| 1313L1000118C | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2001-2005 | 2001 | | NULL | 2013-05-30 00:00:00 | NULL | NULL | NULL | 91 | NULL | NULL | NULL | | | B | C | 84 | 19 | individuel | gaz | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0.5 | 6.5 | 6 | 0 | NULL | tout venant | 2.2 | 2.6 | 0.46 | 0 | [ "nord", "ouest", "sud" ] | 0.12 | ITI | NULL | murs en béton banché | 20 | 133 | 95 | 95 | 0.43 | | | | ITE | dalle béton | 45.43 | 45.43 | 0.43 | NULL | | | | ITI | plafond bois sous solives bois | 45.43 | 45.43 | 0.24 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000120V | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-05-30 00:00:00 | NULL | NULL | NULL | 42 | NULL | NULL | NULL | | | G | D | 550 | 33 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 1.44 | 2.55 | 0 | 0 | NULL | nord sud | 2.4 | 3 | 0.44 | 0 | [ "nord", "sud" ] | 0.114 | ITI | NULL | | 0 | 79.63 | 31.15 | 31.15 | 0.84 | | | | non isole | | 42.45 | 0 | 2 | NULL | | | | | plafond entre solives bois avec ou sans remplissage | 42.45 | 42.45 | 1.2 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000121W | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-05-30 00:00:00 | NULL | NULL | NULL | 33 | NULL | NULL | NULL | | | D | C | 214 | 11 | individuel | electricite | chaudiere electrique | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | individuel | | chaudiere electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0.17 | 0 | 3.21 | 0 | NULL | non traversant | 2.4 | 3 | 0.44 | 0 | [ "nord", "ouest" ] | 0.282 | ITR | NULL | murs en béton banché | 30 | 8.61 | 8.61 | 8.61 | 0.98 | | | | non isole | dalle béton | 33.37 | 0 | 2 | NULL | | | | non isole | dalle béton | 33.37 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000126B | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-05-30 00:00:00 | NULL | NULL | NULL | 23 | NULL | NULL | NULL | | | F | D | 422 | 21 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 4 | 0 | NULL | non traversant | 3.4 | 4.7 | 0.52 | 0 | [ "ouest" ] | 0.212 | non isole | NULL | murs en pierre de taille et moellons avec remplissage tout venant | 50 | 53.89 | 14.85 | 23.82 | 1.9 | | | | non isole | plancher entre solives bois avec ou sans remplissage | 23 | 0 | 1.1 | NULL | | | | non isole | plafond entre solives bois avec ou sans remplissage | 23 | 0 | 1.2 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000127C | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2001-2005 | 2001 | | NULL | 2013-05-31 00:00:00 | NULL | NULL | NULL | 52 | NULL | NULL | NULL | | | D | B | 176 | 6 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 0 | 0 | 6.3 | NULL | non traversant | 2.2 | 2.6 | 0.52 | 1 | [ "est" ] | 0.147 | ITI | NULL | murs en béton banché | 25 | 72.08 | 36.55 | 37.78 | 0.4 | | | | | dalle béton | 52.16 | 0 | 0.43 | NULL | | | | non isole | dalle béton | 52.16 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000128D | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1954 | | NULL | 2013-05-31 00:00:00 | NULL | NULL | NULL | 52 | NULL | NULL | NULL | | | D | B | 196.88 | 8.36 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | métal sans rupture de pont thermique | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 4.48 | 0 | 0 | 0 | NULL | non traversant | 3.4 | 4.5 | 0.52 | 0 | [ "nord" ] | 0.176 | ITI | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 40 | 21 | 21 | 21 | 0.5 | | | | | | NULL | NULL | NULL | NULL | | | | ITI | combles aménagés sous rampant | 45.2 | 45.2 | 0.3 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000129E | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1978-1982 | 1980 | | NULL | 2013-05-31 00:00:00 | NULL | NULL | NULL | 43 | NULL | NULL | NULL | | | D | B | 225.6 | 9.84 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « avant 1982 » | | double vitrage | métal sans rupture de pont thermique | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 5.17 | 0 | 0 | 8.16 | NULL | 90° | 3.4 | 4.3 | 0.57 | 0 | [ "est", "nord" ] | 0.385 | ITI | NULL | murs en béton banché | 20 | 25.18 | 21.29 | 25.18 | 0.63 | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000130W | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1978-1982 | 1980 | | NULL | 2013-05-31 00:00:00 | NULL | NULL | NULL | 67 | NULL | NULL | NULL | | | D | E | 201.29 | 47.1 | individuel | gaz | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | gaz | chaudiere gaz basse temperature | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 2.01 | 0 | 6.02 | 1.17 | NULL | tout venant | 2.5 | NULL | 0.4 | 0 | [ "est", "nord", "ouest" ] | 0.143 | ITI | NULL | murs en béton banché | 20 | 59.47 | 55.33 | 59.47 | 0.63 | | | | ITI | | NULL | NULL | NULL | NULL | | | | non isole | dalle béton | 67.25 | 67.25 | 2.5 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000131X | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-05-31 00:00:00 | NULL | NULL | NULL | 56 | NULL | NULL | NULL | | | D | C | 167 | 15 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0 | 5.34 | 3.06 | 0 | NULL | est ouest | 2.5 | 2.9 | 0.44 | 0 | [ "ouest", "sud" ] | 0.341 | ITR | NULL | murs en béton banché | 30 | 16.23 | 16.23 | 16.23 | 0.4 | | | | non isole | dalle béton | 55.76 | 0 | 2 | NULL | | | | non isole | dalle béton | 55.76 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000134A | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-06-01 00:00:00 | NULL | NULL | NULL | 49 | NULL | NULL | NULL | | | E | C | 294 | 15 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 7.5 | 0 | NULL | non traversant | 2.4 | 3 | 0.44 | 0 | [ "ouest" ] | 0.125 | ITI | NULL | | 0 | 83 | 52.5 | 58 | 0.33 | | | | non isole | | 49.11 | 0 | 2 | NULL | | | | | | 49.11 | 0 | 0.34 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000138E | 13 | 0 | dpe arrêté 2012 facture logement | appartement | avant 1948 | 1900 | | NULL | 2013-06-03 00:00:00 | NULL | NULL | NULL | 37 | NULL | NULL | NULL | | | N | N | 0 | 0 | | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | | NULL | | NULL | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000141Y | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1989 | | NULL | 2013-06-04 00:00:00 | NULL | NULL | NULL | 61 | NULL | NULL | NULL | | | D | B | 187.55 | 7.5 | individuel | electricite | pac air/air | | electricite | chaudiere electrique | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 2.52 | 4.16 | 0 | 1.2 | NULL | tout venant | 1.8 | 2.2 | 0.4 | 0 | [ "est", "nord", "sud" ] | 0.082 | ITI | NULL | murs en blocs de béton creux | 20 | 88.69 | 88.69 | 88.69 | 0.35 | | | | ITE | dalle béton | 60.8 | 60.8 | 0.35 | NULL | | | | ITI | combles aménagés sous rampant | 68.8 | 68.8 | 0.25 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000142@ | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1978-1982 | 1982 | | NULL | 2013-06-04 00:00:00 | NULL | NULL | NULL | 87 | NULL | NULL | NULL | | | D | D | 217.51 | 34.16 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation hybride avec entrées d’air hygroréglables | | double vitrage | pvc | argon ou krypton | | NULL | 0 | 3.14 | 5.22 | 0 | 1 | NULL | tout venant | 2.5 | 2.5 | NULL | 0 | [ "est", "nord", "sud" ] | 0.103 | ITI | NULL | murs en blocs de béton creux | 20 | 81.8 | 81.8 | 63 | 0.42 | | | | isole | dalle béton | 183.76 | 183.76 | 0.22 | NULL | | | | isole | dalle béton | 91.88 | 91.88 | 0.61 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000144B | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2001-2005 | 2004 | | NULL | 2013-06-04 00:00:00 | NULL | NULL | NULL | 65 | NULL | NULL | NULL | | | C | A | 146.42 | 5.53 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 0 | 1.6 | 8.43 | NULL | non traversant | 2.4 | 2.9 | 0.51 | 0 | [ "est", "ouest" ] | 0.232 | ITI | NULL | murs en béton banché | 20 | 33.72 | 33.11 | 33.72 | 0.43 | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000147E | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1975-1977 | 1975 | | NULL | 2013-06-04 00:00:00 | NULL | NULL | NULL | 88 | NULL | NULL | NULL | | | E | F | 248 | 58 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | simple vitrage | bois | | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 2 | 2 | 0 | 0 | NULL | nord sud | 3.7 | 4.7 | 0.52 | 0 | [ "nord", "sud" ] | 0.8 | ITI+ITR | NULL | murs en béton banché | 30 | 1 | 1 | 1 | 0.98 | | | | non isole | dalle béton | 87.86 | 87.86 | 2 | NULL | | | | non isole | dalle béton | 87.86 | 87.86 | 2.5 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000150Y | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1974 | | NULL | 2013-06-04 00:00:00 | NULL | NULL | NULL | 75 | NULL | NULL | NULL | | | D | C | 217 | 11 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | simple vitrage | bois | | | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 5.8 | 4.7 | 4.23 | 0 | | NULL | non isole | NULL | monomur terre cuite | NULL | 86.25 | 0 | 86.25 | NULL | | | | ITE | plancher à entrevous isolant | 75 | 75 | 0.17 | NULL | | | | non isole | dalle béton | 75 | 75 | 2.5 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000152A | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1975-1977 | 1977 | | NULL | 2013-06-04 00:00:00 | NULL | NULL | NULL | 80 | NULL | NULL | NULL | | | D | D | 196.5 | 30.76 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | air sec | | NULL | 0 | 8 | 7.72 | 0 | 0 | NULL | nord sud | 2.6 | 2.6 | NULL | 0 | [ "nord", "sud" ] | 0.203 | ITI | NULL | murs en blocs de béton creux | 20 | 75.82 | 61.54 | 75.82 | 0.74 | | | | non isole | dalle béton | 40 | 40 | 0.37 | NULL | | | | ITI | plafond en plaque de plâtre | 40 | 40 | 0.42 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000155D | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1989-2000 | 1989 | | NULL | 2013-06-05 00:00:00 | NULL | NULL | NULL | 50 | NULL | NULL | NULL | | | D | E | 176 | 41 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | métal sans rupture de pont thermique | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 1.08 | 10.41 | 0 | 0 | NULL | non traversant | 3 | NULL | 0.57 | 0 | [ "nord", "sud" ] | 0.182 | ITI | NULL | murs en blocs de béton creux | 20 | 51.61 | 51.61 | 51.61 | 0.5 | | | | ITE | dalle béton | 50 | 50 | 0.67 | NULL | | | | ITI | plafond avec ou sans remplissage | 50 | 50 | 0.3 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000156E | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2001-2005 | 2001 | | NULL | 2013-06-05 00:00:00 | NULL | NULL | NULL | 19 | NULL | NULL | NULL | | | E | C | 302 | 12 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 4 | 0 | 0 | 0 | NULL | non traversant | 2.2 | 2.7 | 0.38 | 0 | [ "nord" ] | 0.533 | ITI | NULL | murs en béton banché | 20 | 9 | 3.5 | 9 | 0.47 | | | | ITI | dalle béton | 19 | 0 | 0.43 | NULL | | | | non isole | dalle béton | 19 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000157F | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1974 | | NULL | 2013-06-05 00:00:00 | NULL | NULL | NULL | 66 | NULL | NULL | NULL | | | F | F | 378 | 67 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | | bois | | | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | NULL | NULL | NULL | 1 | | NULL | non isole | NULL | murs en blocs de béton pleins | 30 | 35.5 | 0 | 35.5 | 2 | | | | non isole | dalle béton | 65.69 | 65.69 | 2 | NULL | | | | non isole | dalle béton | 65.69 | 65.69 | 2.5 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000158G | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1989-2000 | 1999 | | NULL | 2013-06-05 00:00:00 | NULL | NULL | NULL | 33 | NULL | NULL | NULL | | | F | C | 374.27 | 19.57 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | non traversant | NULL | NULL | NULL | 0 | [ "nord" ] | NULL | non isole | NULL | murs en béton banché | 20 | 36.96 | 19.02 | 36.96 | 0.5 | | | | ITE | dalle béton | 31.05 | 31.05 | 0.61 | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000159H | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1989-2000 | 1989 | | NULL | 2013-06-05 00:00:00 | NULL | NULL | NULL | 69 | NULL | NULL | NULL | | | B | C | 77 | 18 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | métal sans rupture de pont thermique | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 2.97 | 7.26 | 0 | 0 | NULL | nord sud | 3 | NULL | 0.57 | 1 | [ "nord", "sud" ] | 0.353 | ITI | NULL | murs en béton banché | 20 | 28.23 | 18.77 | 28.23 | 0.47 | | | | non isole | dalle béton | 68.87 | 0 | 2 | NULL | | | | non isole | dalle béton | 68.87 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000160@ | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1974 | | NULL | 2013-06-05 00:00:00 | NULL | NULL | NULL | 66 | NULL | NULL | NULL | | | F | F | 371 | 65 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | | bois | | | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | NULL | NULL | NULL | 0 | | 0 | non isole | NULL | murs en blocs de béton pleins | 30 | 41.99 | 2.5 | 41.99 | 0.31 | | | | non isole | dalle béton | 65.69 | 65.69 | 2 | NULL | | | | non isole | dalle béton | 65.69 | 65.69 | 2.5 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000161A | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1989-2000 | 1994 | | NULL | 2013-06-05 00:00:00 | NULL | NULL | NULL | 59 | NULL | NULL | NULL | | | D | B | 206.82 | 9.34 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 0 | 8.16 | 5.76 | NULL | est ouest | 2.4 | NULL | 0.44 | 1 | [ "est", "ouest" ] | 0.328 | ITI | NULL | murs en béton banché | 25 | 36.58 | 28.58 | 36.58 | 0.5 | | | | ITI | | NULL | NULL | NULL | NULL | | | | | dalle béton | 60 | 60 | 0.39 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000162B | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2001-2005 | 2002 | | NULL | 2013-06-05 00:00:00 | NULL | NULL | NULL | 68 | NULL | NULL | NULL | | | D | B | 181.25 | 7.7 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | non traversant | NULL | NULL | NULL | 0 | [ "sud" ] | NULL | ITI+ITE | NULL | murs en béton banché | 30 | 56.18 | 26.93 | 56.18 | 0.47 | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000163C | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2001-2005 | 2001 | | NULL | 2013-06-05 00:00:00 | NULL | NULL | NULL | 77 | NULL | NULL | NULL | | | D | B | 179.08 | 7.95 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | non traversant | NULL | NULL | NULL | 0 | [ "sud" ] | NULL | ITI+ITE | NULL | murs en béton banché | 30 | 54.08 | 46.12 | 54.08 | 0.47 | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000164D | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1974 | | NULL | 2013-06-05 00:00:00 | NULL | NULL | NULL | 95 | NULL | NULL | NULL | | | E | C | 316.45 | 18.46 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0 | 0 | 4.4 | 8.62 | NULL | est ouest | 1.9 | 2.2 | 0.38 | 1 | [ "est", "ouest" ] | 0.164 | non isole | NULL | | 0 | 66.5 | 66.5 | 66.5 | 2 | | | | non isole | dalle béton | 51.3 | 51.3 | 0.37 | NULL | | | | non isole | dalle béton | 51.3 | 51.3 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000165E | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2006-2012 | 2006 | | NULL | 2013-06-05 00:00:00 | NULL | NULL | NULL | 120 | NULL | NULL | NULL | | | C | D | 91 | 21 | individuel | gaz | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0.58 | 9.96 | 0 | 2.87 | NULL | tout venant | 2.7 | NULL | 0.51 | 1 | [ "est", "est ou ouest", "nord", "sud" ] | 0.129 | ITE | NULL | murs en blocs de béton creux | 20 | 138.62 | 138.62 | 138.62 | 0.45 | | | | ITE | plancher lourd type entrevous terre-cuite, poutrelles béton | 120 | 60 | 0.36 | NULL | | | | ITI | plafond bois sous solives bois | 120 | 60 | 0.18 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000166F | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2001-2005 | 2005 | | NULL | 2013-06-05 00:00:00 | NULL | NULL | NULL | 47 | NULL | NULL | NULL | | | D | B | 189.17 | 7.49 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 1.6 | 0 | 1.6 | 5.8 | NULL | tout venant | 2.2 | NULL | 0.44 | 0 | [ "est", "nord", "ouest" ] | 0.28 | ITI | NULL | murs en béton banché | 25 | 24.9 | 23.13 | 24.9 | 0.4 | | | | | | NULL | NULL | NULL | NULL | | | | | dalle béton | 46.75 | 46.75 | 0.27 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000169I | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2013-06-06 00:00:00 | NULL | NULL | NULL | 67 | NULL | NULL | NULL | | | C | A | 111 | 4 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | métal avec rupture de pont thermique | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 7.6 | 0 | 0 | NULL | non traversant | 2.4 | 2.8 | 0.48 | 1 | [ "sud" ] | 0.2 | ITI | NULL | murs en béton banché | 20 | 40.5 | 30.4 | 40.5 | 0.36 | | | | non isole | dalle béton | 67.48 | 0 | 2 | NULL | | | | non isole | dalle béton | 67.48 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000170A | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2013-06-06 00:00:00 | NULL | NULL | NULL | 77 | NULL | NULL | NULL | | | D | B | 199 | 9 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0.3 | 12 | 2 | 3.3 | NULL | tout venant | 2.2 | 2.8 | 0.5 | 0 | [ "est", "nord", "ouest", "sud" ] | 0.229 | non isole | NULL | murs en pierre de taille et moellons avec remplissage tout venant | 50 | 59.4 | 59.4 | 59.4 | 1.9 | | | | non isole | | 76 | 76 | 0.37 | NULL | | | | ITI | plafond bois sous solives bois | 76 | 76 | 0.3 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000172C | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2001-2005 | 2003 | | NULL | 2013-06-06 00:00:00 | NULL | NULL | NULL | 36 | NULL | NULL | NULL | | | D | B | 196.08 | 7.48 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | métal avec rupture de pont thermique | argon ou krypton | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 1.66 | 5.44 | 0 | 0 | NULL | non traversant | 1.8 | 1.8 | 0.48 | 0 | [ "nord", "sud" ] | NULL | ITI | NULL | murs en blocs de béton creux | 25 | 4.19 | 0 | 4.19 | 0.47 | | | | ITI | dalle béton | 23.9 | 23.9 | 0.43 | NULL | | | | ITI | combles aménagés sous rampant | 23.9 | 23.9 | 0.3 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000177H | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 2000 | | NULL | 2013-06-06 00:00:00 | NULL | NULL | NULL | 130 | NULL | NULL | NULL | | | C | D | 107 | 32 | individuel | fioul | chaudiere fioul basse temperature | | | | | 0 | NULL | NULL | | | | | | chaudiere fioul basse temperature | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.7 | 2.6 | 2.75 | 0 | | 0.124 | ITI | NULL | murs en blocs de béton creux | 20 | 146.54 | 72.38 | 146.54 | 0.35 | | | | ITE | plancher à entrevous isolant | 118.6 | 118.6 | 0.61 | NULL | | | | | combles aménagés sous rampant | 118.8 | 118.8 | 0.3 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000179J | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1960 | | NULL | 2013-06-06 00:00:00 | NULL | NULL | NULL | 51 | NULL | NULL | NULL | | | E | C | 250.59 | 18.65 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | simple vitrage | bois | | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 0 | 15.84 | 5.7 | NULL | est ouest | 1.4 | 1.4 | 0.56 | 1 | [ "est", "ouest" ] | NULL | non isole | NULL | murs en blocs de béton pleins | 33 | 32.92 | 0 | 32.92 | 2 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000181C | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-06-06 00:00:00 | NULL | NULL | NULL | 49 | NULL | NULL | NULL | | | D | B | 208 | 9 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 0 | 0 | 0 | 7.8 | NULL | non traversant | 2.4 | 3 | 0.51 | 0 | [ "est" ] | 0.355 | ITI | NULL | murs en béton banché | 20 | 34.2 | 14.2 | 34.2 | 0.43 | | | | non isole | dalle béton | 48.58 | 0 | 2 | NULL | | | | non isole | dalle béton | 48.58 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000184 | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1952 | | NULL | 2013-06-06 00:00:00 | NULL | NULL | NULL | 43 | NULL | NULL | NULL | | | D | D | 158.43 | 26.31 | individuel | gaz | chaudiere gaz standard | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | individuel | | chauffe-eau gaz independant | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | argon ou krypton | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 0 | 6.19 | 0 | NULL | non traversant | 1.5 | 1.5 | 0.44 | 0 | [ "ouest", "sud" ] | NULL | non isole | NULL | murs en briques pleines doubles avec lame d'air | 25 | 27.58 | 0 | 16.76 | 1.85 | | | | | | NULL | NULL | NULL | NULL | | | | non isole | plafond bois sous solives bois | 43 | 43 | 2.3 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000186H | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-06-06 00:00:00 | NULL | NULL | NULL | 56 | NULL | NULL | NULL | | | D | B | 203 | 9 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | métal avec rupture de pont thermique | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 3.72 | 5.53 | 0 | 0 | NULL | nord sud | 3 | 3.5 | 0.48 | 1 | [ "nord", "sud" ] | 0.313 | non isole | NULL | murs en briques pleines doubles avec lame d'air | 30 | 27.11 | 20.31 | 27.11 | 1.65 | | | | non isole | dalle béton | 55.92 | 0 | 2 | NULL | | | | non isole | dalle béton | 55.92 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000187I | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1975-1977 | 1975 | | NULL | 2013-06-06 00:00:00 | NULL | NULL | NULL | 65 | NULL | NULL | NULL | | | C | A | 131 | 5 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « avant 1982 » | | double vitrage | métal sans rupture de pont thermique | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 4.14 | 7.51 | 0 | 0 | NULL | nord sud | 3.1 | NULL | 0.57 | 1 | [ "nord", "sud" ] | 0.411 | ITI | NULL | murs en béton banché | 20 | 31.44 | 16.72 | 31.44 | 1.11 | | | | non isole | dalle béton | 65 | 0 | 2 | NULL | | | | non isole | dalle béton | 65 | 0 | 2.5 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000189K | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-06-06 00:00:00 | NULL | NULL | NULL | 47 | NULL | NULL | NULL | | | D | C | 226 | 12 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | bois | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 4.5 | 4 | 0 | 0 | NULL | nord sud | 2.7 | 3.1 | 0.47 | 0 | [ "nord", "sud" ] | 0.283 | non isole | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 40 | 29.7 | 21.5 | 29.7 | 2 | | | | non isole | plancher entre solives bois avec ou sans remplissage | 47.25 | 0 | 1.1 | NULL | | | | non isole | plafond entre solives bois avec ou sans remplissage | 47.25 | 0 | 1.2 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000190C | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-06-07 00:00:00 | NULL | NULL | NULL | 25 | NULL | NULL | NULL | | | G | D | 597 | 34 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 0 | 3.8 | NULL | non traversant | 2.1 | 2.6 | 0.44 | 0 | [ "est" ] | 0.1 | ITI | NULL | murs en briques pleines doubles avec lame d'air | 35 | 46.5 | 34.15 | 40.8 | 2 | | | | | plancher avec ou sans remplissage | 24.54 | 0 | 1.45 | NULL | | | | ITI | plafond avec ou sans remplissage sous combles | 24.54 | 24.54 | 0.19 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000191D | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2006-2012 | 2006 | | NULL | 2013-06-07 00:00:00 | NULL | NULL | NULL | 119 | NULL | NULL | NULL | | | C | A | 100.15 | 4.82 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ecs thermodynamique electrique(pac ou ballon) | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit avec entrées d’air hygroréglables | | double vitrage | pvc | air sec | | NULL | 0 | 2.94 | 8.22 | 1.2 | 0.28 | NULL | tout venant | 2.6 | 2.6 | NULL | 0 | [ "est", "nord", "ouest", "sud" ] | 0.154 | ITI | NULL | murs en blocs de béton creux | 20 | 102.88 | 69.18 | 102.88 | 0.35 | | | | ITE | plancher à entrevous isolant | 120 | 120 | 0.14 | NULL | | | | isole | plafond bois sous solives bois | 120 | 120 | 0.18 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000194G | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2001-2005 | 2001 | | NULL | 2013-06-07 00:00:00 | NULL | NULL | NULL | 30 | NULL | NULL | NULL | | | D | B | 225 | 8 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | métal avec rupture de pont thermique | | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0 | 0 | 0 | 4.75 | NULL | non traversant | 3 | 3.6 | 0.52 | 0 | [ "est" ] | 0.198 | ITI | NULL | murs en béton banché | 20 | 22.85 | 19.25 | 22.85 | 0.35 | | | | non isole | dalle béton | 30.08 | 0 | 2 | NULL | | | | ITE | dalle béton | 30.08 | 30.08 | 0.15 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000197 | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1952 | | NULL | 2013-06-07 00:00:00 | NULL | NULL | NULL | 43 | NULL | NULL | NULL | | | D | D | 158.43 | 26.31 | individuel | gaz | chaudiere gaz standard | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | individuel | | chauffe-eau gaz independant | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | argon ou krypton | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 0 | 6.19 | 0 | NULL | non traversant | 1.5 | 1.5 | 0.44 | 0 | [ "ouest", "sud" ] | NULL | non isole | NULL | murs en briques pleines doubles avec lame d'air | 25 | 27.58 | 0 | 16.76 | 1.85 | | | | | | NULL | NULL | NULL | NULL | | | | non isole | plafond bois sous solives bois | 43 | 43 | 2.3 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000198K | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-06-07 00:00:00 | NULL | NULL | NULL | 69 | NULL | NULL | NULL | | | C | B | 146 | 7 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « avant 1982 » | | double vitrage | métal sans rupture de pont thermique | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 5 | 12 | 0 | 0.4 | NULL | tout venant | 3.3 | NULL | 0.57 | 1 | [ "est", "nord", "sud" ] | 0.29 | ITI | NULL | murs en pan de bois sans remplissage tout venant | 8 | 53.5 | 42.6 | 53.5 | 0.35 | | | | non isole | plancher lourd type entrevous terre-cuite, poutrelles béton | 69.47 | 10 | 2 | NULL | | | | non isole | plafond lourd type entrevous terre-cuite, poutrelles béton | 69.47 | 0 | 2.5 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000199L | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1959 | | NULL | 2013-06-07 00:00:00 | NULL | NULL | NULL | 42 | NULL | NULL | NULL | | | D | E | 228.94 | 53.57 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | gaz | chaudiere gaz standard | | 1 | NULL | NULL | 0 | Puits canadien | | simple vitrage | bois | | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 3.94 | 7.13 | 0 | NULL | est ouest | 3.8 | NULL | 0.48 | 0 | [ "ouest", "sud" ] | 0.357 | ITI | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 25 | 33.97 | 19.98 | 33.97 | 0.98 | | | | non isole | plancher lourd type entrevous terre-cuite, poutrelles béton | 41.74 | 41.74 | 2 | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000201V | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1964 | | NULL | 2013-06-07 00:00:00 | NULL | NULL | NULL | 68 | NULL | NULL | NULL | | | E | C | 258.33 | 14.01 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | non traversant | NULL | NULL | NULL | 0 | [ "sud" ] | NULL | non isole | NULL | | 0 | 45.9 | 24.57 | 45.9 | 2 | | | | non isole | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000202W | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1964 | | NULL | 2013-06-07 00:00:00 | NULL | NULL | NULL | 55 | NULL | NULL | NULL | | | E | C | 312.35 | 16.89 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0 | 1.92 | 8.27 | 0.88 | NULL | tout venant | 1.9 | 2.2 | 0.35 | 1 | [ "est", "indetermine", "ouest", "sud" ] | 0.248 | non isole | NULL | | 0 | 53.41 | 39.39 | 53.41 | 2 | | | | non isole | dalle béton | NULL | NULL | NULL | NULL | | | | non isole | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000203X | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1964 | | NULL | 2013-06-07 00:00:00 | NULL | NULL | NULL | 55 | NULL | NULL | NULL | | | F | D | 418.88 | 24.67 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | non traversant | NULL | NULL | NULL | 0 | [ "nord" ] | NULL | non isole | NULL | | 0 | 52.37 | 38.78 | 52.37 | 2 | | | | non isole | dalle béton | NULL | NULL | NULL | NULL | | | | non isole | dalle béton | 55 | 55 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000205@ | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1989-2000 | 1990 | | NULL | 2013-06-07 00:00:00 | NULL | NULL | NULL | 28 | NULL | NULL | NULL | | | D | B | 198.9 | 6.76 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 5.01 | 0 | 0 | 0 | NULL | non traversant | 1.5 | 1.5 | 0.44 | 0 | [ "nord" ] | NULL | non isole | NULL | murs en béton banché | 25 | 28.71 | 0 | 12.8 | 0.5 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1000206A | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-06-07 00:00:00 | NULL | NULL | NULL | 36 | NULL | NULL | NULL | | | E | C | 285 | 13 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 1.25 | 0 | 0 | 0 | NULL | est ouest | 2.5 | NULL | 0.44 | 1 | [ "est ou ouest", "nord" ] | 0.188 | non isole | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 50 | 30.05 | 16.21 | 30.05 | 2 | | | | non isole | plancher bois sur solives bois | 36.1 | 10.32 | 1.6 | NULL | | | | ITI | plafond bois sur solives bois | 38.98 | 38.98 | 0.33 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |