| 1313V1000601A | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1978-1982 | 1980 | | NULL | 2013-06-18 00:00:00 | NULL | NULL | NULL | 212 | NULL | NULL | NULL | | | C | A | 132.2 | 5.98 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0.8 | 48.12 | 8.23 | 4.68 | NULL | non traversant | 1.5 | 1.5 | 0.47 | 1 | [ "est", "nord", "ouest", "sud" ] | 0.349 | ITI | NULL | murs en blocs de béton creux | 25 | 280.05 | 115.19 | 280.05 | 0.34 | | | | ITI | dalle béton | 143 | 143 | 0.35 | NULL | | | | ITI | combles aménagés sous rampant | 143.35 | 143.35 | 0.19 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000602B | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1965 | | NULL | 2013-06-18 00:00:00 | NULL | NULL | NULL | 68 | NULL | NULL | NULL | | | D | C | 184.37 | 20.45 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | electricite | pac air/air | | collectif | | ecs solaire | | gaz | chaudiere gaz standard | | 1 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 0 | 11.55 | 2.83 | NULL | non traversant | 3.8 | 4.5 | 0.48 | 1 | [ "est", "ouest" ] | 0.391 | non isole | NULL | murs en béton banché | 30 | 37.44 | 22.37 | 37.44 | 2 | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000603C | 13 | 0 | dpe arrêté 2012 3cl immeuble | immeuble | 1948-1974 | 1950 | | NULL | 2013-06-18 00:00:00 | NULL | NULL | NULL | NULL | NULL | NULL | NULL | | | F | D | 449.9 | 24.74 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 16.2 | 0 | 0 | 15.44 | NULL | 90° | 1.5 | 1.5 | 0.44 | 0 | [ "est", "nord" ] | NULL | non isole | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 50 | 108.9 | 0 | 108.9 | 2 | | | | non isole | dalle béton | 29.2 | 29.2 | 0.37 | NULL | | | | ITI | combles aménagés sous rampant | 29.2 | 29.2 | 0.34 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000604D | 13 | 0 | dpe arrêté 2012 3cl immeuble | immeuble | 1948-1974 | 1950 | | NULL | 2013-06-18 00:00:00 | NULL | NULL | NULL | NULL | NULL | NULL | NULL | | | F | D | 449.9 | 24.74 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 16.2 | 0 | 0 | 15.44 | NULL | 90° | 1.5 | 1.5 | 0.44 | 0 | [ "est", "nord" ] | NULL | non isole | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 50 | 108.9 | 0 | 108.9 | 2 | | | | non isole | dalle béton | 29.2 | 29.2 | 0.37 | NULL | | | | ITI | combles aménagés sous rampant | 29.2 | 29.2 | 0.34 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000605E | 13 | 0 | dpe arrêté 2012 3cl immeuble | immeuble | 1948-1974 | 1950 | | NULL | 2013-06-18 00:00:00 | NULL | NULL | NULL | NULL | NULL | NULL | NULL | | | F | D | 449.9 | 24.74 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 16.2 | 0 | 0 | 15.44 | NULL | 90° | 1.5 | 1.5 | 0.44 | 0 | [ "est", "nord" ] | NULL | non isole | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 50 | 108.9 | 0 | 108.9 | 2 | | | | non isole | dalle béton | 29.2 | 29.2 | 0.37 | NULL | | | | ITI | combles aménagés sous rampant | 29.2 | 29.2 | 0.34 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000606F | 13 | 0 | dpe arrêté 2012 3cl immeuble | immeuble | 1948-1974 | 1950 | | NULL | 2013-06-18 00:00:00 | NULL | NULL | NULL | NULL | NULL | NULL | NULL | | | F | D | 449.9 | 24.74 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 16.2 | 0 | 0 | 15.44 | NULL | 90° | 1.5 | 1.5 | 0.44 | 0 | [ "est", "nord" ] | NULL | non isole | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 50 | 108.9 | 0 | 108.9 | 2 | | | | non isole | dalle béton | 29.2 | 29.2 | 0.37 | NULL | | | | ITI | combles aménagés sous rampant | 29.2 | 29.2 | 0.34 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000615F | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-06-18 00:00:00 | NULL | NULL | NULL | 110 | NULL | NULL | NULL | | | D | B | 173 | 8 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 1.74 | 12.5 | 5.17 | NULL | tout venant | 2.2 | 2.8 | 0.44 | 0 | [ "est", "ouest", "sud" ] | 0.221 | non isole | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 50 | 133.83 | 68.29 | 82.83 | 2 | | | | non isole | voutains en briques ou moellons | 110 | 0 | 0.8 | NULL | | | | non isole | plafond lourd type entrevous terre-cuite, poutrelles béton | 110 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000616G | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2013-06-19 00:00:00 | NULL | NULL | NULL | 67 | NULL | NULL | NULL | | | F | F | 404 | 73 | individuel | gaz | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | simple vitrage | métal sans rupture de pont thermique | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 3.2 | 11.1 | 0 | 0 | NULL | non traversant | 4.4 | NULL | 0.58 | 0 | [ "nord", "sud" ] | 0.21 | non isole | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 30 | 67.9 | 53.7 | 67.9 | 2 | | | | non isole | dalle béton | 66.6 | 66.6 | 2 | NULL | | | | non isole | dalle béton | 66.6 | 66.6 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000617H | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1975-1977 | 1977 | | NULL | 2013-06-19 00:00:00 | NULL | NULL | NULL | 130 | NULL | NULL | NULL | | | D | D | 215.64 | 34.87 | individuel | electricite | pac air/air | | gaz | chaudiere gaz standard | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 13.25 | 0 | 0 | 5.95 | NULL | 90° | 1.5 | 1.5 | 0.47 | 0 | [ "est", "nord" ] | 0.523 | ITI | NULL | murs en blocs de béton creux | 20 | 145.39 | 17.5 | 145.39 | 0.54 | | | | non isole | dalle béton | 80 | 80 | 2 | NULL | | | | ITI | plafond entre solives bois avec ou sans remplissage | 49 | 49 | 0.17 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000618I | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-06-19 00:00:00 | NULL | NULL | NULL | 55 | NULL | NULL | NULL | | | E | C | 292 | 14 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | métal sans rupture de pont thermique | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 0 | 3.6 | 2.7 | NULL | est ouest | 4 | NULL | 0.49 | 0 | [ "est", "ouest" ] | 0.19 | non isole | NULL | murs en blocs de béton creux | 20 | 26.8 | 26.8 | 26.8 | 2 | | | | non isole | dalle béton | 54.67 | 54.67 | 2 | NULL | | | | non isole | dalle béton | 54.67 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000619J | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-06-19 00:00:00 | NULL | NULL | NULL | 96 | NULL | NULL | NULL | | | D | B | 179 | 8 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0 | 13.8 | 8.5 | 3.4 | NULL | tout venant | 2.2 | 2.6 | 0.44 | 1 | [ "est", "ouest", "sud" ] | 0.242 | ITI | NULL | murs en briques creuses | 28 | 80.3 | 80.3 | 80.3 | 0.39 | | | | non isole | dalle béton | 96.47 | 0 | 2 | NULL | | | | non isole | dalle béton | 96.47 | 96.47 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000620B | 13 | 0 | dpe arrêté 2012 facture logement | maison | 1975-1977 | 1975 | | NULL | 2013-06-19 00:00:00 | NULL | NULL | NULL | 100 | NULL | NULL | NULL | | | N | N | 0 | 0 | | bois | poele ou insert bois | | | | | 0 | NULL | NULL | | | | | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | | bois | | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | | NULL | murs en blocs de béton creux | NULL | NULL | NULL | NULL | NULL | | | | | dalle béton | NULL | NULL | NULL | NULL | | | | | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000621C | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2001-2005 | 2002 | | NULL | 2013-06-19 00:00:00 | NULL | NULL | NULL | 105 | NULL | NULL | NULL | | | D | D | 152.39 | 34.58 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | electricite | pac air/air | | collectif | | ecs solaire | | gaz | chaudiere gaz standard | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 3.44 | 7.82 | 1.44 | 0 | NULL | tout venant | 2.2 | 2.6 | 0.44 | 1 | [ "nord", "ouest", "sud" ] | 0.112 | ITI | NULL | murs en blocs de béton creux | 20 | 100.31 | 100.31 | 100.31 | 0.47 | | | | ITE | plancher à entrevous isolant | 110.25 | 110.25 | 0.45 | NULL | | | | ITI | plafond en plaque de plâtre | 110.25 | 110.25 | 0.3 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000622D | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1975-1977 | 1975 | | NULL | 2013-06-19 00:00:00 | NULL | NULL | NULL | 100 | NULL | NULL | NULL | | | E | C | 265 | 13 | individuel | electricite | generateurs a effet joule | | bois | poele ou insert bois | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | bois | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.7 | 2.8 | 1.6 | 0 | | 0.232 | ITI | NULL | murs en blocs de béton creux | NULL | 95.41 | 12.6 | 95.41 | 1.1 | | | | ITI | dalle béton | 99.57 | 99.57 | 0.34 | NULL | | | | ITE | plafond lourd type entrevous terre-cuite, poutrelles béton | 99.57 | 99.57 | 0.34 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000624F | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-06-19 00:00:00 | NULL | NULL | NULL | 56 | NULL | NULL | NULL | | | D | E | 168 | 39 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0 | 0 | 6.14 | 4.75 | NULL | est ouest | 3.5 | 4.7 | 0.52 | 0 | [ "est", "ouest" ] | 0.317 | non isole | NULL | murs en pan de bois sans remplissage tout venant | 8 | 34.5 | 23.44 | 34.5 | 1.2 | | | | non isole | dalle béton | 55.87 | 0 | 2 | NULL | | | | non isole | dalle béton | 55.87 | 0 | 2.5 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000625 | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1992 | | NULL | 2013-06-19 00:00:00 | NULL | NULL | NULL | 110 | NULL | NULL | NULL | | | C | B | 132.37 | 9.23 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 9.63 | 14.01 | 4.5 | 2.61 | NULL | tout venant | 1.5 | 1.5 | 0.4 | 0 | [ "est", "nord", "ouest", "sud" ] | NULL | ITI | NULL | murs en briques creuses | 25 | 91.55 | 0 | 91.55 | 0.5 | | | | ITE | plancher à entrevous isolant | 110 | 110 | 0.61 | NULL | | | | ITI | plafond en plaque de plâtre | 110 | 110 | 0.25 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000626H | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1992 | | NULL | 2013-06-19 00:00:00 | NULL | NULL | NULL | 110 | NULL | NULL | NULL | | | C | B | 132.37 | 9.23 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 9.63 | 14.01 | 4.5 | 2.61 | NULL | tout venant | 1.5 | 1.5 | 0.4 | 0 | [ "est", "nord", "ouest", "sud" ] | NULL | ITI | NULL | murs en briques creuses | 25 | 91.55 | 0 | 91.55 | 0.5 | | | | ITE | plancher à entrevous isolant | 110 | 110 | 0.61 | NULL | | | | ITI | plafond en plaque de plâtre | 110 | 110 | 0.25 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000629K | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-06-19 00:00:00 | NULL | NULL | NULL | 87 | NULL | NULL | NULL | | | E | C | 248.61 | 13.38 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | simple vitrage | bois | | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 8 | 0 | 0 | 23.12 | NULL | 90° | 1.5 | 1.5 | 0.52 | 0 | [ "est", "nord" ] | NULL | non isole | NULL | murs en pierre de taille et moellons avec remplissage tout venant | 65 | 79.76 | 0 | 58.34 | 1.5 | | | | non isole | | 83.28 | 83.28 | 2 | NULL | | | | non isole | plafond entre solives bois avec ou sans remplissage | 83.28 | 83.28 | 1.2 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000631D | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2013-06-19 00:00:00 | NULL | NULL | NULL | 121 | NULL | NULL | NULL | | | D | E | 222 | 43 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | ecs thermodynamique electrique(pac ou ballon) | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | métal avec rupture de pont thermique | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 15 | 13 | 0 | 10 | NULL | tout venant | 2.7 | 3.3 | 0.52 | 0 | [ "est", "nord", "sud" ] | 0.325 | ITI+ITR | NULL | murs en briques pleines doubles avec lame d'air | 20 | 79 | 79 | 79 | 0.98 | | | | non isole | dalle béton | 121 | 121 | 2 | NULL | | | | non isole | dalle béton | 121 | 121 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000634G | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-06-19 00:00:00 | NULL | NULL | NULL | 47 | NULL | NULL | NULL | | | C | A | 142 | 3 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0 | 9 | 0 | 0 | NULL | non traversant | 2.6 | 3.1 | 0.48 | 0 | [ "sud" ] | 0.474 | ITI+ITR | NULL | murs en béton banché | 30 | 10 | 10 | 10 | 0.98 | | | | non isole | | 46.85 | 0 | 2 | NULL | | | | non isole | dalle béton | 46.85 | 0 | 2.5 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000637J | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1975-1977 | 1977 | | NULL | 2013-06-19 00:00:00 | NULL | NULL | NULL | 41 | NULL | NULL | NULL | | | E | C | 258 | 13 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | | pvc | | | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | NULL | NULL | NULL | 0 | | NULL | non isole | NULL | murs en blocs de béton creux | NULL | 19.75 | 0 | 19.75 | NULL | | | | | plancher lourd type entrevous terre-cuite, poutrelles béton | 41 | 41 | 0.59 | NULL | | | | | plafond lourd type entrevous terre-cuite, poutrelles béton | 41 | 41 | 0.61 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000638 | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1989-2000 | 2000 | | NULL | 2013-06-19 00:00:00 | NULL | NULL | NULL | 96 | NULL | NULL | NULL | | | C | B | 147 | 7 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.9 | 2.8 | 2.71 | 0 | | NULL | non isole | NULL | murs en béton banché | 20 | 55.68 | 0 | 55.68 | 0.43 | | | | ITI | dalle béton | 95.78 | 95.78 | 0.22 | NULL | | | | ITI | dalle béton | 95.78 | 95.78 | 0.22 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000639L | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1955 | | NULL | 2013-06-19 00:00:00 | NULL | NULL | NULL | 78 | NULL | NULL | NULL | | | E | C | 244.93 | 12.18 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | métal sans rupture de pont thermique | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0 | 1.47 | 7.8 | 5.85 | NULL | tout venant | 2.3 | 2.6 | 0.54 | 0 | [ "est", "ouest", "sud" ] | 0.162 | non isole | NULL | murs en blocs de béton pleins | 38 | 78.34 | 78.34 | 78.34 | 2 | | | | non isole | dalle béton | 78.11 | 78.11 | 0.35 | NULL | | | | ITI | combles aménagés sous rampant | 78.11 | 78.11 | 0.19 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000640D | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1989-2000 | 2000 | | NULL | 2013-06-19 00:00:00 | NULL | NULL | NULL | 96 | NULL | NULL | NULL | | | C | B | 139 | 6 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.9 | 2.8 | 2.71 | 0 | | NULL | non isole | NULL | murs en béton banché | 20 | 55.68 | 0 | 55.68 | 0.43 | | | | ITI | dalle béton | 95.78 | 95.78 | 0.22 | NULL | | | | ITI | dalle béton | 95.78 | 95.78 | 0.22 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000641E | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2001-2005 | 2001 | | NULL | 2013-06-19 00:00:00 | NULL | NULL | NULL | 170 | NULL | NULL | NULL | | | C | A | 100 | 5 | individuel | electricite | pac air/eau | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Extracteur mécanique sur conduit non modifié de ventilation naturelle existante | | double vitrage | pvc | | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0.5 | 12.35 | 3.2 | 0.5 | NULL | tout venant | 2.3 | 2.6 | 0.44 | 0 | [ "est", "nord", "ouest", "sud" ] | 0.068 | ITI | NULL | murs en blocs de béton creux | 20 | 226.45 | 226.45 | 226.45 | 0.47 | | | | ITE | plancher à entrevous isolant | 120 | 120 | 0.43 | NULL | | | | ITI | plafond bois sous solives bois | 120 | 120 | 0.3 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000644H | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2013-06-19 00:00:00 | NULL | NULL | NULL | 84 | NULL | NULL | NULL | | | C | A | 118 | 5 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 6.61 | 0 | 2.27 | 4.77 | NULL | tout venant | 2.2 | 2.6 | 0.46 | 0 | [ "est", "nord", "ouest" ] | 0.245 | ITI | NULL | murs en béton banché | 20 | 57.96 | 42.14 | 57.96 | 0.4 | | | | non isole | dalle béton | 83.73 | 0 | 2 | NULL | | | | non isole | dalle béton | 83.73 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000645 | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2013-06-19 00:00:00 | NULL | NULL | NULL | 121 | NULL | NULL | NULL | | | D | E | 222 | 43 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | ecs thermodynamique electrique(pac ou ballon) | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | métal avec rupture de pont thermique | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 15 | 13 | 0 | 10 | NULL | tout venant | 2.7 | 3.3 | 0.52 | 0 | [ "est", "nord", "sud" ] | 0.325 | ITI+ITR | NULL | murs en briques pleines doubles avec lame d'air | 20 | 79 | 79 | 79 | 0.98 | | | | non isole | dalle béton | 121 | 121 | 2 | NULL | | | | non isole | dalle béton | 121 | 121 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000646J | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1978-1982 | 1978 | | NULL | 2013-06-19 00:00:00 | NULL | NULL | NULL | 120 | NULL | NULL | NULL | | | E | C | 284 | 15 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0.44 | 10.57 | 0 | 1.88 | NULL | tout venant | 3.4 | 4.7 | 0.52 | 0 | [ "est", "est ou ouest", "nord", "sud" ] | 0.135 | ITI | NULL | murs en blocs de béton creux | 20 | 102.32 | 94.95 | 102.32 | 0.89 | | | | ITE | plancher lourd type entrevous terre-cuite, poutrelles béton | 120 | 120 | 0.89 | NULL | | | | ITE | plafond lourd type entrevous terre-cuite, poutrelles béton | 120 | 120 | 0.2 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000647 | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2013-06-19 00:00:00 | NULL | NULL | NULL | 121 | NULL | NULL | NULL | | | D | E | 222 | 43 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | ecs thermodynamique electrique(pac ou ballon) | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | métal avec rupture de pont thermique | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 15 | 13 | 0 | 10 | NULL | tout venant | 2.7 | 3.3 | 0.52 | 0 | [ "est", "nord", "sud" ] | 0.325 | ITI+ITR | NULL | murs en briques pleines doubles avec lame d'air | 20 | 79 | 79 | 79 | 0.98 | | | | non isole | dalle béton | 121 | 121 | 2 | NULL | | | | non isole | dalle béton | 121 | 121 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000648 | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2013-06-19 00:00:00 | NULL | NULL | NULL | 121 | NULL | NULL | NULL | | | D | E | 222 | 43 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | ecs thermodynamique electrique(pac ou ballon) | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | métal avec rupture de pont thermique | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 15 | 13 | 0 | 10 | NULL | tout venant | 2.7 | 3.3 | 0.52 | 0 | [ "est", "nord", "sud" ] | 0.325 | ITI+ITR | NULL | murs en briques pleines doubles avec lame d'air | 20 | 79 | 79 | 79 | 0.98 | | | | non isole | dalle béton | 121 | 121 | 2 | NULL | | | | non isole | dalle béton | 121 | 121 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000649 | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2013-06-19 00:00:00 | NULL | NULL | NULL | 121 | NULL | NULL | NULL | | | D | E | 222 | 43 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | ecs thermodynamique electrique(pac ou ballon) | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | métal avec rupture de pont thermique | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 15 | 13 | 0 | 10 | NULL | tout venant | 2.7 | 3.3 | 0.52 | 0 | [ "est", "nord", "sud" ] | 0.325 | ITI+ITR | NULL | murs en briques pleines doubles avec lame d'air | 20 | 79 | 79 | 79 | 0.98 | | | | non isole | dalle béton | 121 | 121 | 2 | NULL | | | | non isole | dalle béton | 121 | 121 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000650 | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2013-06-19 00:00:00 | NULL | NULL | NULL | 121 | NULL | NULL | NULL | | | D | E | 222 | 43 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | ecs thermodynamique electrique(pac ou ballon) | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | métal avec rupture de pont thermique | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 15 | 13 | 0 | 10 | NULL | tout venant | 2.7 | 3.3 | 0.52 | 0 | [ "est", "nord", "sud" ] | 0.325 | ITI+ITR | NULL | murs en briques pleines doubles avec lame d'air | 20 | 79 | 79 | 79 | 0.98 | | | | non isole | dalle béton | 121 | 121 | 2 | NULL | | | | non isole | dalle béton | 121 | 121 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000651F | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2013-06-19 00:00:00 | NULL | NULL | NULL | 121 | NULL | NULL | NULL | | | D | E | 222 | 43 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | ecs thermodynamique electrique(pac ou ballon) | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | métal avec rupture de pont thermique | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 15 | 13 | 0 | 10 | NULL | tout venant | 2.7 | 3.3 | 0.52 | 0 | [ "est", "nord", "sud" ] | 0.325 | ITI+ITR | NULL | murs en briques pleines doubles avec lame d'air | 20 | 79 | 79 | 79 | 0.98 | | | | non isole | dalle béton | 121 | 121 | 2 | NULL | | | | non isole | dalle béton | 121 | 121 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000652G | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2013-06-19 00:00:00 | NULL | NULL | NULL | 121 | NULL | NULL | NULL | | | D | E | 222 | 43 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | ecs thermodynamique electrique(pac ou ballon) | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | métal avec rupture de pont thermique | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 15 | 13 | 0 | 10 | NULL | tout venant | 2.7 | 3.3 | 0.52 | 0 | [ "est", "nord", "sud" ] | 0.325 | ITI+ITR | NULL | murs en briques pleines doubles avec lame d'air | 20 | 79 | 79 | 79 | 0.98 | | | | non isole | dalle béton | 121 | 121 | 2 | NULL | | | | non isole | dalle béton | 121 | 121 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000653H | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1978-1982 | 1981 | | NULL | 2013-06-19 00:00:00 | NULL | NULL | NULL | 150 | NULL | NULL | NULL | | | C | D | 130.73 | 30.59 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | electricite | ecs thermodynamique electrique(pac ou ballon) | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | simple vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 3.1 | 3.57 | 5.06 | 9.98 | NULL | tout venant | 3.5 | 4.7 | 1.62 | 0 | [ "est", "nord", "ouest", "sud" ] | 0.177 | non isole | NULL | | 0 | 100.71 | 100.71 | 100.71 | 2 | | | | non isole | dalle béton | 75 | 75 | 0.31 | NULL | | | | ITI | dalle béton | 150 | 75 | 0.44 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000654I | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1983-1988 | 1983 | | NULL | 2013-06-19 00:00:00 | NULL | NULL | NULL | 85 | NULL | NULL | NULL | | | D | A | 228 | 3 | individuel | bois | poele ou insert bois | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Extracteur mécanique sur conduit non modifié de ventilation naturelle existante | | double vitrage | pvc | | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0 | 1.5 | 6.1 | 2.82 | NULL | tout venant | 2.7 | 2.6 | 0.44 | 0 | [ "est", "ouest", "sud" ] | 0.102 | ITI | NULL | murs en blocs de béton creux | 25 | 91.94 | 91.94 | 91.94 | 0.52 | | | | non isole | dalle béton | 52 | 52 | 0.35 | NULL | | | | ITI | plafond bois sous solives bois | 38 | 38 | 0.24 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000655J | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2013-06-19 00:00:00 | NULL | NULL | NULL | 90 | NULL | NULL | NULL | | | D | E | 200 | 50 | individuel | fioul | chaudiere fioul standard | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 2.68 | 4.02 | 0 | 2.28 | NULL | tout venant | 2.4 | 2.9 | 0.47 | 0 | [ "est", "nord", "sud" ] | 0.088 | non isole | NULL | murs en briques pleines doubles avec lame d'air | 30 | 93.32 | 93.32 | 93.32 | 1.65 | | | | non isole | dalle béton | 90 | 90 | 0.37 | NULL | | | | ITI | dalle béton | 90 | 90 | 0.34 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000656K | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2013-06-19 00:00:00 | NULL | NULL | NULL | 60 | NULL | NULL | NULL | | | D | B | 196 | 8 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | argon ou krypton | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 7.06 | 4.71 | 0 | 0 | NULL | nord sud | 2.3 | 2.6 | 0.44 | 0 | [ "nord", "sud" ] | 0.207 | ITI | NULL | murs en briques creuses | 33 | 65.15 | 45.06 | 45.06 | 0.38 | | | | ITI | dalle béton | 60.24 | 60.24 | 0.37 | NULL | | | | ITI | plafond avec ou sans remplissage sous combles | 60.24 | 60.24 | 0.34 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000657L | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1983-1988 | 1983 | | NULL | 2013-06-19 00:00:00 | NULL | NULL | NULL | 100 | NULL | NULL | NULL | | | D | C | 223 | 12 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 3.94 | 0 | 4.96 | 6 | NULL | tout venant | 2.2 | 2.6 | 0.44 | 0 | [ "est", "nord", "ouest" ] | 0.2 | ITI | NULL | murs en blocs de béton creux | 20 | 128.19 | 59.73 | 72.51 | 0.42 | | | | ITE | dalle béton | 64.9 | 64.9 | 0.61 | NULL | | | | ITI | plafond bois sous solives bois | 43 | 43 | 0.15 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000659N | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2013-06-19 00:00:00 | NULL | NULL | NULL | 44 | NULL | NULL | NULL | | | D | B | 202 | 8 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | argon ou krypton | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 1.9 | 2.2 | 2.47 | 0 | | NULL | ITI | NULL | murs en béton banché | NULL | 15.53 | 0 | 15.53 | NULL | | | | ITI | dalle béton | 43.88 | 43.88 | 0.19 | NULL | | | | ITI | dalle béton | 43.88 | 43.88 | 0.19 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000660F | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 2000 | | NULL | 2013-06-20 00:00:00 | NULL | NULL | NULL | 54 | NULL | NULL | NULL | | | E | C | 328 | 17 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.9 | 2.8 | 1.31 | 1 | | 0.072 | ITI | NULL | murs en blocs de béton creux | 20 | 83.55 | 46.96 | 83.55 | 0.35 | | | | ITE | dalle béton | 54 | 54 | 0.35 | NULL | | | | | combles aménagés sous rampant | 60 | 60 | 0.3 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000661G | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2006-2012 | 2006 | | NULL | 2013-06-20 00:00:00 | NULL | NULL | NULL | 190 | NULL | NULL | NULL | | | C | A | 105 | 4 | individuel | electricite | generateurs a effet joule | | bois | poele ou insert bois | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | argon ou krypton | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 1.9 | 2.2 | 2.7 | 0 | | 0.069 | ITI | NULL | murs en blocs de béton creux | 20 | 177.55 | 118.79 | 177.55 | 0.35 | | | | ITE | plancher à entrevous isolant | 106.3 | 106.3 | 0.36 | NULL | | | | | plafond en plaque de plâtre | 85 | 85 | 0.15 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000662H | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1975-1977 | 1975 | | NULL | 2013-06-20 00:00:00 | NULL | NULL | NULL | 100 | NULL | NULL | NULL | | | E | C | 266 | 13 | individuel | electricite | generateurs a effet joule | | bois | poele ou insert bois | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | bois | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.7 | 2.8 | 1.6 | 0 | | 0.232 | ITI | NULL | murs en blocs de béton creux | NULL | 95.41 | 12.6 | 95.41 | 1.1 | | | | ITI | dalle béton | 99.57 | 99.57 | 0.34 | NULL | | | | ITE | plafond lourd type entrevous terre-cuite, poutrelles béton | 99.57 | 99.57 | 0.34 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000664J | 13 | 0 | dpe arrêté 2012 facture logement | appartement | 1948-1974 | 1960 | | NULL | 2013-06-20 00:00:00 | NULL | NULL | NULL | 38 | NULL | NULL | NULL | | | N | N | 0 | 0 | | | | | | | | 0 | NULL | NULL | | | | individuel | | chauffe-eau gaz independant | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | non traversant | NULL | NULL | NULL | 0 | [ "sud" ] | NULL | ITI | NULL | murs en blocs de béton pleins | NULL | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000665K | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-06-20 00:00:00 | NULL | NULL | NULL | 67 | NULL | NULL | NULL | | | F | D | 337 | 28 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 3.72 | 8.8 | 0 | 0 | NULL | nord sud | 2.2 | 2.6 | 0.44 | 0 | [ "nord", "sud" ] | 0.303 | non isole | NULL | murs en béton banché | 25 | 46.07 | 28.83 | 46.07 | 2 | | | | non isole | dalle béton | 67 | 0 | 2 | NULL | | | | non isole | dalle béton | 67 | 67 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000667M | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1978-1982 | 1978 | | NULL | 2013-06-20 00:00:00 | NULL | NULL | NULL | 96 | NULL | NULL | NULL | | | C | C | 101 | 20 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 1.4 | 5.1 | 0 | 6.2 | NULL | tout venant | 2.2 | 2.6 | 0.44 | 1 | [ "est", "nord", "sud" ] | 0.125 | ITI | NULL | murs en blocs de béton creux | 20 | 89.3 | 89.3 | 89.3 | 0.42 | | | | non isole | dalle béton | 48.61 | 0 | 2 | NULL | | | | ITI | plafond bois sous solives bois | 47.26 | 47.26 | 0.18 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000668N | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-06-20 00:00:00 | NULL | NULL | NULL | 58 | NULL | NULL | NULL | | | C | D | 130 | 30 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | simple vitrage | bois | | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 5 | 5 | 0 | 0 | NULL | nord sud | 4 | 4.7 | 0.52 | 0 | [ "nord", "sud" ] | 0.238 | non isole | NULL | murs en béton banché | 30 | 41.4 | 32 | 41.4 | 2 | | | | non isole | plancher lourd type entrevous terre-cuite, poutrelles béton | 57.86 | 0 | 2 | NULL | | | | non isole | plafond lourd type entrevous terre-cuite, poutrelles béton | 57.86 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000670G | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1975-1977 | 1975 | | NULL | 2013-06-20 00:00:00 | NULL | NULL | NULL | 77 | NULL | NULL | NULL | | | D | E | 185 | 43 | individuel | gaz | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | métal sans rupture de pont thermique | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 7.62 | 5.24 | 0 | 0 | NULL | nord sud | 3.4 | NULL | 0.54 | 1 | [ "nord", "sud" ] | 0.165 | ITE | NULL | murs en béton banché | 20 | 121 | 65.25 | 78.5 | 0.98 | | | | non isole | | 50 | 50 | 0.37 | NULL | | | | ITI | plafond entre solives bois avec ou sans remplissage | 67 | 67 | 0.56 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000671H | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1983-1988 | 1985 | | NULL | 2013-06-20 00:00:00 | NULL | NULL | NULL | 126 | NULL | NULL | NULL | | | D | B | 176.75 | 8.97 | individuel | electricite | pac air/air | | electricite | chaudiere electrique | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | simple vitrage | bois | argon ou krypton | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 1.1 | 7.41 | 5.86 | 1.44 | NULL | tout venant | 3.6 | 4.7 | 0.48 | 1 | [ "est", "nord", "ouest", "sud" ] | 0.131 | ITI | NULL | murs en blocs de béton creux | 20 | 127.14 | 105.2 | 127.14 | 0.54 | | | | non isole | plancher avec ou sans remplissage | 126 | 126 | 1.45 | NULL | | | | ITI | dalle béton | 125.96 | 125.96 | 0.47 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000672I | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1975-1977 | 1975 | | NULL | 2013-06-20 00:00:00 | NULL | NULL | NULL | 77 | NULL | NULL | NULL | | | D | E | 185 | 43 | individuel | gaz | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | métal sans rupture de pont thermique | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 7.62 | 5.24 | 0 | 0 | NULL | nord sud | 3.4 | NULL | 0.54 | 1 | [ "nord", "sud" ] | 0.165 | ITE | NULL | murs en béton banché | 20 | 121 | 65.25 | 78.5 | 0.98 | | | | non isole | | 50 | 50 | 0.37 | NULL | | | | ITI | plafond entre solives bois avec ou sans remplissage | 67 | 67 | 0.56 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |