| 1313N1001681B | 13 | 0 | dpe arrêté 2012 facture logement | maison | 2013-2021 | 2013 | | NULL | 2013-12-20 00:00:00 | NULL | NULL | NULL | 95 | NULL | NULL | NULL | | | C | A | 138.3 | 5.23 | | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | argon ou krypton | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en blocs de béton creux | NULL | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | NULL | | | | ITI | | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313N1001828E | 13 | 0 | dpe arrêté 2012 facture immeuble | immeuble | 2013-2021 | 2013 | | NULL | 2014-07-07 00:00:00 | NULL | NULL | 706 | NULL | NULL | NULL | NULL | | | A | C | 47.54 | 11.13 | | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | argon ou krypton | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en blocs de béton creux | NULL | NULL | NULL | NULL | NULL | | | | isole | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | plafond en plaque de plâtre | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313N1001829F | 13 | 0 | dpe arrêté 2012 facture immeuble | immeuble | 2013-2021 | 2013 | | NULL | 2014-07-07 00:00:00 | NULL | NULL | 972 | NULL | NULL | NULL | NULL | | | A | B | 43.16 | 10.1 | | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | argon ou krypton | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en blocs de béton creux | NULL | NULL | NULL | NULL | NULL | | | | isole | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | plafond en plaque de plâtre | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313N1001830X | 13 | 0 | dpe arrêté 2012 facture immeuble | immeuble | 2013-2021 | 2013 | | NULL | 2014-07-07 00:00:00 | NULL | NULL | 706 | NULL | NULL | NULL | NULL | | | A | C | 47.54 | 11.13 | | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | argon ou krypton | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en blocs de béton creux | NULL | NULL | NULL | NULL | NULL | | | | isole | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | plafond en plaque de plâtre | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313N1001831Y | 13 | 0 | dpe arrêté 2012 facture immeuble | immeuble | 2013-2021 | 2013 | | NULL | 2014-07-07 00:00:00 | NULL | NULL | 706 | NULL | NULL | NULL | NULL | | | A | C | 47.54 | 11.13 | | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | argon ou krypton | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en blocs de béton creux | NULL | NULL | NULL | NULL | NULL | | | | isole | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | plafond en plaque de plâtre | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313N1001832@ | 13 | 0 | dpe arrêté 2012 facture immeuble | immeuble | 2013-2021 | 2013 | | NULL | 2014-07-07 00:00:00 | NULL | NULL | 972 | NULL | NULL | NULL | NULL | | | A | B | 43.16 | 10.1 | | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | argon ou krypton | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en blocs de béton creux | NULL | NULL | NULL | NULL | NULL | | | | isole | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | plafond en plaque de plâtre | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313N1001833A | 13 | 0 | dpe arrêté 2012 facture logement | maison | 2013-2021 | 2013 | | NULL | 2016-09-09 00:00:00 | NULL | NULL | NULL | 60 | NULL | NULL | NULL | | | D | A | 157.04 | 5.47 | | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | | pvc | | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | | NULL | | NULL | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | NULL | | | | | plafond avec ou sans remplissage sous combles | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000001U | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2013-04-08 00:00:00 | NULL | NULL | NULL | 84 | NULL | NULL | NULL | | | D | B | 206 | 10 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 4.6 | 7.4 | 0 | 1.35 | NULL | tout venant | 2.6 | NULL | 0.48 | 0 | [ "est", "nord", "sud" ] | 0.175 | ITI | NULL | murs en briques pleines doubles avec lame d'air | 30 | 63.15 | 63.15 | 63.15 | 0.32 | | | | | | 84 | 0 | 0.36 | NULL | | | | | plafond avec ou sans remplissage sous combles | NULL | NULL | NULL | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000002V | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1989 | | NULL | 2013-04-11 00:00:00 | NULL | NULL | NULL | 136 | NULL | NULL | NULL | | | C | D | 107 | 32 | individuel | fioul | chaudiere fioul standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere fioul standard | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 2.34 | 11.88 | 1.85 | 1.38 | NULL | tout venant | 2.5 | 3.1 | 0.47 | 0 | [ "est", "nord", "ouest", "sud" ] | 0.103 | ITI | NULL | murs en blocs de béton creux | 20 | 160.9 | 152.4 | 160.9 | 0.5 | | | | ITE | plancher lourd type entrevous terre-cuite, poutrelles béton | 70 | 70 | 0.61 | NULL | | | | ITI | plafond bois sous solives bois | 143 | 73 | 0.18 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000005Y | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1989-2000 | 1989 | | NULL | 2013-04-15 00:00:00 | NULL | NULL | NULL | 23 | NULL | NULL | NULL | | | D | B | 214 | 7 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | métal avec rupture de pont thermique | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 3.09 | 0 | 0 | 0 | NULL | non traversant | 3 | 3.7 | 0.48 | 0 | [ "nord" ] | 0.247 | non isole | NULL | murs en béton banché | 20 | 19.91 | 9.41 | 19.91 | 0.43 | | | | non isole | | 22.64 | 0 | 2 | NULL | | | | non isole | dalle béton | 22.64 | 0 | 2.5 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000007A | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1989-2000 | 1989 | | NULL | 2013-04-19 00:00:00 | NULL | NULL | NULL | 83 | NULL | NULL | NULL | | | D | B | 196 | 9 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | métal sans rupture de pont thermique | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 1.8 | 0 | 4.9 | 1.8 | NULL | tout venant | 3.3 | NULL | 0.54 | 0 | [ "est", "nord", "ouest" ] | 0.122 | ITI | NULL | murs en béton banché | 20 | 61.1 | 61.1 | 61.1 | 0.5 | | | | | dalle béton | 83.23 | 0 | 0.67 | NULL | | | | non isole | dalle béton | 83 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000008B | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-04-19 00:00:00 | NULL | NULL | NULL | 69 | NULL | NULL | NULL | | | G | D | 492 | 29 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 10.65 | 4.64 | NULL | est ouest | 2.4 | 3 | 0.44 | 1 | [ "est", "ouest" ] | 0.385 | ITI | NULL | | 0 | 90.8 | 24.39 | 24.39 | 2 | | | | | | NULL | NULL | NULL | NULL | | | | non isole | | 68.67 | 68.67 | 2.5 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000009C | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2006-2012 | 2006 | | NULL | 2013-04-22 00:00:00 | NULL | NULL | NULL | 100 | NULL | NULL | NULL | | | D | D | 226 | 30 | individuel | gaz | chaudiere gaz basse temperature | | bois | poele ou insert bois | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | 0 | Extracteur mécanique sur conduit non modifié de ventilation naturelle existante | | double vitrage | pvc | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 1.2 | 3.6 | 0 | 0 | NULL | non traversant | 2.5 | 2.9 | 0.48 | 0 | [ "nord", "sud" ] | 0.048 | ITI | NULL | murs en blocs de béton creux | 20 | 113.51 | 95.2 | 113.51 | 0.62 | | | | ITE | plancher lourd type entrevous terre-cuite, poutrelles béton | 100 | 100 | 1 | NULL | | | | ITI | plafond bois sous solives bois | 100 | 100 | 0.13 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000011V | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1983-1988 | 1983 | | NULL | 2013-04-24 00:00:00 | NULL | NULL | NULL | 94 | NULL | NULL | NULL | | | D | C | 217 | 12 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 6.03 | 9 | 0 | 0 | NULL | nord sud | 2.4 | 2.9 | 0.47 | 0 | [ "nord", "sud" ] | 0.121 | ITI | NULL | murs en blocs de béton creux | 23 | 146.79 | 109.28 | 146.79 | 0.78 | | | | ITE | | 49 | 49 | 0.37 | NULL | | | | ITI | plafond bois sous solives bois | 49 | 49 | 0.15 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000017B | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1960 | | NULL | 2013-04-25 00:00:00 | NULL | NULL | NULL | 61 | NULL | NULL | NULL | | | C | D | 143.96 | 33.69 | individuel | gaz | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | gaz | chaudiere gaz basse temperature | | 1 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 8.43 | 9.79 | NULL | est ouest | 2.2 | 2.6 | 0.46 | 1 | [ "est", "ouest" ] | 0.469 | non isole | NULL | murs en béton banché | 30 | 20.62 | 20.62 | 20.62 | 2 | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000024@ | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1950 | | NULL | 2013-04-26 00:00:00 | NULL | NULL | NULL | 46 | NULL | NULL | NULL | | | E | C | 255.24 | 12.77 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 13.34 | 0 | NULL | non traversant | 3.5 | 4.7 | 0.52 | 0 | [ "indetermine", "ouest" ] | 0.568 | non isole | NULL | murs en béton banché | 35 | 23.64 | 11.66 | 23.64 | 2 | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000025A | 13 | 0 | dpe arrêté 2012 facture logement | appartement | avant 1948 | 1900 | | NULL | 2013-04-26 00:00:00 | NULL | NULL | NULL | 36 | NULL | NULL | NULL | | | N | N | 0 | 0 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | bois | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | non traversant | NULL | NULL | NULL | 0 | [ "est" ] | NULL | ITI | NULL | murs en pierre de taille et moellons avec remplissage tout venant | NULL | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000026B | 13 | 0 | dpe arrêté 2012 facture logement | appartement | avant 1948 | 1900 | | NULL | 2013-04-26 00:00:00 | NULL | NULL | NULL | 40 | NULL | NULL | NULL | | | N | N | 0 | 0 | individuel | gaz | radiateurs gaz | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | | | simple vitrage | bois | | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | non traversant | NULL | NULL | NULL | 0 | [ "est" ] | NULL | ITI | NULL | murs en briques pleines simples | NULL | NULL | NULL | NULL | NULL | | | | ITI | | NULL | NULL | NULL | NULL | | | | ITI | | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000027C | 13 | 0 | dpe arrêté 2012 facture logement | appartement | avant 1948 | 1900 | | NULL | 2013-04-26 00:00:00 | NULL | NULL | NULL | 40 | NULL | NULL | NULL | | | N | N | 0 | 0 | | | | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | simple vitrage | bois | | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | non traversant | NULL | NULL | NULL | 0 | [ "est" ] | NULL | ITI | NULL | murs en briques pleines simples | NULL | NULL | NULL | NULL | NULL | | | | ITI | | NULL | NULL | NULL | NULL | | | | ITI | plafond avec ou sans remplissage sous combles | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000030W | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2006-2012 | 2006 | | NULL | 2013-04-30 00:00:00 | NULL | NULL | NULL | 116 | NULL | NULL | NULL | | | C | B | 142 | 6 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 1.34 | 0 | 10.85 | 6.7 | NULL | tout venant | 1.8 | 2.2 | 0.38 | 0 | [ "est", "nord", "ouest" ] | 0.144 | ITI | NULL | murs en blocs de béton creux | 25 | 135.19 | 112.69 | 135.19 | 0.38 | | | | ITE | plancher à entrevous isolant | 62 | 62 | 0.26 | NULL | | | | | plafond bois sous solives bois | 62 | 62 | 0.25 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000031X | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1960 | | NULL | 2013-04-30 00:00:00 | NULL | NULL | NULL | 24 | NULL | NULL | NULL | | | E | C | 278.2 | 13 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | | NULL | 0 | 0 | 0 | 0 | 0 | NULL | est ouest (faible) | NULL | NULL | NULL | 1 | [ "ouest", "sud" ] | 0 | non isole | NULL | murs en béton banché | 35 | 19.87 | 17.57 | 19.87 | 2 | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000032Y | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1960 | | NULL | 2013-04-30 00:00:00 | NULL | NULL | NULL | 79 | NULL | NULL | NULL | | | D | B | 162.21 | 8.47 | individuel | gaz | chaudiere gaz standard | | electricite | generateurs a effet joule | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 0 | 10.64 | 10.63 | NULL | est ouest | 4 | 4.7 | 0.52 | 0 | [ "est", "ouest" ] | 0.705 | non isole | NULL | murs en béton banché | 30 | 20.46 | 8.92 | 20.46 | 2 | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000033@ | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1964 | | NULL | 2013-04-30 00:00:00 | NULL | NULL | NULL | 53 | NULL | NULL | NULL | | | E | F | 315.53 | 56.06 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 8.26 | 9.79 | 0 | 0 | NULL | nord sud | 3.8 | 4.5 | 0.48 | 1 | [ "nord", "sud" ] | 0.328 | non isole | NULL | murs en béton banché | 30 | 44.76 | 36.97 | 44.76 | 2 | | | | non isole | dalle béton | 56.83 | 56.83 | 2 | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000035B | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1975-1977 | 1975 | | NULL | 2013-05-01 00:00:00 | NULL | NULL | NULL | 66 | NULL | NULL | NULL | | | D | E | 197 | 46 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 2 | 0 | 9.16 | 0 | NULL | non traversant | 2.5 | 3.3 | 0.51 | 0 | [ "nord", "ouest" ] | 0.259 | ITI | NULL | | 0 | 68.96 | 31.94 | 42.66 | 1.11 | | | | non isole | dalle béton | 66.08 | 0 | 2 | NULL | | | | non isole | dalle béton | 66.08 | 0 | 2.5 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000037D | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2008 | | NULL | 2013-05-02 00:00:00 | NULL | NULL | NULL | 60 | NULL | NULL | NULL | | | C | A | 102 | 3 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | métal avec rupture de pont thermique | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 1.15 | 0 | 0 | 5.86 | NULL | non traversant | 2.4 | 3.1 | 0.41 | 1 | [ "est", "nord" ] | 0.164 | ITI | NULL | murs en béton banché | 20 | 48.65 | 35.72 | 48.65 | 0.36 | | | | non isole | dalle béton | 59.58 | 0 | 2 | NULL | | | | non isole | dalle béton | 59.58 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000038E | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1966 | | NULL | 2013-05-02 00:00:00 | NULL | NULL | NULL | 32 | NULL | NULL | NULL | | | E | C | 257 | 12 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0 | 8.29 | 0 | 0 | NULL | non traversant | 3.5 | 4.7 | 0.52 | 1 | [ "sud" ] | 0.505 | non isole | NULL | murs en briques pleines doubles avec lame d'air | 30 | 46.27 | 8.11 | 19.71 | 1.65 | | | | non isole | | 31.83 | 0 | 2 | NULL | | | | non isole | dalle béton | 31.83 | 0 | 2.5 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000040X | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2001-2005 | 2003 | | NULL | 2013-05-03 00:00:00 | NULL | NULL | NULL | 137 | NULL | NULL | NULL | | | B | A | 89.05 | 2.96 | individuel | electricite | pac geothermique | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Extracteur mécanique sur conduit non modifié de ventilation naturelle existante | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 2.47 | 8.8 | 0 | 1.96 | NULL | tout venant | 1.9 | 2.2 | 0.38 | 0 | [ "est", "nord", "sud" ] | 0.076 | ITI | NULL | murs en blocs de béton creux | 20 | 175.45 | 161.31 | 175.45 | 0.35 | | | | ITI | plancher avec ou sans remplissage | 78 | 78 | 0.37 | NULL | | | | ITI | combles aménagés sous rampant | 75.26 | 75.26 | 0.19 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000042@ | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1960 | | NULL | 2013-05-03 00:00:00 | NULL | NULL | NULL | 160 | NULL | NULL | NULL | | | F | G | 341.85 | 102.56 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | collectif | | ecs solaire | | gaz | chaudiere gaz standard | | 1 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0.75 | 10.83 | 16.25 | 4.58 | NULL | tout venant | 4 | 4.7 | 0.52 | 1 | [ "est", "nord", "ouest", "sud" ] | 0.078 | ITE | NULL | murs en blocs de béton pleins | 33 | 437.73 | 380.76 | 437.73 | 0.59 | | | | non isole | plancher lourd type entrevous terre-cuite, poutrelles béton | 111.62 | 111.62 | 2 | NULL | | | | ITI | dalle béton | 107.96 | 107.96 | 0.2 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000043A | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2006-2012 | 2008 | | NULL | 2013-05-03 00:00:00 | NULL | NULL | NULL | 127 | NULL | NULL | NULL | | | C | A | 113.67 | 4.76 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | métal avec rupture de pont thermique | argon ou krypton | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 7.96 | 9.07 | 7.08 | 6.56 | NULL | tout venant | 1.8 | 1.8 | 0.48 | 0 | [ "est", "nord", "ouest", "sud" ] | 0.564 | ITI | NULL | murs en blocs de béton creux | 20 | 112.13 | 23.71 | 112.13 | 0.4 | | | | ITE | dalle béton | 83 | 83 | 0.36 | NULL | | | | ITI | plafond en plaque de plâtre | 80.87 | 80.87 | 0.19 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000046D | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2006-2012 | 2006 | | NULL | 2013-05-03 00:00:00 | NULL | NULL | NULL | 136 | NULL | NULL | NULL | | | C | B | 145 | 7 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 9.37 | 0 | 18.75 | 4.02 | NULL | tout venant | 2.1 | 2.6 | 0.44 | 0 | [ "est", "nord", "ouest" ] | 0.284 | ITI | NULL | murs en blocs de béton creux | 20 | 93.66 | 80.96 | 93.66 | 0.4 | | | | ITE | plancher à entrevous isolant | 111 | 111 | 0.43 | NULL | | | | ITI | plafond bois sous solives bois | 113 | 113 | 0.25 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000047E | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2013-05-03 00:00:00 | NULL | NULL | NULL | 65 | NULL | NULL | NULL | | | F | D | 384 | 22 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 1.25 | 1.1 | 1 | 1 | NULL | tout venant | 3.5 | 2.6 | 0.44 | 0 | [ "est", "nord", "ouest", "sud" ] | 0.081 | ITI | NULL | murs en blocs de béton creux | 20 | 69.65 | 49.65 | 69.65 | 0.62 | | | | non isole | plancher bois sur solives bois | 65 | 65 | 1.6 | NULL | | | | ITI | plafond bois sous solives bois | 65 | 65 | 0.18 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000051@ | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-05-05 00:00:00 | NULL | NULL | NULL | 68 | NULL | NULL | NULL | | | C | D | 149 | 23 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | simple vitrage | bois | | | NULL | 0 | 10 | 0 | 0 | 0 | NULL | non traversant | 4.7 | 4.7 | 0.52 | 0 | [ "nord" ] | 0.303 | non isole | NULL | murs en blocs de béton creux | 23 | 39 | 23 | 39 | 2 | | | | non isole | dalle béton | 68.26 | 0 | 2 | NULL | | | | non isole | dalle béton | 68.26 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000052A | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-05-06 00:00:00 | NULL | NULL | NULL | 84 | NULL | NULL | NULL | | | E | C | 294 | 17 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | métal sans rupture de pont thermique | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 8.8 | 3.2 | 0 | 0 | NULL | nord sud | 3.4 | NULL | 0.49 | 0 | [ "nord", "sud" ] | 0.253 | non isole | NULL | murs en pierre de taille et moellons avec remplissage tout venant | 60 | 90 | 35.5 | 63.5 | 1.6 | | | | non isole | voutains en briques ou moellons | 67.5 | 67.5 | 0.8 | NULL | | | | non isole | plafond entre solives bois avec ou sans remplissage | 67.5 | 0 | 1.2 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000053B | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2006-2012 | 2007 | | NULL | 2013-05-06 00:00:00 | NULL | NULL | NULL | 75 | NULL | NULL | NULL | | | C | A | 137.11 | 4.4 | individuel | electricite | pac air/air | | electricite | chaudiere electrique | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 4.14 | 6.69 | 0 | 0 | NULL | nord sud | 1.9 | 2.2 | 0.48 | 0 | [ "nord", "sud" ] | 0.223 | ITI | NULL | murs en blocs de béton creux | 20 | 37.63 | 37.63 | 37.63 | 0.4 | | | | ITE | dalle béton | 40.48 | 40.48 | 0.27 | NULL | | | | ITI | plafond en plaque de plâtre | 40.48 | 40.48 | 0.19 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000054C | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1990 | | NULL | 2013-05-06 00:00:00 | NULL | NULL | NULL | 87 | NULL | NULL | NULL | | | D | B | 194.56 | 7.47 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 7.31 | 3.04 | 0 | 0 | NULL | nord sud | 2.5 | 3.1 | 0.47 | 1 | [ "nord", "sud" ] | 0.098 | ITI | NULL | murs en blocs de béton creux | 20 | 120.2 | 95.56 | 120.2 | 0.62 | | | | ITE | plancher à entrevous isolant | 45.91 | 45.91 | 0.61 | NULL | | | | ITI | plafond en plaque de plâtre | 45.91 | 45.91 | 0.3 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000055D | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2006-2012 | 2008 | | NULL | 2013-05-06 00:00:00 | NULL | NULL | NULL | 111 | NULL | NULL | NULL | | | C | A | 114.87 | 3.79 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | argon ou krypton | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 6.71 | 7.32 | 0 | 1.82 | NULL | tout venant | 1.9 | NULL | 0.38 | 0 | [ "est", "nord", "sud" ] | 0.099 | ITI | NULL | murs en blocs de béton creux | 20 | 143.87 | 143.87 | 143.87 | 0.38 | | | | ITE | plancher à entrevous isolant | 62.87 | 62.87 | 0.45 | NULL | | | | ITI | plafond en plaque de plâtre | 57.82 | 57.82 | 0.15 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000056E | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2007 | | NULL | 2013-05-06 00:00:00 | NULL | NULL | NULL | 71 | NULL | NULL | NULL | | | D | B | 163.51 | 6.27 | individuel | electricite | chaudiere electrique | | electricite | generateurs a effet joule | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 1.82 | 4.14 | 4.86 | 0 | NULL | tout venant | 1.9 | 2.2 | 0.48 | 1 | [ "nord", "ouest", "sud" ] | 0.157 | ITI | NULL | murs en béton banché | 20 | 74.72 | 58.26 | 74.72 | 0.4 | | | | non isole | dalle béton | NULL | NULL | NULL | NULL | | | | ITE | dalle béton | 71 | 71 | 0.25 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000057F | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1993 | | NULL | 2013-05-06 00:00:00 | NULL | NULL | NULL | 124 | NULL | NULL | NULL | | | D | B | 187 | 10 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0 | 4.8 | 4.36 | 4.39 | NULL | tout venant | 2.2 | 2.6 | 0.44 | 1 | [ "est", "ouest", "sud" ] | 0.095 | ITI | NULL | murs en blocs de béton creux | 20 | 145.55 | 129.55 | 145.55 | 0.42 | | | | ITE | dalle béton | 74 | 74 | 0.37 | NULL | | | | ITI | plafond bois sous solives bois | 72 | 72 | 0.13 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000058G | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-05-06 00:00:00 | NULL | NULL | NULL | 78 | NULL | NULL | NULL | | | E | E | 261 | 49 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | métal sans rupture de pont thermique | | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 19.95 | 0 | 0 | 0 | NULL | non traversant | 4.6 | NULL | 0.6 | 0 | [ "nord" ] | 0.508 | ITI | NULL | murs en béton banché | 35 | 32.13 | 19.3 | 32.13 | 2 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000059H | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2006-2012 | 2006 | | NULL | 2013-05-07 00:00:00 | NULL | NULL | NULL | 86 | NULL | NULL | NULL | | | C | A | 98 | 4 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 1.34 | 7.37 | 8.71 | 0 | NULL | tout venant | 1.8 | 2.6 | 0.44 | 0 | [ "nord", "ouest", "sud" ] | 0.242 | ITI | NULL | murs en blocs de béton creux | 23 | 66.68 | 54.68 | 66.68 | 0.4 | | | | ITE | plancher à entrevous isolant | 86 | 86 | 0.36 | NULL | | | | ITI | plafond avec ou sans remplissage sous combles | 86 | 86 | 0.25 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000062B | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1983-1988 | 1983 | | NULL | 2013-05-08 00:00:00 | NULL | NULL | NULL | 90 | NULL | NULL | NULL | | | D | C | 217 | 11 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 1.24 | 0 | 3.85 | 4.31 | NULL | tout venant | 2.5 | 3.2 | 0.47 | 0 | [ "est", "nord", "ouest" ] | 0.12 | ITI | NULL | murs en blocs de béton creux | 20 | 81.7 | 68.95 | 81.7 | 0.42 | | | | | | 90.09 | 90.09 | 0.78 | NULL | | | | ITI | plafond bois sous solives bois | 90.09 | 90.09 | 0.34 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000063C | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-05-08 00:00:00 | NULL | NULL | NULL | 45 | NULL | NULL | NULL | | | D | E | 184 | 43 | individuel | gaz | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 4.88 | 4.66 | 0 | 0 | NULL | nord sud | 3.5 | 4.7 | 0.52 | 1 | [ "nord", "sud" ] | 0.207 | non isole | NULL | murs en briques pleines doubles avec lame d'air | 20 | 71.6 | 36.58 | 40.64 | 2 | | | | non isole | dalle béton | 44.67 | 0 | 2 | NULL | | | | non isole | dalle béton | 44.67 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000066F | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1983-1988 | 1983 | | NULL | 2013-05-10 00:00:00 | NULL | NULL | NULL | 84 | NULL | NULL | NULL | | | D | E | 185 | 43 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Extracteur mécanique sur conduit non modifié de ventilation naturelle existante | | simple vitrage | bois | | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 10.59 | 9.65 | 0 | 0 | NULL | nord sud | 4 | 4.7 | 0.52 | 0 | [ "nord", "sud" ] | 0.482 | non isole | NULL | murs en béton banché | 22.5 | 37.76 | 21.76 | 37.76 | 2 | | | | non isole | plancher lourd type entrevous terre-cuite, poutrelles béton | 83.75 | 0 | 2 | NULL | | | | non isole | plafond lourd type entrevous terre-cuite, poutrelles béton | 83.75 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000069I | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1962 | | NULL | 2013-05-11 00:00:00 | NULL | NULL | NULL | 125 | NULL | NULL | NULL | | | D | A | 163 | 2 | individuel | bois | chaudiere bois | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | argon ou krypton | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 19.08 | 7.61 | 0 | 0 | NULL | nord sud | 2.2 | 2.6 | 0.46 | 1 | [ "nord", "sud" ] | 0.251 | ITI | NULL | murs en blocs de béton creux | 20 | 104.08 | 79.46 | 104.08 | 0.47 | | | | ITE | dalle béton | 60 | 60 | 0.37 | NULL | | | | ITI | combles aménagés sous rampant | 57.64 | 57.64 | 0.3 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000071B | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1989 | | NULL | 2013-05-11 00:00:00 | NULL | NULL | NULL | 88 | NULL | NULL | NULL | | | D | B | 176 | 9 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 8 | 3.3 | NULL | est ouest | 2.2 | 2.8 | 0.47 | 0 | [ "est", "ouest" ] | NULL | ITI | NULL | | NULL | 59 | 0 | 59 | NULL | | | | | | 45 | 45 | 0.67 | NULL | | | | ITI | plafond bois sous solives bois | 40 | 40 | 0.18 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000078I | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2013-05-13 00:00:00 | NULL | NULL | NULL | 94 | NULL | NULL | NULL | | | D | E | 191 | 44 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 1.34 | 0 | 9.44 | 4.6 | NULL | tout venant | 2.6 | NULL | 0.4 | 0 | [ "est", "nord", "ouest" ] | 0.158 | ITI | NULL | murs en briques pleines doubles avec lame d'air | 20 | 81.77 | 81.77 | 81.77 | 2 | | | | non isole | dalle béton | 94 | 94 | 0.35 | NULL | | | | ITI | plafond avec ou sans remplissage sous combles | 94 | 94 | 0.19 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000079 | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2001-2005 | 2002 | | NULL | 2013-05-13 00:00:00 | NULL | NULL | NULL | 107 | NULL | NULL | NULL | | | C | D | 102 | 23 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | | pvc | | | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en béton banché | 20 | 69.64 | 0 | 69.64 | 0.47 | | | | | | NULL | NULL | NULL | NULL | | | | ITE | dalle béton | 106.51 | 106.51 | 0.3 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000080B | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2001-2005 | 2003 | | NULL | 2013-05-13 00:00:00 | NULL | NULL | NULL | 116 | NULL | NULL | NULL | | | C | D | 113.42 | 24.96 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | electricite | pac air/air | | collectif | | ecs solaire | | gaz | chaudiere gaz condensation | | 1 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 2.72 | 4.29 | 9.92 | 2.11 | NULL | tout venant | 2.2 | 2.6 | 0.44 | 0 | [ "est", "nord", "ouest", "sud" ] | 0.097 | ITI | NULL | murs en blocs de béton pleins | 33 | 178.06 | 178.06 | 178.06 | 0.47 | | | | ITE | plancher à entrevous isolant | 65.55 | 65.55 | 0.43 | NULL | | | | ITI | plafond en plaque de plâtre | 67.23 | 67.23 | 0.34 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000081 | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2001-2005 | 2002 | | NULL | 2013-05-13 00:00:00 | NULL | NULL | NULL | 107 | NULL | NULL | NULL | | | C | D | 102 | 23 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | | pvc | | | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en béton banché | 20 | 69.64 | 0 | 69.64 | 0.47 | | | | | | NULL | NULL | NULL | NULL | | | | ITE | dalle béton | 106.51 | 106.51 | 0.3 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1000084F | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2001-2005 | 2002 | | NULL | 2013-05-13 00:00:00 | NULL | NULL | NULL | 107 | NULL | NULL | NULL | | | C | D | 102 | 23 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | | pvc | | | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en béton banché | 20 | 69.64 | 0 | 69.64 | 0.47 | | | | | | NULL | NULL | NULL | NULL | | | | ITE | dalle béton | 106.51 | 106.51 | 0.3 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |