bois | 100 | 100 | 0.27 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002702E | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1960 | | NULL | 2013-09-18 00:00:00 | NULL | NULL | NULL | 75 | NULL | NULL | NULL | | | D | C | 153.55 | 11.44 | individuel | electricite | pac air/air | | gaz | chaudiere gaz standard | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | métal sans rupture de pont thermique | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 0 | 8.03 | 4.98 | NULL | est ouest | 3.1 | 4 | 0.57 | 1 | [ "est", "ouest" ] | 0.474 | non isole | NULL | murs en béton banché | 20 | 23.56 | 14.45 | 23.56 | 2 | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002703F | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-09-18 00:00:00 | NULL | NULL | NULL | 43 | NULL | NULL | NULL | | | E | C | 301 | 17 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | argon ou krypton | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 4.05 | 0.77 | 0 | 0 | NULL | non traversant | 2.1 | 2.6 | 0.44 | 0 | [ "nord", "sud" ] | 0.223 | ITI | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 50 | 80.72 | 16.78 | 17.93 | 2 | | | | ITI | plancher avec ou sans remplissage | 42.58 | 0 | 0.87 | NULL | | | | ITI | combles aménagés sous rampant | 42.58 | 42.58 | 0.24 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002704G | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-09-18 00:00:00 | NULL | NULL | NULL | 63 | NULL | NULL | NULL | | | E | C | 231 | 11 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | métal sans rupture de pont thermique | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 1.97 | 4.45 | 3.31 | 0 | NULL | tout venant | 2.2 | NULL | 0.49 | 1 | [ "nord", "ouest", "sud" ] | 0.112 | non isole | NULL | murs en béton banché | 30 | 99.12 | 77.1 | 99.12 | 0.98 | | | | non isole | dalle béton | 63.05 | 0 | 2 | NULL | | | | non isole | dalle béton | 63.05 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002705H | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-09-18 00:00:00 | NULL | NULL | NULL | 22 | NULL | NULL | NULL | | | F | D | 396 | 27 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 1.62 | 3.52 | 0 | 0 | NULL | nord sud | 3.4 | 4.7 | 0.52 | 0 | [ "nord", "sud" ] | 0.169 | non isole | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 55 | 42.01 | 25.29 | 42.01 | 1.9 | | | | non isole | voutains sur solives métalliques | 22.3 | 22.3 | 1.75 | NULL | | | | non isole | plafond entre solives bois avec ou sans remplissage | 22.3 | 0 | 1.2 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002706I | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1974 | | NULL | 2014-04-04 00:00:00 | NULL | NULL | NULL | 36 | NULL | NULL | NULL | | | D | B | 189 | 7 | individuel | electricite | chaudiere electrique | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.8 | 2.7 | 1.38 | 0 | | NULL | non isole | NULL | béton cellulaire | 27.5 | 51.25 | 0 | 51.25 | 0.42 | | | | | | NULL | NULL | NULL | NULL | | | | ITE | plafond bois sur solives bois | 36 | 36 | 0.61 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002708K | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1983-1988 | 1988 | | NULL | 2013-09-18 00:00:00 | NULL | NULL | NULL | 111 | NULL | NULL | NULL | | | C | A | 115 | 4 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « avant 1982 » | | double vitrage | métal sans rupture de pont thermique | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.8 | 4.5 | 5.51 | 0 | | NULL | non isole | NULL | murs en béton banché | 20 | 55.88 | 0 | 55.88 | 0.78 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002713G | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1954 | | NULL | 2013-09-18 00:00:00 | NULL | NULL | NULL | 63 | NULL | NULL | NULL | | | D | E | 186.55 | 43.65 | individuel | gaz | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | simple vitrage | bois | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 17.29 | 7.36 | 0 | 0 | NULL | nord sud | 1.4 | 1.4 | 0.56 | 1 | [ "nord", "sud" ] | 0.583 | non isole | NULL | murs en blocs de béton pleins | 33 | 58.54 | 17.65 | 58.54 | 2 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002715I | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2001-2005 | 2004 | | NULL | 2013-09-18 00:00:00 | NULL | NULL | NULL | 154 | NULL | NULL | NULL | | | C | A | 133 | 5 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | métal avec rupture de pont thermique | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 3.49 | 15.51 | 0 | 9.16 | NULL | tout venant | 2.5 | 2.8 | 0.48 | 1 | [ "est", "nord", "sud" ] | 0.177 | non isole | NULL | monomur terre cuite | 30 | 173.22 | 130.93 | 153.12 | 0.23 | | | | ITE | plancher à entrevous isolant | 90.72 | 90.72 | 0.45 | NULL | | | | ITI | plafond bois sous solives bois | 90.72 | 90.72 | 0.38 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002719M | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 2000 | | NULL | 2013-09-18 00:00:00 | NULL | NULL | NULL | 170 | NULL | NULL | NULL | | | C | D | 129 | 24 | individuel | gaz | chaudiere gaz standard | | bois | poele ou insert bois | | 0 | NULL | NULL | | | | | | chauffe-eau gaz independant | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | bois | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 3.1 | 3.1 | 2.38 | 0 | | 0.031 | ITI | NULL | murs en blocs de béton creux | 20 | 157.6 | 105.5 | 157.6 | 0.42 | | | | ITI | dalle béton | 170 | 170 | 0.61 | NULL | | | | | plafond entre solives bois avec ou sans remplissage | 170 | 170 | 0.3 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002721F | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1978-1982 | 1982 | | NULL | 2013-09-18 00:00:00 | NULL | NULL | NULL | 178 | NULL | NULL | NULL | | | D | D | 155 | 25 | individuel | fioul | chaudiere fioul standard | | bois | poele ou insert bois | | 0 | NULL | NULL | | | | individuel | | chaudiere fioul standard | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2 | 2.2 | 0.55 | 1 | | 0.189 | ITI | NULL | murs en blocs de béton creux | 20 | 187.48 | 91 | 187.48 | 0.3 | | | | ITE | plancher à entrevous isolant | 178 | 178 | 0.14 | NULL | | | | ITE | plafond avec ou sans remplissage | 178 | 178 | 0.18 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002722G | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2013-09-18 00:00:00 | NULL | NULL | NULL | 75 | NULL | NULL | NULL | | | F | G | 372 | 87 | individuel | fioul | chaudiere fioul standard | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 6.96 | 7.37 | 2.68 | NULL | tout venant | 3.5 | 4.8 | 0.56 | 0 | [ "est", "ouest", "sud" ] | 0.196 | ITI | NULL | murs en briques pleines doubles avec lame d'air | 30 | 69.79 | 69.79 | 69.79 | 2 | | | | non isole | plancher lourd type entrevous terre-cuite, poutrelles béton | 75.11 | 75.11 | 2 | NULL | | | | ITI | dalle béton | 75.11 | 75.11 | 0.34 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002724I | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1989 | | NULL | 2013-09-18 00:00:00 | NULL | NULL | NULL | 115 | NULL | NULL | NULL | | | D | E | 230 | 41 | individuel | electricite | pac air/air | | gaz | chaudiere gaz condensation | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | gaz | chaudiere gaz condensation | | 1 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | bois | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 5.5 | 7 | 0.3 | 0 | NULL | tout venant | 2.4 | 2.9 | 0.47 | 1 | [ "nord", "ouest", "sud" ] | 0.029 | ITI | NULL | murs en blocs de béton creux | 20 | 423.3 | 423.3 | 423.3 | 0.5 | | | | ITE | plancher lourd type entrevous terre-cuite, poutrelles béton | 130 | 130 | 0.61 | NULL | | | | ITI | plafond bois sous solives bois | 130 | 130 | 0.3 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002725J | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 2000 | | NULL | 2013-09-19 00:00:00 | NULL | NULL | NULL | 205 | NULL | NULL | NULL | | | D | D | 189 | 24 | individuel | fioul | chaudiere fioul standard | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.7 | 2.6 | 2.68 | 0 | | NULL | ITI | NULL | murs en blocs de béton creux | NULL | 226.35 | 0 | 226.35 | NULL | | | | ITI | dalle béton | 177.64 | 177.64 | 0.19 | NULL | | | | ITI | combles aménagés sous rampant | 177.64 | 177.64 | 0.19 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1002727L | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1989-2000 | 1989 | | NULL | 2013-09-19 00:00:00 | NULL | NULL | NULL | 62 | NULL | NULL | NULL | | | D | B | 202 | 9 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 14.3 | 0 | 2.3 | NULL | non traversant | 2.2 | 2.7 | 0.44 | 1 | [ "est", "sud" ] | 0.604 | ITI | NULL | murs en briques pleines doubles avec lame d'air | 35 | 12.1 | 10.9 | 12.1 | 0.5 | | | | ITE | dalle béton | 62.26 | 62.26 | 0.61 | NULL | | | | non isole | dalle béton | 62.26 | 0 | 2.5 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |