| 1313V1001205B | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2001-2005 | 2002 | | NULL | 2013-07-11 00:00:00 | NULL | NULL | NULL | 19 | NULL | NULL | NULL | | | E | B | 266.76 | 10.43 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 1.21 | 0 | 0 | NULL | non traversant | 2.2 | 2.7 | 0.44 | 0 | [ "sud" ] | 0.158 | ITI | NULL | murs en béton banché | 28 | 32.63 | 6.43 | 32.63 | 0.47 | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001207D | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1978-1982 | 1978 | | NULL | 2013-07-11 00:00:00 | NULL | NULL | NULL | 104 | NULL | NULL | NULL | | | C | D | 122 | 28 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 6.83 | 11.52 | 0 | 0 | NULL | nord sud | 2.4 | 2.6 | 0.44 | 0 | [ "nord", "sud" ] | 0.294 | non isole | NULL | murs en béton banché | 22.5 | 51.96 | 43.96 | 51.96 | 2 | | | | ITE | plancher lourd type entrevous terre-cuite, poutrelles béton | 57 | 57 | 1 | NULL | | | | ITI | plafond entre solives bois avec ou sans remplissage | 58 | 58 | 0.22 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001208E | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1950 | | NULL | 2013-07-11 00:00:00 | NULL | NULL | NULL | 75 | NULL | NULL | NULL | | | F | G | 361.27 | 84.53 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 2.42 | 2.29 | 0 | 0 | NULL | nord sud | 1.6 | 1.6 | 0.48 | 0 | [ "nord", "sud" ] | 0.05 | non isole | NULL | murs en blocs de béton creux | 20 | 171.49 | 90 | 171.49 | 2 | | | | non isole | | 54 | 54 | 0.35 | NULL | | | | ITI | plafond avec ou sans remplissage sous combles | 54 | 54 | 0.26 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001209F | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2013-07-11 00:00:00 | NULL | NULL | NULL | 68 | NULL | NULL | NULL | | | D | B | 173 | 8 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.7 | 2.6 | 2.99 | 0 | | NULL | non isole | NULL | murs en béton banché | 20 | 47.9 | 0 | 47.9 | 0.4 | | | | | dalle béton | 67.89 | 67.89 | 0.36 | NULL | | | | | dalle béton | 67.89 | 67.89 | 0.27 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001212@ | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1995 | | NULL | 2013-07-11 00:00:00 | NULL | NULL | NULL | 166 | NULL | NULL | NULL | | | B | C | 83.36 | 13.29 | individuel | electricite | pac eau/eau | | gaz | chaudiere gaz standard | | 0 | NULL | NULL | electricite | pac air/air | | collectif | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 1.51 | 12.67 | 7.87 | 6.15 | NULL | tout venant | 2.6 | NULL | 0.43 | 1 | [ "est", "nord", "ouest", "sud" ] | 0.131 | ITI | NULL | murs en blocs de béton pleins | 40 | 209.81 | 187.28 | 209.81 | 0.5 | | | | ITI | dalle béton | 106.05 | 106.05 | 0.59 | NULL | | | | ITI | combles aménagés sous rampant | 71.82 | 71.82 | 0.29 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001213A | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1970 | | NULL | 2013-07-11 00:00:00 | NULL | NULL | NULL | 86 | NULL | NULL | NULL | | | E | E | 267 | 55 | individuel | gaz | chaudiere gaz standard | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | argon ou krypton | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.6 | 2.6 | 6.49 | 0 | | 0.206 | ITI | NULL | murs en blocs de béton creux | 20 | 98.61 | 21.65 | 98.61 | 1.1 | | | | non isole | plancher lourd type entrevous terre-cuite, poutrelles béton | 86.18 | 86.18 | 2 | NULL | | | | ITE | plafond lourd type entrevous terre-cuite, poutrelles béton | 86.18 | 86.18 | 1 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001215C | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2010 | | NULL | 2013-07-11 00:00:00 | NULL | NULL | NULL | 36 | NULL | NULL | NULL | | | C | A | 132.87 | 3.53 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0 | 5.92 | 0 | 2.52 | NULL | 90° | 1.5 | 1.5 | 0.47 | 0 | [ "est", "sud" ] | NULL | ITI | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 35 | 39.67 | 0 | 39.67 | 0.34 | | | | | | NULL | NULL | NULL | NULL | | | | ITI | plafond en plaque de plâtre | 36 | 36 | 0.15 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001216D | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1978-1982 | 1981 | | NULL | 2013-07-11 00:00:00 | NULL | NULL | NULL | 83 | NULL | NULL | NULL | | | E | C | 280 | 16 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 2.32 | 6.01 | 0 | 2.34 | NULL | tout venant | 2.4 | 2.9 | 0.47 | 0 | [ "est", "nord", "sud" ] | 0.084 | ITI | NULL | murs en blocs de béton creux | 20 | 132.33 | 116.08 | 132.33 | 0.89 | | | | non isole | dalle béton | 83 | 83 | 0.37 | NULL | | | | ITI | plafond bois sous solives bois | 83 | 83 | 0.44 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001218F | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-07-11 00:00:00 | NULL | NULL | NULL | 156 | NULL | NULL | NULL | | | E | E | 232 | 47 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0 | 0 | 15 | 15 | NULL | est ouest | 3.5 | 4.7 | 0.52 | 0 | [ "est", "ouest" ] | 0.357 | non isole | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 40 | 104 | 54 | 54 | 2 | | | | non isole | dalle béton | 156.01 | 156.01 | 2 | NULL | | | | non isole | dalle béton | 156.01 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001219G | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2013-07-11 00:00:00 | NULL | NULL | NULL | 86 | NULL | NULL | NULL | | | C | A | 99 | 3 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 6.12 | 6.53 | 0 | 0 | NULL | nord sud | 2.3 | 2.8 | 0.51 | 1 | [ "nord", "sud" ] | 0.472 | ITI | NULL | murs en béton banché | 20 | 22.02 | 14.15 | 22.02 | 0.4 | | | | | dalle béton | 85.91 | 0 | 0.36 | NULL | | | | ITI | dalle béton | 85.91 | 0 | 0.25 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001223B | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1965 | | NULL | 2013-07-11 00:00:00 | NULL | NULL | NULL | 91 | NULL | NULL | NULL | | | D | E | 224.82 | 41.68 | individuel | fioul | chaudiere fioul standard | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 4.74 | 4 | 9.38 | 0 | NULL | tout venant | 1.5 | 1.5 | 0.44 | 0 | [ "nord", "ouest", "sud" ] | NULL | ITI | NULL | murs en blocs de béton creux | 25 | 82.24 | 0 | 82.24 | 0.7 | | | | non isole | dalle béton | 23.9 | 23.9 | 2 | NULL | | | | ITE | dalle béton | 93.6 | 93.6 | 0.19 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001224C | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2013-07-12 00:00:00 | NULL | NULL | NULL | 155 | NULL | NULL | NULL | | | E | C | 273 | 12 | individuel | electricite | generateurs a effet joule | | bois | poele ou insert bois | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 19.3 | 5.7 | 14.5 | 1.6 | NULL | tout venant | 3.4 | 2.6 | 0.44 | 1 | [ "est", "nord", "ouest", "sud" ] | 0.342 | ITI | NULL | murs en briques pleines doubles avec lame d'air | 20 | 78.9 | 78.9 | 78.9 | 2 | | | | ITE | | 97 | 97 | 0.37 | NULL | | | | ITI | plafond avec ou sans remplissage sous combles | 97 | 97 | 0.16 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001225D | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1978-1982 | 1978 | | NULL | 2013-07-12 00:00:00 | NULL | NULL | NULL | 70 | NULL | NULL | NULL | | | E | C | 233 | 12 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Extracteur mécanique sur conduit non modifié de ventilation naturelle existante | | double vitrage | métal sans rupture de pont thermique | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0 | 0 | 7 | 4.6 | NULL | est ouest | 3.8 | NULL | 0.49 | 1 | [ "est", "ouest" ] | 0.317 | ITI | NULL | murs en briques pleines doubles avec lame d'air | 30 | 28.5 | 25 | 28.5 | 0.89 | | | | non isole | dalle béton | 80.61 | 0 | 2 | NULL | | | | non isole | dalle béton | 80.61 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001227F | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1989-2000 | 1989 | | NULL | 2013-07-12 00:00:00 | NULL | NULL | NULL | 54 | NULL | NULL | NULL | | | E | C | 274 | 15 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 1 | 9 | 0 | NULL | non traversant | 2.2 | 2.7 | 0.44 | 0 | [ "ouest", "sud" ] | 0.189 | ITI | NULL | murs en blocs de béton creux | 20 | 43 | 43 | 43 | 0.5 | | | | non isole | plancher lourd type entrevous terre-cuite, poutrelles béton | 54 | 14 | 2 | NULL | | | | | plafond lourd type entrevous terre-cuite, poutrelles béton | 54 | 0 | 0.39 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001228 | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1978-1982 | 1982 | | NULL | 2013-07-12 00:00:00 | NULL | NULL | NULL | 37 | NULL | NULL | NULL | | | D | B | 180.07 | 6.91 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | métal sans rupture de pont thermique | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0.75 | 4.77 | 0.3 | 0 | NULL | non traversant | 3.1 | 4.3 | 0.57 | 0 | [ "nord", "ouest", "sud" ] | 0.22 | ITI | NULL | | 0 | 20.61 | 20.61 | 20.61 | 0.89 | | | | non isole | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | combles aménagés sous rampant | 35.7 | 35.7 | 0.44 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001229H | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1978-1982 | 1982 | | NULL | 2013-07-12 00:00:00 | NULL | NULL | NULL | 37 | NULL | NULL | NULL | | | D | B | 180.07 | 6.91 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | métal sans rupture de pont thermique | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0.75 | 4.77 | 0.3 | 0 | NULL | non traversant | 3.1 | 4.3 | 0.57 | 0 | [ "nord", "ouest", "sud" ] | 0.22 | ITI | NULL | | 0 | 20.61 | 20.61 | 20.61 | 0.89 | | | | non isole | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | combles aménagés sous rampant | 35.7 | 35.7 | 0.44 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001230@ | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2001-2005 | 2004 | | NULL | 2013-07-12 00:00:00 | NULL | NULL | NULL | 133 | NULL | NULL | NULL | | | C | D | 91.17 | 21.33 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | collectif | | ecs solaire | | gaz | chaudiere gaz condensation | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | métal avec rupture de pont thermique | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 1.6 | 19.71 | 2.02 | 12.77 | NULL | tout venant | 3.8 | 3.8 | 0.52 | 1 | [ "est", "indetermine", "nord", "ouest", "sud" ] | 0.21 | ITI | NULL | murs en blocs de béton creux | 20 | 140.43 | 140.43 | 140.43 | 0.35 | | | | ITE | plancher avec ou sans remplissage | 90 | 90 | 0.71 | NULL | | | | ITI | plafond avec ou sans remplissage | 90 | 90 | 0.31 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001233C | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1950 | | NULL | 2013-07-12 00:00:00 | NULL | NULL | NULL | 75 | NULL | NULL | NULL | | | F | G | 361.27 | 84.53 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 2.42 | 2.29 | 0 | 0 | NULL | nord sud | 1.6 | 1.6 | 0.48 | 0 | [ "nord", "sud" ] | 0.05 | non isole | NULL | murs en blocs de béton creux | 20 | 171.49 | 90 | 171.49 | 2 | | | | non isole | | 54 | 54 | 0.35 | NULL | | | | ITI | plafond avec ou sans remplissage sous combles | 54 | 54 | 0.26 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001234D | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1983-1988 | 1986 | | NULL | 2013-07-12 00:00:00 | NULL | NULL | NULL | 75 | NULL | NULL | NULL | | | C | D | 141.29 | 30.81 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ecs solaire | | gaz | chaudiere gaz standard | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | argon ou krypton | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 3.12 | 4.3 | 0 | 3.26 | NULL | tout venant | 1.3 | NULL | 0.38 | 1 | [ "est", "nord", "sud" ] | 0.109 | ITI | NULL | murs en blocs de béton creux | 20 | 87.33 | 87.33 | 87.33 | 0.78 | | | | non isole | dalle béton | 2.9 | 2.9 | 0.61 | NULL | | | | ITI | plafond en plaque de plâtre | 41.5 | 41.5 | 0.16 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001236 | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1974 | | NULL | 2013-07-12 00:00:00 | NULL | NULL | NULL | 21 | NULL | NULL | NULL | | | E | C | 295 | 15 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | argon ou krypton | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.6 | 2.6 | 3.27 | 0 | | NULL | | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 35 | 25.84 | 0 | 25.84 | 2 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001238H | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1974 | | NULL | 2013-07-12 00:00:00 | NULL | NULL | NULL | 21 | NULL | NULL | NULL | | | E | C | 295 | 15 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | argon ou krypton | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.6 | 2.6 | 3.27 | 0 | | NULL | | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 35 | 25.84 | 0 | 25.84 | 2 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001240A | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1991 | | NULL | 2013-07-12 00:00:00 | NULL | NULL | NULL | 160 | NULL | NULL | NULL | | | B | C | 80 | 18 | individuel | gaz | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | métal sans rupture de pont thermique | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 15.96 | 2.64 | 6.16 | NULL | tout venant | 3.3 | NULL | 0.57 | 0 | [ "est", "ouest", "sud" ] | 0.152 | ITR | NULL | murs en blocs de béton creux | 20 | 153.34 | 138.34 | 153.34 | 0.54 | | | | ITI | plancher lourd type entrevous terre-cuite, poutrelles béton | 105 | 105 | 0.61 | NULL | | | | ITI | plafond bois sous solives bois | 120 | 120 | 0.29 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001242C | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1960 | | NULL | 2013-07-12 00:00:00 | NULL | NULL | NULL | 187 | NULL | NULL | NULL | | | E | F | 268.88 | 80.66 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | collectif | | ecs solaire | | gaz | chaudiere gaz standard | | 1 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 3.5 | 8.32 | 8.26 | 3.82 | NULL | tout venant | 2.2 | NULL | 0.38 | 0 | [ "est", "indetermine", "nord", "ouest", "sud" ] | 0.14 | non isole | NULL | murs en blocs de béton creux | 25 | 184.15 | 160.84 | 184.15 | 2 | | | | non isole | dalle béton | 187 | 187 | 2 | NULL | | | | non isole | plafond bois sous solives bois | 193.83 | 193.83 | 0.4 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001243D | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 2000 | | NULL | 2013-07-12 00:00:00 | NULL | NULL | NULL | 95 | NULL | NULL | NULL | | | C | D | 111 | 26 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 3.1 | 3.1 | 3.6 | 0 | | NULL | ITI+ITR | NULL | murs en briques creuses | NULL | 112.5 | 0 | 112.5 | NULL | | | | ITE | dalle béton | 94.55 | 94.55 | 0.61 | NULL | | | | ITE | dalle béton | 94.55 | 94.55 | 0.19 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001244E | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1989-2000 | 2000 | | NULL | 2013-07-12 00:00:00 | NULL | NULL | NULL | 52 | NULL | NULL | NULL | | | D | B | 187.17 | 7.64 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | argon ou krypton | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 6.3 | 0 | 2.79 | NULL | 90° | 1.9 | NULL | 0.39 | 1 | [ "est", "sud" ] | 0.219 | ITI | NULL | murs en béton banché | 20 | 47.63 | 32.4 | 47.63 | 0.43 | | | | non isole | plancher avec ou sans remplissage | 51.57 | 51.57 | 0.37 | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001245F | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-07-12 00:00:00 | NULL | NULL | NULL | 29 | NULL | NULL | NULL | | | F | D | 398 | 21 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 2.6 | 0 | 0 | 0 | NULL | non traversant | 3.4 | 4.7 | 0.52 | 0 | [ "nord" ] | 0.155 | ITR | NULL | | 0 | 75.59 | 14.16 | 28.8 | 0.98 | | | | | plancher avec ou sans remplissage | 28.83 | 0 | 1.45 | NULL | | | | | plafond avec ou sans remplissage | 28.83 | 0 | 1.45 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001246G | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-07-12 00:00:00 | NULL | NULL | NULL | 41 | NULL | NULL | NULL | | | E | C | 306 | 16 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 4.62 | 0 | 0 | NULL | non traversant | 3.4 | 4.7 | 0.52 | 0 | [ "sud" ] | 0.226 | ITI | NULL | | 0 | 97.68 | 15.82 | 22.17 | 2 | | | | | plancher avec ou sans remplissage | 41.12 | 0 | 1.45 | NULL | | | | | plafond avec ou sans remplissage | 41.12 | 0 | 1.45 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001247H | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-07-12 00:00:00 | NULL | NULL | NULL | 81 | NULL | NULL | NULL | | | D | C | 220 | 11 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | métal avec rupture de pont thermique | argon ou krypton | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 5.1 | 5.7 | NULL | est ouest | 3.2 | 3.2 | 0.52 | 0 | [ "est", "ouest" ] | 0.245 | ITR | NULL | | 0 | 75.37 | 33.25 | 37.45 | 0.98 | | | | ITI | plancher avec ou sans remplissage | 81.42 | 0 | 0.87 | NULL | | | | | plafond avec ou sans remplissage | 81.82 | 0 | 1.45 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001249J | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-07-12 00:00:00 | NULL | NULL | NULL | 48 | NULL | NULL | NULL | | | E | D | 238 | 22 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | argon ou krypton | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 1.94 | 8.28 | 0 | 0 | NULL | non traversant | 2.2 | 2.6 | 0.44 | 0 | [ "nord", "sud" ] | 0.362 | ITI | NULL | | 0 | 67.03 | 17.98 | 25.93 | 2 | | | | ITI | plancher avec ou sans remplissage | 48.46 | 0 | 0.87 | NULL | | | | | plafond avec ou sans remplissage | 48.46 | 0 | 1.45 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001251C | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1978-1982 | 1981 | | NULL | 2013-07-12 00:00:00 | NULL | NULL | NULL | 132 | NULL | NULL | NULL | | | C | A | 99.98 | 3.98 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | bois | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 21.26 | 13.59 | 0 | 9.04 | NULL | tout venant | 1.4 | 1.4 | 0.5 | 0 | [ "est", "nord", "sud" ] | NULL | ITI | NULL | murs en blocs de béton creux | 23 | 59.73 | 0 | 59.73 | 0.42 | | | | ITE | plancher à entrevous isolant | 67.5 | 67.5 | 0.89 | NULL | | | | ITI | plafond en plaque de plâtre | 67.5 | 67.5 | 0.24 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001252D | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2013-07-13 00:00:00 | NULL | NULL | NULL | 77 | NULL | NULL | NULL | | | D | B | 211 | 10 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0 | 1.34 | 6.03 | 2.68 | NULL | tout venant | 2.5 | 3 | 0.47 | 0 | [ "est", "ouest", "sud" ] | 0.154 | ITI | NULL | murs en blocs de béton creux | 23 | 72.25 | 55.25 | 72.25 | 0.61 | | | | non isole | | 77 | 77 | 2 | NULL | | | | ITI | plafond bois sous solives bois | 77 | 77 | 0.3 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001253E | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1978-1982 | 1980 | | NULL | 2013-07-13 00:00:00 | NULL | NULL | NULL | 210 | NULL | NULL | NULL | | | E | C | 281.79 | 16.19 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 2.32 | 40.27 | 0 | 9.02 | NULL | non traversant | 1.6 | 1.6 | 0.43 | 1 | [ "est", "nord", "sud" ] | NULL | ITI | NULL | murs en blocs de béton creux | 25 | 261.07 | 0 | 261.07 | 0.41 | | | | ITE | dalle béton | 143.1 | 143.1 | 0.35 | NULL | | | | ITE | combles aménagés sous rampant | 155.39 | 155.39 | 0.29 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001254F | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2006-2012 | 2006 | | NULL | 2013-07-13 00:00:00 | NULL | NULL | NULL | 90 | NULL | NULL | NULL | | | D | B | 197 | 10 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | argon ou krypton | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.7 | 2.6 | 2.74 | 0 | | NULL | ITI | NULL | murs en blocs de béton creux | 20 | 140 | 0 | 140 | 0.42 | | | | ITI | plancher lourd type entrevous terre-cuite, poutrelles béton | 90 | 90 | 0.27 | NULL | | | | non isole | plafond bois sous solives bois | 45 | 45 | 2.3 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001256H | 13 | 0 | dpe arrêté 2012 facture logement | appartement | avant 1948 | 1940 | | NULL | 2013-07-13 00:00:00 | NULL | NULL | NULL | 87 | NULL | NULL | NULL | | | N | N | 0 | 0 | | electricite | chaudiere electrique | | | | | 0 | NULL | NULL | | | | | | chaudiere electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | simple vitrage | bois | | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | | NULL | | NULL | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001258J | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1978-1982 | 1978 | | NULL | 2013-07-13 00:00:00 | NULL | NULL | NULL | 86 | NULL | NULL | NULL | | | E | C | 325 | 18 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | bois | air sec | | NULL | 0 | 5.2 | 6 | 0 | 0 | NULL | nord sud | 3.1 | 3.1 | 0.47 | 0 | [ "nord", "sud" ] | 0.224 | ITI | NULL | murs en blocs de béton creux | 20 | 38.8 | 38.8 | 38.8 | 0.89 | | | | non isole | plancher lourd type entrevous terre-cuite, poutrelles béton | 86 | 86 | 2 | NULL | | | | ITI | dalle béton | 89 | 89 | 0.44 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001259K | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1989-2000 | 2000 | | NULL | 2013-07-14 00:00:00 | NULL | NULL | NULL | 18 | NULL | NULL | NULL | | | D | B | 198 | 6 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | | pvc | | | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en béton banché | 30 | 7.5 | 0 | 7.5 | 0.5 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001261D | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2013-07-14 00:00:00 | NULL | NULL | NULL | 100 | NULL | NULL | NULL | | | E | C | 306 | 16 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | métal sans rupture de pont thermique | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 5.13 | 6.6 | 6.16 | 0.3 | NULL | tout venant | 3.1 | NULL | 0.54 | 1 | [ "est", "nord", "ouest", "sud" ] | 0.172 | non isole | NULL | murs en blocs de béton creux | 20 | 124.81 | 87.81 | 124.81 | 2 | | | | non isole | dalle béton | 75 | 75 | 0.37 | NULL | | | | ITI | plafond lourd type entrevous terre-cuite, poutrelles béton | 75 | 75 | 0.43 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001263F | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1989 | | NULL | 2013-07-14 00:00:00 | NULL | NULL | NULL | 88 | NULL | NULL | NULL | | | D | B | 175 | 7 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation hybride avec entrées d’air hygroréglables | | double vitrage | bois | argon ou krypton | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 5.88 | 9.17 | NULL | est ouest | 2.2 | 2.8 | 0.47 | 0 | [ "est", "ouest" ] | 0.137 | ITI | NULL | murs en blocs de béton creux | 20 | 94.68 | 94.68 | 94.68 | 0.22 | | | | ITE | | 88 | 88 | 0.35 | NULL | | | | ITI | dalle béton | 88 | 88 | 0.19 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001264G | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2013-07-14 00:00:00 | NULL | NULL | NULL | 42 | NULL | NULL | NULL | | | G | D | 514 | 32 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 4 | 4 | 2 | 0 | NULL | tout venant | 2.1 | 2.6 | 0.44 | 0 | [ "nord", "ouest", "sud" ] | 0.133 | ITR | NULL | | 0 | 65.24 | 65.24 | 65.24 | 0.98 | | | | ITI | dalle béton | 42.19 | 42.19 | 0.37 | NULL | | | | non isole | plafond avec ou sans remplissage sous combles | 42.19 | 42.19 | 2.5 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001265H | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2013-07-14 00:00:00 | NULL | NULL | NULL | 135 | NULL | NULL | NULL | | | E | F | 255 | 62 | individuel | fioul | chaudiere fioul standard | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 6.3 | 11.8 | 1 | 0 | NULL | tout venant | 3.5 | 4.8 | 0.56 | 0 | [ "nord", "ouest", "sud" ] | 0.26 | ITI | NULL | murs en briques pleines doubles avec lame d'air | 30 | 60.05 | 54.35 | 60.05 | 2 | | | | non isole | plancher lourd type entrevous terre-cuite, poutrelles béton | 135 | 135 | 2 | NULL | | | | ITI | dalle béton | 135 | 135 | 0.24 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001266I | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1989-2000 | 2000 | | NULL | 2013-07-14 00:00:00 | NULL | NULL | NULL | 29 | NULL | NULL | NULL | | | E | C | 266 | 12 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | métal sans rupture de pont thermique | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 3.1 | 4.7 | 4.88 | 0 | | NULL | ITI | NULL | murs en béton banché | 30 | 22.87 | 0 | 22.87 | 0.5 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001269L | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1995 | | NULL | 2013-07-15 00:00:00 | NULL | NULL | NULL | 73 | NULL | NULL | NULL | | | D | B | 206.74 | 9.66 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 4.32 | 0.76 | 0 | NULL | non traversant | 2.4 | 2.9 | 0.48 | 1 | [ "indetermine", "ouest", "sud" ] | 0.124 | ITR | NULL | béton cellulaire | 0 | 79.42 | 38.62 | 79.42 | 0.5 | | | | non isole | dalle béton | 72.56 | 72.56 | 0.37 | NULL | | | | ITI | plafond bois sous solives bois | 75.2 | 75.2 | 0.1 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001270D | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1963 | | NULL | 2013-07-15 00:00:00 | NULL | NULL | NULL | 70 | NULL | NULL | NULL | | | D | E | 211.86 | 48.61 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ecs solaire | | gaz | chaudiere gaz condensation | | 1 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 2.28 | 5.21 | 3.76 | 0 | NULL | tout venant | 2.3 | 2.7 | 0.44 | 1 | [ "nord", "ouest", "sud" ] | 0.146 | non isole | NULL | | 0 | 65.84 | 65.84 | 65.84 | 2 | | | | non isole | dalle béton | 70.27 | 70.27 | 2 | NULL | | | | non isole | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001271E | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1989 | | NULL | 2013-07-15 00:00:00 | NULL | NULL | NULL | 85 | NULL | NULL | NULL | | | D | B | 203.05 | 10.13 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | simple vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 3.35 | 3.31 | 0 | 1.3 | NULL | tout venant | 3.4 | NULL | 0.52 | 0 | [ "est", "nord", "sud" ] | 0.11 | ITI | NULL | murs en blocs de béton creux | 20 | 83.53 | 64.33 | 83.53 | 0.5 | | | | ITE | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | plafond bois sous solives bois | 85 | 85 | 0.33 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001272F | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2006-2012 | 2006 | | NULL | 2013-07-15 00:00:00 | NULL | NULL | NULL | 109 | NULL | NULL | NULL | | | C | C | 98 | 16 | individuel | electricite | pac air/air | | gaz | chaudiere gaz condensation | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 6.26 | 11.55 | 3.91 | 0 | NULL | tout venant | 2.6 | 2.6 | 0.44 | 0 | [ "nord", "ouest", "sud" ] | 0.221 | ITI | NULL | murs en blocs de béton creux | 20 | 91.39 | 76.39 | 91.39 | 0.4 | | | | ITE | plancher à entrevous isolant | 109.3 | 109.3 | 0.36 | NULL | | | | ITI | plafond bois sous solives bois | 109.3 | 109.3 | 0.25 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001273G | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-07-15 00:00:00 | NULL | NULL | NULL | 48 | NULL | NULL | NULL | | | D | B | 192 | 8 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 6.73 | 0 | 0 | 0 | NULL | non traversant | 3 | 3 | 0.44 | 0 | [ "nord" ] | 0.308 | ITI | NULL | murs en béton banché | 22.5 | 73.48 | 15.14 | 41.33 | 0.4 | | | | ITE | dalle béton | 47.6 | 47.6 | 0.36 | NULL | | | | ITI | dalle béton | 47.6 | 0 | 0.25 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001274H | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-07-15 00:00:00 | NULL | NULL | NULL | 42 | NULL | NULL | NULL | | | D | B | 171 | 6 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 6.82 | 0 | 0 | 0 | NULL | non traversant | 3 | 3 | 0.44 | 0 | [ "nord" ] | 0.357 | ITI | NULL | murs en béton banché | 22.5 | 63.68 | 12.3 | 12.3 | 0.4 | | | | ITE | dalle béton | 41.5 | 41.5 | 0.36 | NULL | | | | ITI | dalle béton | 41.5 | 0 | 0.25 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001275I | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2013-07-15 00:00:00 | NULL | NULL | NULL | 106 | NULL | NULL | NULL | | | B | A | 77 | 2 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | métal avec rupture de pont thermique | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 1.32 | 5.11 | 13.33 | 0 | NULL | tout venant | 2.7 | 3.5 | 0.52 | 0 | [ "nord", "ouest", "sud" ] | 0.247 | ITI | NULL | murs en béton banché | 20 | 88.34 | 60.24 | 60.24 | 0.35 | | | | non isole | dalle béton | 106 | 0 | 2 | NULL | | | | non isole | dalle béton | 106 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001280E | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-07-15 00:00:00 | NULL | NULL | NULL | 50 | NULL | NULL | NULL | | | D | A | 161.91 | 5.35 | individuel | electricite | pac air/eau | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0 | 0 | 0 | 7.5 | NULL | non traversant | 1.8 | NULL | 0.38 | 0 | [ "est" ] | 0.391 | ITI | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 40 | 18.02 | 11.68 | 18.02 | 2 | | | | ITI | dalle béton | 50 | 50 | 0.27 | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1001281F | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1978-1982 | 1978 | | NULL | 2013-07-15 00:00:00 | NULL | NULL | NULL | 75 | NULL | NULL | NULL | | | E | C | 259 | 15 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | métal sans rupture de pont thermique | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 1.24 | 4.97 | 2.92 | NULL | tout venant | 3.5 | NULL | 0.49 | 0 | [ "est", "ouest", "sud" ] | 0.129 | ITI | NULL | murs en béton banché | 20 | 75.69 | 61.62 | 75.69 | 0.89 | | | | non isole | dalle béton | 75 | 75 | 0.37 | NULL | | | | ITI | plafond bois sous solives métalliques | 75 | 75 | 0.44 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |