| 1413V1004658R | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2014-06-10 00:00:00 | NULL | NULL | NULL | 51 | NULL | NULL | NULL | | | C | D | 98 | 23 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0 | 0 | 0 | 10 | NULL | non traversant | 2.2 | 2.6 | 0.44 | 0 | [ "est" ] | 0.556 | non isole | NULL | murs en béton banché | 20 | 46 | 8 | 18 | 2 | | | | non isole | dalle béton | 51 | 0 | 2 | NULL | | | | non isole | dalle béton | 51 | 0 | 2.5 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004661L | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2006-2012 | 2006 | | NULL | 2014-06-10 00:00:00 | NULL | NULL | NULL | 180 | NULL | NULL | NULL | | | C | A | 97.37 | 4.03 | individuel | electricite | pac air/eau | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | métal sans rupture de pont thermique | air sec | | NULL | 0 | 0 | 1 | 5.1 | 22.5 | NULL | non traversant | 4.1 | 4.1 | NULL | 0 | [ "est", "ouest", "sud" ] | 0.143 | ITI | NULL | murs en blocs de béton creux | 20 | 171.9 | 171.9 | 171.9 | 0.4 | | | | ITI | dalle béton | 115 | 115 | 0.36 | NULL | | | | ITI | plafond en plaque de plâtre | 115 | 115 | 0.25 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004664O | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1975-1977 | 1975 | | NULL | 2014-06-11 00:00:00 | NULL | NULL | NULL | 83 | NULL | NULL | NULL | | | B | A | 59 | 5 | individuel | electricite | pac air/air | | bois | poele ou insert bois | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 1.2 | 0 | 8.4 | 2.65 | NULL | tout venant | 2.1 | 2.6 | 0.46 | 1 | [ "est", "nord", "ouest" ] | 0.133 | ITI | NULL | murs en blocs de béton creux | 20 | 98.65 | 79.65 | 98.65 | 0.47 | | | | ITE | dalle béton | 83 | 83 | 0.37 | NULL | | | | ITI | dalle béton | 83 | 83 | 0.19 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004665P | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1989 | | NULL | 2014-06-11 00:00:00 | NULL | NULL | NULL | 150 | NULL | NULL | NULL | | | D | C | 214.6 | 11.83 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 7.44 | 3.6 | 18.27 | NULL | tout venant | 2.6 | 3.2 | 0.47 | 0 | [ "est", "ouest", "sud" ] | NULL | ITI | NULL | murs en blocs de béton creux | NULL | 78.8 | 0 | 78.8 | 0.5 | | | | ITE | | 100 | 100 | 0.35 | NULL | | | | ITI | bardeaux et remplissage | 100 | 100 | 0.3 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004666Q | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2001-2005 | 2005 | | NULL | 2014-06-11 00:00:00 | NULL | NULL | NULL | 83 | NULL | NULL | NULL | | | C | B | 143.74 | 6.04 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 6.94 | 5.25 | 0 | 0 | NULL | nord sud | 2.2 | 2.2 | 0.39 | 1 | [ "nord", "sud" ] | 0.351 | ITI | NULL | murs en béton banché | 20 | 57.81 | 22.5 | 47.81 | 0.47 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004667R | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1978-1982 | 1980 | | NULL | 2014-06-11 00:00:00 | NULL | NULL | NULL | 81 | NULL | NULL | NULL | | | D | B | 167.2 | 6.96 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | bois | air sec | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 0 | 11.45 | 0 | 0 | NULL | non traversant | 3 | 3.2 | 0.57 | 1 | [ "sud" ] | 0.194 | ITI | NULL | murs en béton banché | 20 | 60.84 | 47.58 | 60.84 | 0.43 | | | | | dalle béton | NULL | NULL | NULL | NULL | | | | | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004671M | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1951 | | NULL | 2014-06-11 00:00:00 | NULL | NULL | NULL | 210 | NULL | NULL | NULL | | | E | F | 236.35 | 59.27 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0 | 5.25 | 5.63 | 14.12 | NULL | tout venant | 3.2 | NULL | 0.48 | 0 | [ "est", "indetermine", "ouest", "sud" ] | 0.142 | non isole | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 30 | 225.59 | 187.15 | 225.59 | 2 | | | | | dalle béton | 107 | 107 | 0.34 | NULL | | | | ITI | plafond entre solives bois avec ou sans remplissage | 111 | 111 | 0.3 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004672N | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1978-1982 | 1978 | | NULL | 2014-06-11 00:00:00 | NULL | NULL | NULL | 109 | NULL | NULL | NULL | | | C | D | 107 | 25 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | air sec | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 9.6 | 4.6 | 0 | 0 | NULL | nord sud | 2.2 | 2.7 | 0.44 | 1 | [ "nord", "sud" ] | 0.225 | ITI | NULL | murs en blocs de béton creux | 25 | 49 | 49 | 49 | 0.89 | | | | non isole | dalle béton | 57.42 | 57.42 | 0.37 | NULL | | | | ITI | plafond bois sous solives bois | 51.48 | 51.48 | 0.44 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004674P | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1949 | | NULL | 2014-06-11 00:00:00 | NULL | NULL | NULL | 76 | NULL | NULL | NULL | | | F | D | 437.1 | 25.8 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 1.6 | 5.16 | 5.45 | 0 | NULL | tout venant | 2.4 | 2.7 | 0.44 | 0 | [ "nord", "ouest", "sud" ] | 0.125 | non isole | NULL | murs en pierre de taille et moellons avec remplissage tout venant | 50 | 123.59 | 85.2 | 123.59 | 1.9 | | | | non isole | plancher entre solives bois avec ou sans remplissage | 10 | 10 | 1.1 | NULL | | | | non isole | plafond bois sous solives bois | 21.68 | 21.68 | 2.3 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004675Q | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1949 | | NULL | 2014-06-11 00:00:00 | NULL | NULL | NULL | 59 | NULL | NULL | NULL | | | F | D | 376.2 | 31.68 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | collectif | | ecs solaire | | gaz | chauffe-eau gaz independant | | 1 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 4.5 | 4.59 | 0 | 0 | NULL | nord sud | 2 | 2.2 | 0.38 | 0 | [ "nord", "sud" ] | 0.116 | non isole | NULL | murs en pierre de taille et moellons avec remplissage tout venant | 50 | 93.01 | 69.09 | 93.01 | 1.9 | | | | non isole | plancher entre solives bois avec ou sans remplissage | 5 | 5 | 1.1 | NULL | | | | ITI | plafond bois sous solives bois | 58.79 | 58.79 | 0.56 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004676R | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2001-2005 | 2002 | | NULL | 2014-06-11 00:00:00 | NULL | NULL | NULL | 118 | NULL | NULL | NULL | | | D | B | 153 | 6 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 2.58 | 8.4 | 5.03 | 0.6 | NULL | tout venant | 2.2 | 2.6 | 0.44 | 0 | [ "est", "nord", "ouest", "sud" ] | 0.092 | ITI | NULL | murs en blocs de béton creux | 20 | 163.44 | 163.44 | 163.44 | 0.42 | | | | ITE | plancher à entrevous isolant | 76.4 | 76.4 | 0.17 | NULL | | | | ITI | plafond bois sous solives métalliques | 58.7 | 58.7 | 0.19 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004678T | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2014-06-11 00:00:00 | NULL | NULL | NULL | 180 | NULL | NULL | NULL | | | E | E | 234 | 44 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 4.2 | 5.1 | 7 | 6 | NULL | tout venant | 3.4 | 4.7 | 0.52 | 0 | [ "est", "nord", "ouest", "sud" ] | 0.107 | non isole | NULL | murs en pierre de taille et moellons avec remplissage tout venant | 50 | 212.7 | 185.7 | 212.7 | 1.9 | | | | non isole | plancher lourd type entrevous terre-cuite, poutrelles béton | 100 | 100 | 0.37 | NULL | | | | ITI | plafond entre solives bois avec ou sans remplissage | 100 | 100 | 0.3 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004679U | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1970 | | NULL | 2014-06-11 00:00:00 | NULL | NULL | NULL | 168 | NULL | NULL | NULL | | | E | F | 291.31 | 73.67 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | argon ou krypton | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 7.26 | 7.5 | 8.93 | NULL | tout venant | 2.2 | 2.5 | 0.44 | 1 | [ "est", "ouest", "sud" ] | 0.103 | non isole | NULL | murs en blocs de béton creux | 25 | 234.3 | 206.8 | 234.3 | 2 | | | | non isole | plancher lourd type entrevous terre-cuite, poutrelles béton | 157 | 157 | 2 | NULL | | | | ITI | dalle béton | 151 | 151 | 0.34 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004680M | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1983-1988 | 1983 | | NULL | 2014-06-11 00:00:00 | NULL | NULL | NULL | 48 | NULL | NULL | NULL | | | D | C | 222 | 12 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 2 | 2 | 2 | 0 | NULL | tout venant | 2.2 | 2.8 | 0.47 | 0 | [ "nord", "ouest", "sud" ] | 0.125 | ITI | NULL | murs en blocs de béton creux | 20 | 42 | 42 | 42 | 0.78 | | | | ITI | dalle béton | 48 | 48 | 0.78 | NULL | | | | non isole | dalle béton | 48 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004681N | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2006-2012 | 2006 | | NULL | 2014-06-11 00:00:00 | NULL | NULL | NULL | 95 | NULL | NULL | NULL | | | D | B | 166.19 | 6.97 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 1.97 | 10.04 | 1.1 | 8.67 | NULL | tout venant | 2.2 | 2.6 | 0.4 | 0 | [ "est", "nord", "ouest", "sud" ] | 0.237 | ITI | NULL | murs en blocs de béton creux | 20 | 89.83 | 69.95 | 89.83 | 0.35 | | | | ITI | plancher à entrevous isolant | 95 | 95 | 0.17 | NULL | | | | ITI | plafond en plaque de plâtre | 95 | 95 | 0.19 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004683P | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 2000 | | NULL | 2014-06-11 00:00:00 | NULL | NULL | NULL | 89 | NULL | NULL | NULL | | | C | D | 107.41 | 25.13 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | collectif | | ecs solaire | | gaz | chaudiere gaz standard | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 1.69 | 5.19 | 4.3 | NULL | tout venant | 2.2 | NULL | 0.44 | 0 | [ "est", "ouest", "sud" ] | 0.182 | ITI | NULL | murs en blocs de béton creux | 20 | 50.17 | 50.17 | 50.17 | 0.5 | | | | ITE | plancher lourd type entrevous terre-cuite, poutrelles béton | 45 | 45 | 0.43 | NULL | | | | ITI | plafond avec ou sans remplissage | 45 | 45 | 0.3 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004684Q | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2001-2005 | 2001 | | NULL | 2014-06-11 00:00:00 | NULL | NULL | NULL | 100 | NULL | NULL | NULL | | | C | B | 146 | 8 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | bois | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 5.18 | 0.9 | 3.51 | 10.62 | NULL | tout venant | 2.5 | 3 | 0.47 | 0 | [ "est", "nord", "ouest", "sud" ] | 0.188 | ITI | NULL | murs en blocs de béton creux | 25 | 109.34 | 87.18 | 109.34 | 0.34 | | | | non isole | dalle béton | 110 | 110 | 2 | NULL | | | | | plafond avec ou sans remplissage | 110 | 110 | 1.45 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004686S | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1965 | | NULL | 2014-06-11 00:00:00 | NULL | NULL | NULL | 86 | NULL | NULL | NULL | | | D | B | 157.36 | 6.08 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0.29 | 3.02 | 2.43 | 1.6 | NULL | tout venant | 3.3 | NULL | 0.44 | 0 | [ "est", "nord", "ouest", "sud" ] | 0.07 | ITI | NULL | murs en briques creuses | NULL | 97.72 | 97.72 | 97.72 | 0.47 | | | | non isole | plancher lourd type entrevous terre-cuite, poutrelles béton | 48.06 | 48.06 | 0.35 | NULL | | | | ITI | plafond avec ou sans remplissage | 44.41 | 44.41 | 0.3 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004688U | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1975-1977 | 1975 | | NULL | 2014-06-11 00:00:00 | NULL | NULL | NULL | 85 | NULL | NULL | NULL | | | D | E | 163.61 | 38.29 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | collectif | | ecs solaire | | gaz | chaudiere gaz standard | | 1 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 3.37 | 7.56 | 0.33 | 1.22 | NULL | tout venant | 3 | NULL | 0.57 | 0 | [ "est", "nord", "ouest", "sud" ] | 0.149 | ITI | NULL | murs en blocs de béton creux | 20 | 71.38 | 71.38 | 71.38 | 1.11 | | | | ITE | plancher lourd type entrevous terre-cuite, poutrelles béton | 88.2 | 88.2 | 0.59 | NULL | | | | ITI | plafond avec ou sans remplissage | 88.2 | 88.2 | 0.83 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004689V | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1960 | | NULL | 2014-06-11 00:00:00 | NULL | NULL | NULL | 84 | NULL | NULL | NULL | | | C | C | 140 | 19 | individuel | electricite | pac air/air | | gaz | chaudiere gaz standard | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | bois | | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 6.71 | 6.71 | 0 | 0 | NULL | nord sud | 3 | 3.4 | 0.48 | 0 | [ "nord", "sud" ] | 0.32 | non isole | NULL | murs en béton banché | 30 | 38.68 | 28.58 | 38.68 | 2 | | | | non isole | dalle béton | 83 | 0 | 2 | NULL | | | | non isole | dalle béton | 83 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004690N | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2001-2005 | 2004 | | NULL | 2014-06-11 00:00:00 | NULL | NULL | NULL | 113 | NULL | NULL | NULL | | | C | A | 142.69 | 4.46 | individuel | electricite | pac air/air | | electricite | chaudiere electrique | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | argon ou krypton | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0.58 | 7.3 | 2.92 | 4.83 | NULL | tout venant | 1.8 | 2.2 | 0.39 | 0 | [ "est", "nord", "ouest", "sud" ] | 0.114 | ITI | NULL | murs en blocs de béton creux | 20 | 127.07 | 121.91 | 127.07 | 0.42 | | | | ITE | plancher à entrevous isolant | 68 | 68 | 0.45 | NULL | | | | ITI | plafond en plaque de plâtre | 68 | 68 | 0.19 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004691O | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1978-1982 | 1980 | | NULL | 2014-06-11 00:00:00 | NULL | NULL | NULL | 91 | NULL | NULL | NULL | | | D | B | 180.67 | 8.74 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | argon ou krypton | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 6.36 | 8.1 | 0.51 | 0 | NULL | tout venant | 1.9 | 2.2 | 0.39 | 0 | [ "nord", "ouest", "sud" ] | 0.16 | ITI | NULL | murs en briques creuses | 20 | 78.62 | 78.62 | 78.62 | 0.36 | | | | ITE | plancher à entrevous isolant | 92 | 92 | 0.45 | NULL | | | | ITI | plafond en plaque de plâtre | 92 | 92 | 0.2 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004692P | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1983-1988 | 1988 | | NULL | 2014-06-11 00:00:00 | NULL | NULL | NULL | 20 | NULL | NULL | NULL | | | E | C | 271 | 11 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | air sec | | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.7 | NULL | 0.46 | 0 | | 0.056 | non isole | NULL | | 0 | 34.51 | 18.77 | 34.51 | 0.89 | | | | ITI | dalle béton | 12 | 12 | 0.78 | NULL | | | | ITI | dalle béton | 12 | 12 | 0.34 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004693Q | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1992 | | NULL | 2014-06-11 00:00:00 | NULL | NULL | NULL | 91 | NULL | NULL | NULL | | | D | B | 215 | 10 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 2.56 | 3.8 | 1.06 | 1.36 | NULL | tout venant | 2.4 | 3 | 0.47 | 1 | [ "est", "nord", "ouest", "sud" ] | 0.069 | ITI | NULL | murs en blocs de béton creux | 20 | 130.44 | 118.81 | 130.44 | 0.44 | | | | ITE | plancher à entrevous isolant | 77.53 | 77.53 | 0.61 | NULL | | | | ITI | plafond bois sous solives bois | 86.46 | 86.46 | 0.2 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004694R | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1974 | | NULL | 2014-07-01 00:00:00 | NULL | NULL | NULL | 60 | NULL | NULL | NULL | | | D | E | 224 | 52 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.7 | 2.6 | 2.73 | 0 | | NULL | | NULL | murs en blocs de béton creux | NULL | 68 | 0 | 68 | NULL | | | | non isole | dalle béton | 60 | 60 | 2 | NULL | | | | | plafond en plaque de plâtre | 60 | 60 | 1.11 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004695 | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1974 | | NULL | 2014-06-11 00:00:00 | NULL | NULL | NULL | 133 | NULL | NULL | NULL | | | D | F | 187 | 56 | individuel | fioul | chaudiere fioul standard | | | | | 0 | NULL | NULL | | | | | | chaudiere fioul standard | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | simple vitrage | bois | air sec | | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 5.8 | 4.7 | 6.72 | 0 | | NULL | non isole | NULL | murs en blocs de béton creux | NULL | 160 | 0 | 160 | NULL | | | | non isole | dalle béton | 75 | 75 | 2 | NULL | | | | | combles aménagés sous rampant | 75 | 75 | 0.34 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004697 | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1974 | | NULL | 2014-06-11 00:00:00 | NULL | NULL | NULL | 160 | NULL | NULL | NULL | | | E | F | 240 | 58 | individuel | fioul | chaudiere fioul standard | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | simple vitrage | bois | | | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 5.8 | 4.7 | 2.02 | 0 | | NULL | non isole | NULL | murs en blocs de béton creux | NULL | 146 | 0 | 146 | NULL | | | | non isole | dalle béton | 160 | 160 | 2 | NULL | | | | | dalle béton | 127 | 127 | 0.34 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004702H | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1983-1988 | 1983 | | NULL | 2014-06-12 00:00:00 | NULL | NULL | NULL | 88 | NULL | NULL | NULL | | | D | B | 211 | 10 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 4.99 | 0 | 3.58 | NULL | tout venant | 2.4 | NULL | 0.44 | 1 | [ "est", "est ou ouest", "sud" ] | 0.186 | ITI | NULL | murs en blocs de béton creux | 20 | 79.64 | 67.64 | 79.64 | 0.38 | | | | ITE | plancher lourd type entrevous terre-cuite, poutrelles béton | 88 | 88 | 0.61 | NULL | | | | ITI | plafond bois sous solives bois | 88 | 88 | 0.24 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004703I | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1975-1977 | 1975 | | NULL | 2014-06-12 00:00:00 | NULL | NULL | NULL | 140 | NULL | NULL | NULL | | | D | A | 158.01 | 5.63 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 6.96 | 9.35 | 1.44 | 2.64 | NULL | tout venant | 3 | 3 | 0.5 | 0 | [ "est", "nord", "ouest", "sud" ] | NULL | ITI | NULL | murs en briques pleines doubles avec lame d'air | 20 | 113.45 | 0 | 113.45 | 1.11 | | | | ITE | dalle béton | 140 | 140 | 0.34 | NULL | | | | ITI | plafond en plaque de plâtre | 140 | 0 | 0.25 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004704J | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1974 | | NULL | 2014-06-12 00:00:00 | NULL | NULL | NULL | 56 | NULL | NULL | NULL | | | D | B | 172 | 7 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.7 | 2.6 | 3.86 | 0 | | NULL | ITI | NULL | murs en briques creuses | 33 | 47.76 | 0 | 47.76 | 0.98 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004706L | 13 | 0 | dpe arrêté 2012 facture logement | appartement | 1948-1974 | 1970 | | NULL | 2014-06-12 00:00:00 | NULL | NULL | NULL | 42 | NULL | NULL | NULL | | | N | N | 0 | 0 | | | chaudiere energie indetermine standard | | | | | 0 | NULL | NULL | | | | | | chaudiere energie indetermine standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | | NULL | | NULL | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004707M | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2001-2005 | 2005 | | NULL | 2014-06-12 00:00:00 | NULL | NULL | NULL | 85 | NULL | NULL | NULL | | | D | B | 197 | 9 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.7 | 2.6 | 3.08 | 0 | | NULL | ITI | NULL | murs en blocs de béton creux | 25 | 90.48 | 0 | 90.48 | 0.47 | | | | ITE | plancher lourd type entrevous terre-cuite, poutrelles béton | 50.5 | 50.5 | 0.43 | NULL | | | | | plafond en plaque de plâtre | 50 | 50 | 0.3 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004708N | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1978-1982 | 1978 | | NULL | 2014-06-12 00:00:00 | NULL | NULL | NULL | 120 | NULL | NULL | NULL | | | E | C | 284 | 17 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 11.2 | 5 | 2.4 | 2.1 | NULL | tout venant | 2.2 | 2.7 | 0.44 | 0 | [ "est", "nord", "ouest", "sud" ] | 0.153 | ITI | NULL | murs en blocs de béton creux | 20 | 114.3 | 114.3 | 114.3 | 1.11 | | | | ITE | dalle béton | 120 | 120 | 1 | NULL | | | | ITI | combles aménagés sous rampant | 120 | 120 | 0.18 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004710G | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1978-1982 | 1978 | | NULL | 2014-06-12 00:00:00 | NULL | NULL | NULL | 81 | NULL | NULL | NULL | | | D | B | 161 | 7 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « avant 1982 » | | double vitrage | métal sans rupture de pont thermique | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 10.06 | 6.8 | 0 | NULL | est ouest | 3.4 | NULL | 0.6 | 1 | [ "ouest", "sud" ] | 0.357 | ITI | NULL | murs en béton banché | 30 | 35.22 | 30.34 | 35.22 | 0.89 | | | | non isole | dalle béton | 81.41 | 0 | 2 | NULL | | | | non isole | dalle béton | 81.41 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004711 | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1974 | | NULL | 2014-06-12 00:00:00 | NULL | NULL | NULL | 72 | NULL | NULL | NULL | | | C | D | 131.81 | 30 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0 | 0 | 4.53 | 2.9 | NULL | est ouest | 2.7 | 2.7 | 0.46 | 0 | [ "est", "ouest" ] | NULL | non isole | NULL | murs en béton banché | 20 | 41.53 | 0 | 41.53 | 2 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004712I | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1974 | | NULL | 2014-06-12 00:00:00 | NULL | NULL | NULL | 72 | NULL | NULL | NULL | | | C | D | 131.81 | 30 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0 | 0 | 4.53 | 2.9 | NULL | est ouest | 2.7 | 2.7 | 0.46 | 0 | [ "est", "ouest" ] | NULL | non isole | NULL | murs en béton banché | 20 | 41.53 | 0 | 41.53 | 2 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004713J | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1974 | | NULL | 2014-06-12 00:00:00 | NULL | NULL | NULL | 39 | NULL | NULL | NULL | | | D | E | 191.59 | 43.81 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | | NULL | 0 | 0 | 0 | 16.04 | 0 | NULL | non traversant | 4.7 | 4.7 | 0.52 | 0 | [ "ouest" ] | NULL | non isole | NULL | murs en pan de bois sans remplissage tout venant | 8 | 15.82 | 0 | 15.82 | 2 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004714K | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1983-1988 | 1988 | | NULL | 2014-06-12 00:00:00 | NULL | NULL | NULL | 86 | NULL | NULL | NULL | | | C | A | 135.72 | 5.17 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 0 | 1.59 | 2.16 | NULL | est ouest | 2.9 | 2.9 | 0.44 | 0 | [ "est", "ouest" ] | NULL | ITI | NULL | murs en blocs de béton creux | 20 | 52.63 | 0 | 36.92 | 0.78 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004715 | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2014-06-12 00:00:00 | NULL | NULL | NULL | 38 | NULL | NULL | NULL | | | D | B | 199 | 8 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | | pvc | | | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | NULL | NULL | NULL | 0 | | NULL | | NULL | murs en béton banché | NULL | 15 | 0 | 15 | NULL | | | | | dalle béton | 38 | 38 | 0.59 | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004716M | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2010 | | NULL | 2014-06-12 00:00:00 | NULL | NULL | NULL | 41 | NULL | NULL | NULL | | | C | A | 127 | 5 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | métal avec rupture de pont thermique | air sec | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 0 | 0 | 6.61 | 0 | NULL | non traversant | 2.5 | 3.3 | 0.52 | 1 | [ "ouest" ] | 0.313 | ITI | NULL | murs en béton banché | 20 | 14.52 | 14.52 | 14.52 | 0.42 | | | | non isole | dalle béton | 41.43 | 0 | 2 | NULL | | | | non isole | dalle béton | 41.43 | 0 | 2.5 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004717N | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1972 | | NULL | 2014-06-12 00:00:00 | NULL | NULL | NULL | 60 | NULL | NULL | NULL | | | G | C | 495.22 | 13.92 | individuel | electricite | generateurs a effet joule | | bois | poele ou insert bois | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | simple vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 2.09 | 4.66 | 0 | 0 | NULL | nord sud | 4.7 | 4.7 | 0.52 | 0 | [ "nord", "sud" ] | NULL | ITE | NULL | murs en blocs de béton creux | 25 | 58.31 | 0 | 58.31 | 1.11 | | | | non isole | dalle béton | 60 | 60 | 2 | NULL | | | | ITI | plafond avec ou sans remplissage sous combles | 60 | 60 | 0.56 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004720H | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1975-1977 | 1975 | | NULL | 2014-06-12 00:00:00 | NULL | NULL | NULL | 91 | NULL | NULL | NULL | | | D | B | 163 | 7 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | métal sans rupture de pont thermique | air sec | | NULL | 0 | 7.5 | 14 | 0 | 0 | NULL | nord sud | 4.6 | NULL | 0.49 | 0 | [ "nord", "sud" ] | 0.455 | ITI | NULL | murs en béton banché | 20 | 25.8 | 25.8 | 25.8 | 1.11 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004721 | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1974 | | NULL | 2014-06-12 00:00:00 | NULL | NULL | NULL | 80 | NULL | NULL | NULL | | | E | C | 231.68 | 13.9 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs thermodynamique electrique(pac ou ballon) | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | argon ou krypton | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0 | 0 | 2.3 | 0 | NULL | non traversant | 2.6 | 2.6 | 0.46 | 0 | [ "est", "ouest" ] | NULL | non isole | NULL | murs en blocs de béton creux | 25 | 45.09 | 0 | 45.09 | 2 | | | | non isole | dalle béton | 40 | 40 | 0.37 | NULL | | | | ITI | plafond bois sous solives métalliques | 40 | 40 | 0.25 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004722J | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1974 | | NULL | 2014-06-12 00:00:00 | NULL | NULL | NULL | 69 | NULL | NULL | NULL | | | E | C | 270.9 | 14.4 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | simple vitrage | bois | argon ou krypton | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 7.59 | 1.69 | NULL | non traversant | 4.7 | 4.7 | 0.52 | 1 | [ "est", "ouest" ] | NULL | non isole | NULL | murs en blocs de béton pleins | 33 | 41 | 0 | 41 | 2 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004723K | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2001-2005 | 2005 | | NULL | 2014-06-12 00:00:00 | NULL | NULL | NULL | 43 | NULL | NULL | NULL | | | D | A | 164.08 | 5.77 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | argon ou krypton | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0 | 0 | 1.71 | 0 | NULL | non traversant | 2.6 | 2.6 | 0.46 | 1 | [ "ouest" ] | NULL | ITR | NULL | béton cellulaire | 27.5 | 21.7 | 0 | 21.7 | 0.42 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004725M | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1974 | | NULL | 2014-06-12 00:00:00 | NULL | NULL | NULL | 73 | NULL | NULL | NULL | | | E | C | 247 | 13 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.8 | 2.9 | 3.7 | 0 | | NULL | ITI | NULL | murs en briques creuses | 25 | 96.77 | 0 | 96.77 | 0.98 | | | | ITI | dalle béton | 73.17 | 73.17 | 0.37 | NULL | | | | | plafond avec ou sans remplissage sous combles | 73.17 | 73.17 | 0.34 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004727O | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1989-2000 | 1989 | | NULL | 2014-06-12 00:00:00 | NULL | NULL | NULL | 80 | NULL | NULL | NULL | | | D | B | 176 | 7 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | air sec | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 1.7 | 0 | 6.6 | 3.54 | NULL | tout venant | 2.4 | 3 | 0.51 | 1 | [ "est", "nord", "ouest" ] | 0.398 | ITI | NULL | murs en béton banché | 20 | 85.61 | 17.91 | 20.01 | 0.5 | | | | ITE | dalle béton | 80.46 | 80.46 | 0.67 | NULL | | | | non isole | dalle béton | 80.46 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004728P | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1974 | | NULL | 2014-06-13 00:00:00 | NULL | NULL | NULL | 20 | NULL | NULL | NULL | | | E | C | 321.25 | 18.17 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs thermodynamique electrique(pac ou ballon) | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 1.62 | 3.24 | NULL | est ouest | 3.5 | 4.7 | 0.52 | 0 | [ "est", "ouest" ] | NULL | ITI | NULL | murs en pierre de taille et moellons avec remplissage tout venant | NULL | 38.81 | 0 | 12.21 | 2 | | | | non isole | | 20 | 0 | 2 | NULL | | | | ITI | bardeaux et remplissage | 20 | 0 | NULL | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004729Q | 13 | 0 | dpe arrêté 2012 facture logement | appartement | 1948-1974 | 1965 | | NULL | 2014-06-13 00:00:00 | NULL | NULL | NULL | 39 | NULL | NULL | NULL | | | N | N | 0 | 0 | | | chaudiere energie indetermine standard | | | | | 0 | NULL | NULL | | | | | | chaudiere energie indetermine standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | | NULL | | NULL | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1004736O | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2006-2012 | 2006 | | NULL | 2014-06-13 00:00:00 | NULL | NULL | NULL | 176 | NULL | NULL | NULL | | | D | B | 196.6 | 10.53 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | métal avec rupture de pont thermique | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 3.87 | 23.08 | 27.92 | 4.74 | NULL | tout venant | 3.4 | 3.4 | 0.56 | 1 | [ "est", "nord", "ouest", "sud" ] | NULL | ITI | NULL | murs en blocs de béton creux | 25 | 289.04 | 0 | 289.04 | 0.4 | | | | non isole | dalle béton | 131 | 131 | 2 | NULL | | | | ITI | dalle béton | 130 | 130 | 0.27 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |