| 1413V1002090F | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1983-1988 | 1983 | | NULL | 2014-03-18 00:00:00 | NULL | NULL | NULL | 39 | NULL | NULL | NULL | | | D | B | 211 | 8 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | métal sans rupture de pont thermique | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 9 | 0 | 0 | NULL | non traversant | 3.3 | NULL | 0.54 | 1 | [ "sud" ] | 0.514 | ITI | NULL | murs en béton banché | 20 | 51.6 | 8.5 | 29.1 | 0.78 | | | | ITE | | 39 | 39 | 0.78 | NULL | | | | non isole | dalle béton | 39 | 0 | 2.5 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002091G | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1978-1982 | 1978 | | NULL | 2014-03-18 00:00:00 | NULL | NULL | NULL | 68 | NULL | NULL | NULL | | | C | D | 143 | 33 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | simple vitrage | bois | | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 4.48 | 7.88 | 0 | 0 | NULL | nord sud | 4 | 4.7 | 0.52 | 1 | [ "nord", "sud" ] | 0.231 | non isole | NULL | murs en blocs de béton creux | 20 | 91 | 41.14 | 58.75 | 2 | | | | non isole | dalle béton | 68.3 | 0 | 2 | NULL | | | | non isole | dalle béton | 68.3 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002092H | 13 | 0 | dpe arrêté 2012 facture logement | appartement | 2001-2005 | 2005 | | NULL | 2014-03-18 00:00:00 | NULL | NULL | NULL | 51 | NULL | NULL | NULL | | | N | N | 0 | 0 | | | | | | | | 0 | NULL | NULL | | | | | | chaudiere bois | | gaz | chaudiere gaz standard | | 0 | NULL | NULL | 0 | | | | pvc | | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | | NULL | murs en béton banché | NULL | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002093I | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1975-1977 | 1977 | | NULL | 2014-03-18 00:00:00 | NULL | NULL | NULL | 73 | NULL | NULL | NULL | | | D | C | 227 | 12 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.7 | 2.6 | 3.15 | 0 | | NULL | ITI | NULL | murs en briques creuses | 20 | 62.9 | 0 | 62.9 | 1.11 | | | | ITI | dalle béton | 72.99 | 72.99 | 0.35 | NULL | | | | | plafond en plaque de plâtre | 72.99 | 72.99 | 0.34 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002094J | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2014-03-18 00:00:00 | NULL | NULL | NULL | 74 | NULL | NULL | NULL | | | D | E | 179 | 42 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 4.02 | 0 | 4.02 | 0 | NULL | est ouest | 3.5 | 4.7 | 0.52 | 0 | [ "nord", "ouest" ] | 0.09 | non isole | NULL | | 0 | 102.09 | 81.28 | 102.09 | 2 | | | | non isole | dalle béton | 74.01 | 0 | 2 | NULL | | | | non isole | dalle béton | 74.01 | 0 | 2.5 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002095K | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2014-03-18 00:00:00 | NULL | NULL | NULL | 54 | NULL | NULL | NULL | | | E | E | 275 | 52 | individuel | fioul | chaudiere fioul standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere fioul standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | argon ou krypton | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 0 | 0 | 11.08 | 11.08 | NULL | est ouest | 2.1 | 2.6 | 0.44 | 1 | [ "est", "ouest" ] | 0.739 | non isole | NULL | | 0 | 71.04 | 7.84 | 25.04 | 2 | | | | non isole | dalle béton | 53.82 | 0 | 2 | NULL | | | | non isole | dalle béton | 53.82 | 0 | 2.5 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002096L | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2014-03-18 00:00:00 | NULL | NULL | NULL | 78 | NULL | NULL | NULL | | | C | A | 146 | 5 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 9 | 2.11 | NULL | non traversant | 1.8 | 2.2 | 0.38 | 0 | [ "est", "ouest" ] | 0.122 | ITI | NULL | murs en blocs de béton creux | 20 | 117.3 | 79.85 | 95.85 | 0.4 | | | | ITE | dalle béton | 39 | 39 | 0.27 | NULL | | | | ITI | plafond bois sous solives bois | 39 | 39 | 0.14 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002098N | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1967 | | NULL | 2014-03-19 00:00:00 | NULL | NULL | NULL | 51 | NULL | NULL | NULL | | | C | D | 143.29 | 33.53 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | gaz | chaudiere gaz standard | | 1 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | simple vitrage | bois | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0 | 10 | 0 | 0 | NULL | non traversant | 3.6 | 4.5 | 0.48 | 1 | [ "sud" ] | 0.392 | non isole | NULL | murs en blocs de béton pleins | 30 | 22.05 | 15.5 | 22.05 | 2 | | | | | dalle béton | NULL | NULL | NULL | NULL | | | | | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002099O | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1989-2000 | 1989 | | NULL | 2014-03-19 00:00:00 | NULL | NULL | NULL | 87 | NULL | NULL | NULL | | | C | A | 115 | 4 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | métal avec rupture de pont thermique | air sec | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 5.1 | 9.3 | 0 | 0 | NULL | nord sud | 2.3 | 2.8 | 0.48 | 1 | [ "nord", "sud" ] | 0.298 | ITI | NULL | murs en béton banché | 20 | 36.46 | 33.85 | 36.46 | 0.43 | | | | non isole | dalle béton | 86.9 | 0 | 2 | NULL | | | | non isole | dalle béton | 86.9 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002100X | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1970 | | NULL | 2014-03-19 00:00:00 | NULL | NULL | NULL | 75 | NULL | NULL | NULL | | | D | B | 156.48 | 6.4 | individuel | electricite | pac air/air | | electricite | chaudiere electrique | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 4.12 | 7.34 | 0 | 0 | NULL | nord sud | 1.8 | 2.2 | 0.38 | 0 | [ "nord", "sud" ] | 0.259 | ITI | NULL | murs en blocs de béton creux | 20 | 44.44 | 32.85 | 44.44 | 2 | | | | non isole | dalle béton | 36.8 | 36.8 | 0.32 | NULL | | | | ITI | combles aménagés sous rampant | 45 | 45 | 0.25 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002102@ | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1983-1988 | 1983 | | NULL | 2014-03-19 00:00:00 | NULL | NULL | NULL | 42 | NULL | NULL | NULL | | | F | D | 415 | 23 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0.25 | 3.65 | 1.25 | 0 | NULL | tout venant | 2.5 | 3.2 | 0.47 | 0 | [ "nord", "ouest", "sud" ] | 0.156 | ITI | NULL | murs en blocs de béton creux | 23 | 42.85 | 27.85 | 42.85 | 0.78 | | | | ITE | plancher à entrevous isolant | 41.5 | 41.5 | 0.61 | NULL | | | | non isole | dalle béton | 41.5 | 41.5 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002104 | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1989-2000 | 1989 | | NULL | 2014-03-19 00:00:00 | NULL | NULL | NULL | 32 | NULL | NULL | NULL | | | E | C | 321.96 | 16.43 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 1.68 | 2.28 | 1.72 | 0 | NULL | tout venant | 3.5 | 4.7 | 0.52 | 1 | [ "nord", "ouest", "sud" ] | 0.115 | ITI | NULL | murs en blocs de béton creux | 20 | 54.31 | 43.91 | 54.31 | 0.5 | | | | | | NULL | NULL | NULL | NULL | | | | ITI | plafond lourd type entrevous terre-cuite, poutrelles béton | 32.4 | 32.4 | 0.3 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002108F | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2014-03-19 00:00:00 | NULL | NULL | NULL | 54 | NULL | NULL | NULL | | | D | E | 229 | 40 | individuel | gaz | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | simple vitrage | bois | | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0 | 0 | 0 | 5 | NULL | non traversant | 3.7 | 4.7 | 0.52 | 0 | [ "est", "ouest" ] | 0.179 | non isole | NULL | murs en béton banché | 20 | 43 | 23 | 41 | 2 | | | | non isole | dalle béton | 54.21 | 54.21 | 2 | NULL | | | | non isole | dalle béton | 54.21 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002109G | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1955 | | NULL | 2014-03-19 00:00:00 | NULL | NULL | NULL | 56 | NULL | NULL | NULL | | | D | E | 193.6 | 45.3 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | gaz | chaudiere gaz standard | | 1 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | argon ou krypton | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 1.23 | 0 | 7.29 | 2.48 | NULL | tout venant | 2.4 | NULL | 0.44 | 1 | [ "est", "nord", "ouest" ] | 0.374 | non isole | NULL | murs en blocs de béton pleins | 40 | 30.34 | 18.43 | 30.34 | 2 | | | | | dalle béton | NULL | NULL | NULL | NULL | | | | | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002110Y | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2011 | | NULL | 2014-03-19 00:00:00 | NULL | NULL | NULL | 54 | NULL | NULL | NULL | | | D | B | 203.2 | 9.57 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Extracteur mécanique sur conduit non modifié de ventilation naturelle existante | | double vitrage | métal sans rupture de pont thermique | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 8.9 | 0 | 0 | NULL | non traversant | 3.1 | 4.1 | 0.54 | 0 | [ "sud" ] | 0.129 | ITI | NULL | murs en blocs de béton creux | 20 | 60.18 | 60.18 | 60.18 | 0.4 | | | | non isole | dalle béton | 20 | 20 | 2 | NULL | | | | ITI | plafond avec ou sans remplissage | 54.4 | 54.4 | 0.27 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002111@ | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2014-03-19 00:00:00 | NULL | NULL | NULL | 110 | NULL | NULL | NULL | | | E | C | 258 | 14 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0 | 9.32 | 1.69 | 0.9 | NULL | non traversant | 2.2 | 2.6 | 0.46 | 0 | [ "est", "ouest", "sud" ] | 0.101 | ITI | NULL | murs en blocs de béton creux | 20 | 106.19 | 106.19 | 106.19 | 0.62 | | | | non isole | dalle béton | 110 | 110 | 0.35 | NULL | | | | ITI | combles aménagés sous rampant | 110 | 110 | 0.61 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002113 | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1978-1982 | 1978 | | NULL | 2014-03-19 00:00:00 | NULL | NULL | NULL | 125 | NULL | NULL | NULL | | | E | C | 268 | 15 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.7 | 2.6 | 4.2 | 0 | | 0.295 | ITI | NULL | murs en blocs de béton creux | 20 | 130.39 | 30.5 | 130.39 | 0.62 | | | | non isole | plancher lourd type entrevous terre-cuite, poutrelles béton | 124.53 | 124.53 | 2 | NULL | | | | ITI | plafond lourd type entrevous terre-cuite, poutrelles béton | 124.53 | 124.53 | 0.47 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002114 | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1978-1982 | 1978 | | NULL | 2014-03-19 00:00:00 | NULL | NULL | NULL | 125 | NULL | NULL | NULL | | | E | C | 268 | 15 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.7 | 2.6 | 4.2 | 0 | | 0.295 | ITI | NULL | murs en blocs de béton creux | 20 | 130.39 | 30.5 | 130.39 | 0.62 | | | | non isole | plancher lourd type entrevous terre-cuite, poutrelles béton | 124.53 | 124.53 | 2 | NULL | | | | ITI | plafond lourd type entrevous terre-cuite, poutrelles béton | 124.53 | 124.53 | 0.47 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002115D | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2014-03-19 00:00:00 | NULL | NULL | NULL | 77 | NULL | NULL | NULL | | | D | E | 185 | 43 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | métal sans rupture de pont thermique | | | NULL | 0 | 0 | 0 | 10 | 7.5 | NULL | est ouest | 6.2 | NULL | 0.55 | 0 | [ "est", "ouest" ] | 0.456 | ITI | NULL | murs en béton banché | 25 | 20.9 | 20.9 | 20.9 | 2 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002116E | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2007 | | NULL | 2014-03-19 00:00:00 | NULL | NULL | NULL | 66 | NULL | NULL | NULL | | | C | A | 146.94 | 5.44 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 3.28 | 3.28 | 0 | 0 | NULL | nord sud | 2.6 | 2.6 | 0.44 | 0 | [ "nord", "sud" ] | 0.181 | ITI | NULL | murs en blocs de béton pleins | 30 | 83.68 | 29.75 | 83.68 | 0.4 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002119H | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1978-1982 | 1978 | | NULL | 2014-03-19 00:00:00 | NULL | NULL | NULL | 137 | NULL | NULL | NULL | | | D | F | 196 | 58 | individuel | fioul | chaudiere fioul standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere fioul standard | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « avant 1982 » | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 2.71 | 7.66 | 7.81 | 1.55 | NULL | tout venant | 2.5 | 3 | 0.47 | 1 | [ "est", "nord", "ouest", "sud" ] | 0.156 | ITI | NULL | | 0 | 168.08 | 106.88 | 168.08 | 1.11 | | | | ITE | dalle béton | 114.61 | 114.61 | 1 | NULL | | | | ITE | dalle béton | 114.61 | 114.61 | 0.56 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002120@ | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2014-03-19 00:00:00 | NULL | NULL | NULL | 60 | NULL | NULL | NULL | | | D | B | 163 | 7 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | bois | | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 0 | 0 | 3.81 | NULL | non traversant | 2.7 | 3.1 | 0.47 | 1 | [ "est" ] | 0.166 | ITI | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 40 | 34.08 | 19.11 | 26.49 | 0.4 | | | | ITE | dalle béton | 60 | 60 | 0.37 | NULL | | | | non isole | plafond lourd type entrevous terre-cuite, poutrelles béton | 60 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002122B | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2014-03-20 00:00:00 | NULL | NULL | NULL | 83 | NULL | NULL | NULL | | | E | C | 270 | 14 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | bois | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0.9 | 6.56 | 0 | 0 | NULL | non traversant | 2.8 | 2.8 | 0.47 | 0 | [ "nord", "sud" ] | 0.114 | ITI | NULL | | 0 | 78.39 | 57.99 | 78.39 | 2 | | | | non isole | dalle béton | 72 | 72 | 0.34 | NULL | | | | non isole | plafond avec ou sans remplissage sous combles | 70.1 | 70.1 | 2.5 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002123C | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2014-03-20 00:00:00 | NULL | NULL | NULL | 100 | NULL | NULL | NULL | | | C | A | 104 | 3 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | argon ou krypton | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.6 | 2.6 | 3.32 | 0 | | 0.098 | non isole | NULL | murs en blocs de béton creux | 20 | 53.53 | 27.5 | 53.53 | 0.35 | | | | ITE | dalle béton | 45 | 45 | 0.27 | NULL | | | | | combles aménagés sous rampant | 50 | 50 | 0.13 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002124D | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2014-03-20 00:00:00 | NULL | NULL | NULL | 65 | NULL | NULL | NULL | | | C | A | 108 | 3 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | | pvc | | | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en blocs de béton creux | 20 | 59.8 | 0 | 59.8 | 0.35 | | | | ITE | dalle béton | 55 | 55 | 0.35 | NULL | | | | | combles aménagés sous rampant | 15 | 15 | 0.13 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002126F | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1983-1988 | 1983 | | NULL | 2014-03-20 00:00:00 | NULL | NULL | NULL | 65 | NULL | NULL | NULL | | | D | B | 202 | 10 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | métal sans rupture de pont thermique | | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 0 | 2.3 | 0 | 6.8 | NULL | 90° | 3.5 | NULL | 0.49 | 1 | [ "est", "sud" ] | 0.164 | ITI | NULL | | 0 | 46.4 | 46.4 | 46.4 | 0.78 | | | | | plancher lourd type entrevous terre-cuite, poutrelles béton | 65 | 0 | 0.78 | NULL | | | | non isole | plafond lourd type entrevous terre-cuite, poutrelles béton | 65 | 0 | 2.5 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002128H | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2006-2012 | 2006 | | NULL | 2014-03-20 00:00:00 | NULL | NULL | NULL | 102 | NULL | NULL | NULL | | | D | B | 184.16 | 9.26 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | métal sans rupture de pont thermique | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 0 | 6.52 | 2.08 | NULL | non traversant | 4.1 | 4.1 | 0.54 | 0 | [ "est", "ouest" ] | 0.279 | ITI | NULL | murs en blocs de béton creux | 20 | 87.66 | 22.25 | 87.66 | 0.4 | | | | ITE | plancher à entrevous isolant | 97.9 | 97.9 | 0.36 | NULL | | | | ITI | plafond en plaque de plâtre | 97.9 | 97.9 | 0.25 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002129I | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2014-03-20 00:00:00 | NULL | NULL | NULL | 51 | NULL | NULL | NULL | | | D | E | 174 | 40 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | métal sans rupture de pont thermique | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0 | 0 | 0 | 9.1 | NULL | non traversant | 3.4 | NULL | 0.49 | 1 | [ "est" ] | 0.303 | non isole | NULL | murs en briques creuses | 0 | 26.9 | 20.9 | 26.9 | 2 | | | | non isole | dalle béton | 51.38 | 0 | 2 | NULL | | | | non isole | dalle béton | 51.38 | 0 | 2.5 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002130A | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1989 | | NULL | 2014-03-20 00:00:00 | NULL | NULL | NULL | 162 | NULL | NULL | NULL | | | D | C | 219 | 12 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | métal avec rupture de pont thermique | air sec | | NULL | 0 | 3.5 | 15.8 | 2.6 | 0 | NULL | tout venant | 3.5 | 3.5 | 0.48 | 0 | [ "nord", "ouest", "sud" ] | 0.151 | ITI | NULL | murs en blocs de béton creux | 20 | 122.9 | 122.9 | 122.9 | 0.5 | | | | non isole | plancher lourd type entrevous terre-cuite, poutrelles béton | 161 | 161 | 2 | NULL | | | | ITI | plafond bois sous solives bois | 161.2 | 161.2 | 0.3 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002131B | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1978-1982 | 1978 | | NULL | 2014-03-20 00:00:00 | NULL | NULL | NULL | 125 | NULL | NULL | NULL | | | D | B | 200 | 10 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 1.8 | 8.5 | 0 | 3.25 | NULL | tout venant | 2.1 | 2.6 | 0.44 | 0 | [ "est", "nord", "sud" ] | 0.104 | ITI | NULL | murs en blocs de béton creux | 23 | 134.2 | 116.95 | 134.2 | 0.78 | | | | non isole | plancher lourd type entrevous terre-cuite, poutrelles béton | 86 | 86 | 0.37 | NULL | | | | ITI | plafond bois sous solives bois | 86 | 86 | 0.33 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002132C | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1974 | | NULL | 2014-03-20 00:00:00 | NULL | NULL | NULL | 75 | NULL | NULL | NULL | | | D | C | 223.51 | 11.34 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0.86 | 1.36 | 0 | 0 | NULL | nord sud | 2.8 | 2.8 | 0.44 | 1 | [ "nord", "sud" ] | NULL | non isole | NULL | murs en blocs de béton pleins | 28 | 41.61 | 0 | 41.61 | 2 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002135F | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1970 | | NULL | 2014-03-20 00:00:00 | NULL | NULL | NULL | 40 | NULL | NULL | NULL | | | E | C | 272.88 | 12.63 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0.7 | 0 | 0.9 | 0.65 | NULL | tout venant | 2.3 | 2.6 | 0.46 | 0 | [ "est", "indetermine", "nord", "ouest" ] | 0.092 | ITI | NULL | murs en blocs de béton creux | 20 | 56.9 | 47.04 | 56.9 | 0.62 | | | | non isole | dalle béton | 39.5 | 39.5 | 0.37 | NULL | | | | ITI | plafond bois sous solives bois | 39.5 | 39.5 | 0.1 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002137H | 13 | 0 | dpe arrêté 2012 facture logement | appartement | avant 1948 | 1930 | | NULL | 2014-03-20 00:00:00 | NULL | NULL | NULL | 76 | NULL | NULL | NULL | | | N | N | 0 | 0 | | | chaudiere energie indetermine condensation | | | | | 0 | NULL | NULL | | | | | | chaudiere energie indetermine condensation | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | | NULL | | NULL | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002140B | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1983-1988 | 1984 | | NULL | 2014-03-20 00:00:00 | NULL | NULL | NULL | 82 | NULL | NULL | NULL | | | D | B | 151.06 | 6.59 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 0 | 6.72 | 3.9 | NULL | est ouest | 2.2 | 2.7 | 0.4 | 1 | [ "est", "ouest" ] | 0.283 | ITI | NULL | murs en blocs de béton creux | 20 | 48.12 | 26.87 | 48.12 | 0.78 | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002142D | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1983-1988 | 1984 | | NULL | 2014-03-20 00:00:00 | NULL | NULL | NULL | 69 | NULL | NULL | NULL | | | D | B | 161.24 | 7.1 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 0 | 6.48 | 2.52 | NULL | est ouest | 2.7 | 2.7 | 0.4 | 1 | [ "est", "ouest" ] | 0.327 | ITI | NULL | murs en blocs de béton creux | 20 | 36.5 | 18.5 | 36.5 | 0.78 | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002143E | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2014-03-20 00:00:00 | NULL | NULL | NULL | 94 | NULL | NULL | NULL | | | D | D | 188 | 35 | individuel | electricite | pac air/air | | gaz | chaudiere gaz standard | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 5.06 | 3.84 | 0 | 0 | NULL | nord sud | 3.5 | 2.6 | 0.44 | 0 | [ "nord", "sud" ] | 0.097 | ITI | NULL | murs en blocs de béton creux | 20 | 123.76 | 82.45 | 108.16 | 0.98 | | | | non isole | dalle béton | 93.19 | 93.19 | 2 | NULL | | | | ITI | plafond entre solives bois avec ou sans remplissage | 75.19 | 75.19 | 0.17 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002144F | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2014-03-20 00:00:00 | NULL | NULL | NULL | 140 | NULL | NULL | NULL | | | C | B | 145 | 6 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 3.25 | 15.76 | 1.54 | 0 | NULL | non traversant | 2.1 | 2.6 | 0.44 | 0 | [ "nord", "ouest", "sud" ] | 0.111 | ITI | NULL | murs en briques pleines doubles avec lame d'air | 30 | 164.51 | 164.51 | 164.51 | 0.62 | | | | ITE | dalle béton | 100 | 100 | 0.59 | NULL | | | | ITE | plafond bois sur solives bois | 100 | 100 | 0.4 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002147I | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1975-1977 | 1975 | | NULL | 2014-03-20 00:00:00 | NULL | NULL | NULL | 240 | NULL | NULL | NULL | | | E | C | 273 | 13 | individuel | electricite | generateurs a effet joule | | bois | poele ou insert bois | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 3.96 | 8.1 | 19.22 | 15.6 | NULL | tout venant | 2.4 | 3.1 | 0.47 | 1 | [ "est", "nord", "ouest", "sud" ] | 0.18 | non isole | NULL | murs en briques pleines doubles avec lame d'air | 30 | 213.07 | 213.07 | 213.07 | 1.65 | | | | ITE | dalle béton | 120.09 | 120.09 | 1 | NULL | | | | ITE | dalle béton | 151.91 | 151.91 | 0.56 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002148J | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2014-03-20 00:00:00 | NULL | NULL | NULL | 65 | NULL | NULL | NULL | | | D | C | 159 | 16 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 3.61 | 8.9 | 0 | 0 | NULL | nord sud | 4 | 4.7 | 0.52 | 0 | [ "nord", "sud" ] | 0.331 | non isole | NULL | murs en briques pleines doubles avec lame d'air | 30 | 82.64 | 25.31 | 37.54 | 1.65 | | | | non isole | dalle béton | 64.54 | 0 | 2 | NULL | | | | non isole | dalle béton | 64.54 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002149K | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1989 | | NULL | 2014-03-20 00:00:00 | NULL | NULL | NULL | 56 | NULL | NULL | NULL | | | D | B | 223 | 10 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 2.69 | 1.59 | 0 | 3.91 | NULL | tout venant | 2.4 | 3.1 | 0.47 | 0 | [ "est", "nord", "sud" ] | 0.319 | ITI | NULL | murs en blocs de béton creux | 20 | 31.24 | 17.49 | 17.49 | 0.5 | | | | ITE | dalle béton | 55.99 | 55.99 | 0.61 | NULL | | | | ITI | plafond bois sur solives bois | 55.99 | 55.99 | 0.3 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002151D | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1956 | | NULL | 2014-03-20 00:00:00 | NULL | NULL | NULL | 124 | NULL | NULL | NULL | | | E | F | 296 | 69 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 2.01 | 1.82 | 3.36 | 8.77 | NULL | tout venant | 3.5 | 4.7 | 0.52 | 0 | [ "est", "nord", "ouest", "sud" ] | 0.111 | non isole | NULL | murs en briques pleines doubles avec lame d'air | 30 | 149.66 | 127.35 | 149.66 | 1.65 | | | | non isole | dalle béton | 123.6 | 123.6 | 2 | NULL | | | | ITI | plafond bois sous solives bois | 123.6 | 100.9 | 0.59 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002152E | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2014-03-20 00:00:00 | NULL | NULL | NULL | 57 | NULL | NULL | NULL | | | D | D | 186 | 30 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | simple vitrage | bois | | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 8.43 | 0 | 0 | 3.2 | NULL | 90° | 4 | 4.7 | 0.52 | 0 | [ "est", "nord" ] | 0.244 | ITI | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 20 | 82.57 | 35.97 | 55.57 | 2 | | | | non isole | plancher avec ou sans remplissage | 57.01 | 0 | 1.45 | NULL | | | | non isole | plafond avec ou sans remplissage | 57.01 | 0 | 1.45 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002153F | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1983-1988 | 1984 | | NULL | 2014-03-20 00:00:00 | NULL | NULL | NULL | 71 | NULL | NULL | NULL | | | E | C | 248.25 | 12.57 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 0 | 6.48 | 2.52 | NULL | est ouest | 2.7 | 2.7 | 0.4 | 1 | [ "est", "ouest" ] | 0.157 | ITI | NULL | murs en blocs de béton creux | 20 | 66.5 | 48.5 | 66.5 | 0.78 | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | 69 | 69 | 0.44 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002154G | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2014-03-20 00:00:00 | NULL | NULL | NULL | 46 | NULL | NULL | NULL | | | E | C | 248 | 12 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0.52 | 4.96 | 0 | 1.34 | NULL | tout venant | 2.4 | 2.6 | 0.44 | 0 | [ "est", "nord", "sud" ] | 0.179 | non isole | NULL | murs en béton banché | 28 | 34.69 | 31.18 | 34.69 | 2 | | | | non isole | dalle béton | 45.9 | 0 | 2 | NULL | | | | non isole | dalle béton | 45.9 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002155H | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1983-1988 | 1984 | | NULL | 2014-03-20 00:00:00 | NULL | NULL | NULL | 69 | NULL | NULL | NULL | | | D | B | 198.87 | 9.73 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 0 | 6.48 | 2.52 | NULL | est ouest | 2.7 | 2.7 | 0.4 | 1 | [ "est", "ouest" ] | 0.327 | ITI | NULL | murs en blocs de béton creux | 20 | 36.5 | 18.5 | 36.5 | 0.78 | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | 69 | 69 | 0.44 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002157J | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1983-1988 | 1984 | | NULL | 2014-03-20 00:00:00 | NULL | NULL | NULL | 69 | NULL | NULL | NULL | | | D | B | 217.99 | 10.5 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 0 | 6.48 | 2.52 | NULL | est ouest | 2.7 | 2.7 | 0.4 | 1 | [ "est", "ouest" ] | 0.291 | ITI | NULL | murs en blocs de béton creux | 20 | 46.88 | 21.88 | 46.88 | 0.78 | | | | ITI | dalle béton | 69 | 69 | 0.61 | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002159L | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1983-1988 | 1984 | | NULL | 2014-03-20 00:00:00 | NULL | NULL | NULL | 58 | NULL | NULL | NULL | | | E | C | 273.4 | 14.47 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 0 | 3.15 | 4.62 | NULL | est ouest | 2.5 | 2.7 | 0.4 | 0 | [ "est", "ouest" ] | 0.148 | ITI | NULL | murs en blocs de béton creux | 20 | 70.23 | 44.73 | 70.23 | 0.78 | | | | ITI | dalle béton | 58 | 58 | 0.61 | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002160D | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1983-1988 | 1985 | | NULL | 2014-03-20 00:00:00 | NULL | NULL | NULL | 165 | NULL | NULL | NULL | | | E | C | 249.8 | 12.23 | individuel | electricite | generateurs a effet joule | | bois | poele ou insert bois | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 13.68 | 1.52 | 8.08 | NULL | tout venant | 2.4 | 3 | 0.47 | 0 | [ "est", "ouest", "sud" ] | 0.105 | ITI | NULL | murs en blocs de béton creux | 20 | 198.42 | 198.42 | 198.42 | 0.78 | | | | non isole | plancher lourd type entrevous terre-cuite, poutrelles béton | 85.88 | 85.88 | 2 | NULL | | | | ITI | combles aménagés sous rampant | 85.88 | 85.88 | 0.33 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002162F | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1983-1988 | 1984 | | NULL | 2014-03-20 00:00:00 | NULL | NULL | NULL | 69 | NULL | NULL | NULL | | | D | B | 177.93 | 8.27 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 0 | 6.48 | 2.52 | NULL | est ouest | 2.7 | 2.7 | 0.4 | 1 | [ "est", "ouest" ] | 0.226 | ITI | NULL | murs en blocs de béton creux | 20 | 48.75 | 30.75 | 48.75 | 0.78 | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1002164H | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1983-1988 | 1984 | | NULL | 2014-03-20 00:00:00 | NULL | NULL | NULL | 71 | NULL | NULL | NULL | | | E | C | 231.02 | 11.36 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 0 | 6.48 | 2.52 | NULL | est ouest | 2.7 | 2.7 | 0.4 | 1 | [ "est", "ouest" ] | 0.18 | ITI | NULL | murs en blocs de béton creux | 20 | 59 | 41 | 59 | 0.78 | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | 69 | 69 | 0.44 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |