| 1413V1000431C | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1978-1982 | 1980 | | NULL | 2014-01-23 00:00:00 | NULL | NULL | NULL | 82 | NULL | NULL | NULL | | | C | D | 142.51 | 33.35 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | gaz | chaudiere gaz standard | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « avant 1982 » | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0.8 | 9.66 | 3.85 | 1.8 | NULL | tout venant | 2.6 | 3.2 | 0.43 | 0 | [ "est", "nord", "ouest", "sud" ] | 0.311 | ITI | NULL | murs en blocs de béton creux | 20 | 86.54 | 35.76 | 86.54 | 0.89 | | | | non isole | dalle béton | 82.8 | 82.8 | 0.35 | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000433E | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1975-1977 | 1975 | | NULL | 2014-01-23 00:00:00 | NULL | NULL | NULL | 85 | NULL | NULL | NULL | | | C | A | 134 | 4 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | métal avec rupture de pont thermique | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 9.06 | 13.14 | 0 | 0 | NULL | nord sud | 2.7 | 3.4 | 0.52 | 0 | [ "nord", "sud" ] | 0.389 | ITI | NULL | murs en béton banché | 20 | 121.91 | 34.91 | 49.91 | 0.98 | | | | non isole | | 42.5 | 42.5 | 0.37 | NULL | | | | ITI | plafond bois sous solives bois | 42.5 | 42.5 | 0.56 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000434F | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1983-1988 | 1988 | | NULL | 2014-01-23 00:00:00 | NULL | NULL | NULL | 96 | NULL | NULL | NULL | | | D | C | 205 | 11 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | métal avec rupture de pont thermique | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.9 | 3.6 | 5.48 | 0 | | NULL | non isole | NULL | murs en béton banché | 20 | 73.01 | 0 | 73.01 | 0.78 | | | | | dalle béton | 95.54 | 95.54 | 0.61 | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000435G | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2001-2005 | 2005 | | NULL | 2014-01-23 00:00:00 | NULL | NULL | NULL | 115 | NULL | NULL | NULL | | | C | A | 116 | 4 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.7 | 2.6 | 2.29 | 0 | | NULL | non isole | NULL | murs en blocs de béton creux | 20 | 140.03 | 0 | 140.03 | 0.47 | | | | | dalle béton | 43.5 | 43.5 | 0.43 | NULL | | | | | plafond entre solives bois avec ou sans remplissage | 45 | 45 | 0.3 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000437I | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 2000 | | NULL | 2014-01-23 00:00:00 | NULL | NULL | NULL | 98 | NULL | NULL | NULL | | | C | D | 106 | 23 | individuel | gaz | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | | | | | | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | bois | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 3.3 | 3.2 | 3.73 | 0 | | NULL | ITI | NULL | murs en blocs de béton creux | 20 | 94.46 | 0 | 94.46 | 0.35 | | | | non isole | dalle béton | 98 | 98 | 0.35 | NULL | | | | | plafond en plaque de plâtre | 98 | 98 | 0.24 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000439K | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1952 | | NULL | 2014-01-23 00:00:00 | NULL | NULL | NULL | 67 | NULL | NULL | NULL | | | E | C | 245.14 | 17.35 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0 | 0 | 5.85 | 6.34 | NULL | est ouest | 2.7 | 2.7 | 0.44 | 1 | [ "est", "ouest" ] | NULL | non isole | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 40 | 42.61 | 0 | 42.61 | 2 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000440C | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1983-1988 | 1983 | | NULL | 2014-01-23 00:00:00 | NULL | NULL | NULL | 83 | NULL | NULL | NULL | | | E | C | 312 | 17 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « avant 1982 » | | double vitrage | métal avec rupture de pont thermique | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 5.1 | 10 | 0 | 2.3 | NULL | tout venant | 2.6 | 3.2 | 0.56 | 1 | [ "est", "nord", "sud" ] | 0.261 | ITI | NULL | murs en béton banché | 22.5 | 61.15 | 49.15 | 61.15 | 0.78 | | | | non isole | dalle béton | 83.05 | 83.05 | 2 | NULL | | | | non isole | dalle béton | 83.05 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000442 | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2014-01-23 00:00:00 | NULL | NULL | NULL | 47 | NULL | NULL | NULL | | | D | B | 206 | 9 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 4 | 0 | 0.95 | 2.5 | NULL | tout venant | 2.2 | 2.6 | 0.46 | 1 | [ "est", "nord", "ouest" ] | 0.287 | ITI | NULL | murs en béton banché | 22.5 | 26.55 | 18.55 | 26.55 | 0.4 | | | | non isole | dalle béton | 46.6 | 0 | 2 | NULL | | | | non isole | dalle béton | 46.6 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000443F | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2014-01-23 00:00:00 | NULL | NULL | NULL | 63 | NULL | NULL | NULL | | | E | F | 273 | 64 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | métal sans rupture de pont thermique | air sec | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 12.94 | 0 | 3.79 | 0 | NULL | non traversant | 3.1 | NULL | 0.54 | 0 | [ "nord", "ouest" ] | 0.372 | non isole | NULL | murs en blocs de béton creux | 20 | 28.69 | 28.27 | 28.69 | 2 | | | | non isole | dalle béton | 63.49 | 0 | 2 | NULL | | | | non isole | dalle béton | 63.49 | 63.49 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000446I | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1978-1982 | 1978 | | NULL | 2014-01-23 00:00:00 | NULL | NULL | NULL | 85 | NULL | NULL | NULL | | | C | E | 149 | 43 | individuel | fioul | chaudiere fioul standard | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | chaudiere fioul standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 0 | 0 | 4.47 | 6.02 | NULL | est ouest | 2.2 | 2.7 | 0.44 | 0 | [ "est", "ouest" ] | 0.092 | ITI | NULL | murs en blocs de béton creux | 20 | 123.86 | 103.86 | 123.86 | 0.89 | | | | ITE | | 50 | 50 | 0.37 | NULL | | | | ITI | plafond bois sous solives bois | 50 | 50 | 0.25 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000449 | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1960 | | NULL | 2014-01-24 00:00:00 | NULL | NULL | NULL | 65 | NULL | NULL | NULL | | | D | E | 214.3 | 50.14 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 10.28 | 3.54 | 0 | 0 | NULL | nord sud | 1.4 | 1.4 | 0.5 | 1 | [ "nord", "sud" ] | NULL | non isole | NULL | murs en béton banché | 20 | 51.3 | 0 | 51.3 | 2 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000450D | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1960 | | NULL | 2014-01-24 00:00:00 | NULL | NULL | NULL | 65 | NULL | NULL | NULL | | | D | E | 214.3 | 50.14 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 10.28 | 3.54 | 0 | 0 | NULL | nord sud | 1.4 | 1.4 | 0.5 | 1 | [ "nord", "sud" ] | NULL | non isole | NULL | murs en béton banché | 20 | 51.3 | 0 | 51.3 | 2 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000454 | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1972 | | NULL | 2014-01-24 00:00:00 | NULL | NULL | NULL | 77 | NULL | NULL | NULL | | | E | E | 285.69 | 55.25 | individuel | electricite | pac air/eau | | gaz | chaudiere gaz standard | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 5.28 | 8.04 | 1.92 | 0 | NULL | tout venant | 2.2 | 2.6 | 0.4 | 0 | [ "nord", "ouest", "sud" ] | NULL | ITI | NULL | murs en blocs de béton creux | NULL | 72.5 | 0 | 72.5 | 2 | | | | non isole | dalle béton | 77 | 77 | 2 | NULL | | | | ITI | dalle béton | 77 | 77 | 0.66 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000455I | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1972 | | NULL | 2014-01-24 00:00:00 | NULL | NULL | NULL | 77 | NULL | NULL | NULL | | | E | E | 285.69 | 55.25 | individuel | electricite | pac air/eau | | gaz | chaudiere gaz standard | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 5.28 | 8.04 | 1.92 | 0 | NULL | tout venant | 2.2 | 2.6 | 0.4 | 0 | [ "nord", "ouest", "sud" ] | NULL | ITI | NULL | murs en blocs de béton creux | NULL | 72.5 | 0 | 72.5 | 2 | | | | non isole | dalle béton | 77 | 77 | 2 | NULL | | | | ITI | dalle béton | 77 | 77 | 0.66 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000456J | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1975-1977 | 1975 | | NULL | 2014-01-24 00:00:00 | NULL | NULL | NULL | 25 | NULL | NULL | NULL | | | D | B | 226 | 9 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | métal sans rupture de pont thermique | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0.48 | 4.69 | 0 | 0 | NULL | non traversant | 3.3 | NULL | 0.54 | 1 | [ "nord", "sud" ] | 0.285 | ITI | NULL | murs en béton banché | 20 | 41.94 | 12.94 | 12.94 | 0.98 | | | | | dalle béton | 24.88 | 0 | 1 | NULL | | | | non isole | dalle béton | 24.88 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000457K | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1998 | | NULL | 2014-01-24 00:00:00 | NULL | NULL | NULL | 112 | NULL | NULL | NULL | | | D | C | 165.29 | 11.55 | individuel | electricite | pac air/air | | gaz | chaudiere gaz standard | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 4.72 | 4.82 | 1.3 | 1.84 | NULL | tout venant | 2.2 | NULL | 0.47 | 0 | [ "est", "nord", "ouest", "sud" ] | 0.125 | ITI | NULL | murs en blocs de béton creux | 20 | 107.39 | 88.75 | 107.39 | 0.35 | | | | ITE | dalle béton | 112 | 112 | 0.61 | NULL | | | | ITI | plafond bois sous solives bois | 112 | 112 | 0.3 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000458L | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1989-2000 | 2000 | | NULL | 2014-01-24 00:00:00 | NULL | NULL | NULL | 91 | NULL | NULL | NULL | | | B | C | 70.51 | 15.7 | individuel | gaz | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 2.88 | 9.03 | 0 | 0 | NULL | non traversant | 2.7 | 2.7 | 0.46 | 1 | [ "nord", "sud" ] | NULL | ITI | NULL | murs en béton banché | 20 | 52.29 | 0 | 34.91 | 0.35 | | | | | | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | 90.73 | 25.58 | 0.19 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000459M | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1972 | | NULL | 2014-01-24 00:00:00 | NULL | NULL | NULL | 150 | NULL | NULL | NULL | | | E | F | 262 | 61 | individuel | gaz | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 9.19 | 8.08 | 0 | 6.21 | NULL | tout venant | 3.4 | 4.7 | 0.52 | 0 | [ "est", "est ou ouest", "nord", "sud" ] | 0.151 | ITI | NULL | murs en blocs de béton pleins | 33 | 154.05 | 154.05 | 154.05 | 2 | | | | non isole | dalle béton | 150 | 150 | 2 | NULL | | | | non isole | dalle béton | 140 | 140 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000460 | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2001-2005 | 2004 | | NULL | 2014-01-24 00:00:00 | NULL | NULL | NULL | 136 | NULL | NULL | NULL | | | C | D | 92.36 | 30.43 | individuel | electricite | pac air/eau | | fioul | chaudiere fioul standard | | 0 | NULL | NULL | | | | individuel | | chaudiere fioul standard | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | solaire photovoltaïque | double vitrage | pvc | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 1.77 | 13.09 | 5.82 | NULL | tout venant | 2.4 | 2.6 | 0.44 | 0 | [ "est", "ouest", "sud" ] | NULL | ITI | NULL | murs en blocs de béton creux | NULL | 147.29 | 0 | 147.29 | 0.46 | | | | ITE | dalle béton | 92 | 92 | 0.26 | NULL | | | | ITI | | 92 | 92 | 0.15 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000461F | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2001-2005 | 2004 | | NULL | 2014-01-24 00:00:00 | NULL | NULL | NULL | 136 | NULL | NULL | NULL | | | C | D | 92.36 | 30.43 | individuel | electricite | pac air/eau | | fioul | chaudiere fioul standard | | 0 | NULL | NULL | | | | individuel | | chaudiere fioul standard | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | solaire photovoltaïque | double vitrage | pvc | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 1.77 | 13.09 | 5.82 | NULL | tout venant | 2.4 | 2.6 | 0.44 | 0 | [ "est", "ouest", "sud" ] | NULL | ITI | NULL | murs en blocs de béton creux | NULL | 147.29 | 0 | 147.29 | 0.46 | | | | ITE | dalle béton | 92 | 92 | 0.26 | NULL | | | | ITI | | 92 | 92 | 0.15 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000462 | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1950 | | NULL | 2014-01-24 00:00:00 | NULL | NULL | NULL | 64 | NULL | NULL | NULL | | | F | D | 449.86 | 26.62 | individuel | electricite | chaudiere electrique | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | métal sans rupture de pont thermique | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 0 | 0 | 7.8 | NULL | non traversant | 4.7 | 4.7 | 0.52 | 1 | [ "est" ] | NULL | non isole | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 55 | 49 | 0 | 38.5 | 1.9 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000463H | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1950 | | NULL | 2014-01-24 00:00:00 | NULL | NULL | NULL | 64 | NULL | NULL | NULL | | | F | D | 449.86 | 26.62 | individuel | electricite | chaudiere electrique | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | métal sans rupture de pont thermique | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 0 | 0 | 7.8 | NULL | non traversant | 4.7 | 4.7 | 0.52 | 1 | [ "est" ] | NULL | non isole | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 55 | 49 | 0 | 38.5 | 1.9 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000466K | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1960 | | NULL | 2014-01-24 00:00:00 | NULL | NULL | NULL | 22 | NULL | NULL | NULL | | | F | C | 365.74 | 18.27 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | simple vitrage | bois | | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 0 | 0 | 3.2 | NULL | non traversant | 4.7 | 4.7 | 0.52 | 0 | [ "est" ] | NULL | non isole | NULL | murs en blocs de béton pleins | 30 | 14.8 | 0 | 6.3 | 2 | | | | non isole | dalle béton | 22 | 0 | 2 | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000467L | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1983-1988 | 1987 | | NULL | 2014-01-24 00:00:00 | NULL | NULL | NULL | 105 | NULL | NULL | NULL | | | E | C | 288.34 | 16.45 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0 | 0 | 6.02 | 7.88 | NULL | est ouest | 2.4 | NULL | 0.43 | 1 | [ "est", "ouest" ] | 0.108 | ITI | NULL | murs en blocs de béton creux | 20 | 139.86 | 114.66 | 139.86 | 0.78 | | | | non isole | dalle béton | 96 | 96 | 0.34 | NULL | | | | ITI | combles aménagés sous rampant | 96 | 96 | 0.33 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000468M | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1978-1982 | 1980 | | NULL | 2014-01-24 00:00:00 | NULL | NULL | NULL | 83 | NULL | NULL | NULL | | | E | D | 287 | 26 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 4.54 | 6.98 | 3.54 | 0 | NULL | tout venant | 3.5 | 4.7 | 0.56 | 0 | [ "nord", "ouest", "sud" ] | 0.17 | non isole | NULL | murs en blocs de béton creux | 25 | 125.78 | 73.55 | 82.78 | 2 | | | | non isole | plancher lourd type entrevous terre-cuite, poutrelles béton | 46.27 | 46.27 | 2 | NULL | | | | non isole | plafond avec ou sans remplissage sous combles | 55 | 55 | 2.5 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000469N | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2001-2005 | 2004 | | NULL | 2014-01-24 00:00:00 | NULL | NULL | NULL | 97 | NULL | NULL | NULL | | | B | C | 78 | 15 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 2.49 | 6.52 | 3.75 | 0 | NULL | tout venant | 2.1 | 2.6 | 0.4 | 0 | [ "nord", "ouest", "sud" ] | 0.109 | ITI | NULL | murs en blocs de béton creux | 20 | 104.49 | 104.49 | 104.49 | 0.47 | | | | ITE | plancher lourd type entrevous terre-cuite, poutrelles béton | 97 | 97 | 0.36 | NULL | | | | ITI | plafond bois sous solives bois | 97 | 97 | 0.3 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000471G | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1950 | | NULL | 2014-01-24 00:00:00 | NULL | NULL | NULL | 53 | NULL | NULL | NULL | | | D | B | 206.52 | 9.56 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 7.49 | 1.6 | 0 | 0 | NULL | non traversant | 2.3 | 2.6 | 0.46 | 0 | [ "nord", "sud" ] | 0.307 | ITI | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 60 | 28.61 | 20.56 | 28.61 | 0.98 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000472H | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1989 | | NULL | 2014-01-24 00:00:00 | NULL | NULL | NULL | 89 | NULL | NULL | NULL | | | C | D | 99 | 29 | individuel | fioul | chaudiere fioul standard | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | fioul | chaudiere fioul standard | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 1.73 | 5.42 | 2.5 | 5.9 | NULL | tout venant | 2.6 | 3.2 | 0.47 | 0 | [ "est", "nord", "ouest", "sud" ] | 0.269 | ITI | NULL | murs en blocs de béton creux | 25 | 52.23 | 42.23 | 52.23 | 0.5 | | | | ITE | dalle béton | 45 | 45 | 0.67 | NULL | | | | ITI | plafond avec ou sans remplissage sous combles | 45 | 45 | 0.3 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000473I | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1950 | | NULL | 2014-01-24 00:00:00 | NULL | NULL | NULL | 59 | NULL | NULL | NULL | | | D | B | 168.37 | 7.38 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 5.8 | 6.3 | 0 | 0 | NULL | nord sud | 2.3 | 2.6 | 0.46 | 0 | [ "nord", "sud" ] | 0.408 | ITI | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 60 | 31.48 | 17.55 | 31.48 | 0.98 | | | | | | NULL | NULL | NULL | NULL | | | | | plafond entre solives bois avec ou sans remplissage | 58.5 | 58.5 | 0.25 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000474J | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2001-2005 | 2004 | | NULL | 2014-01-24 00:00:00 | NULL | NULL | NULL | 57 | NULL | NULL | NULL | | | D | B | 159.41 | 6.04 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 3.22 | 0 | 7.51 | 0 | NULL | est ouest | 2.6 | 2.6 | 0.46 | 1 | [ "nord", "ouest" ] | NULL | ITI | NULL | murs en béton banché | 20 | 32.5 | 0 | 26.52 | 0.54 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000477M | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2014-01-24 00:00:00 | NULL | NULL | NULL | 51 | NULL | NULL | NULL | | | F | D | 390 | 22 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 3.28 | 5.93 | 0 | 0 | NULL | nord sud | 3.7 | 4.8 | 0.56 | 1 | [ "nord", "sud" ] | 0.343 | non isole | NULL | murs en béton banché | 30 | 34.43 | 17.64 | 34.43 | 1.3 | | | | non isole | plancher lourd type entrevous terre-cuite, poutrelles béton | 51 | 51 | 2 | NULL | | | | non isole | dalle béton | 51 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000478N | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1975-1977 | 1975 | | NULL | 2014-01-24 00:00:00 | NULL | NULL | NULL | 118 | NULL | NULL | NULL | | | D | D | 178 | 31 | individuel | gaz | chaudiere gaz standard | | bois | poele ou insert bois | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | argon ou krypton | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 4.63 | 8.65 | 0 | 2.49 | NULL | tout venant | 3.5 | 4.8 | 0.44 | 1 | [ "est", "nord", "sud" ] | 0.122 | ITI | NULL | murs en béton banché | 20 | 136.4 | 113.72 | 136.4 | 1.11 | | | | ITE | dalle béton | 72.45 | 72.45 | 0.37 | NULL | | | | ITE | combles aménagés sous rampant | 71.66 | 71.66 | 0.56 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000480 | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1974 | | NULL | 2014-01-24 00:00:00 | NULL | NULL | NULL | 66 | NULL | NULL | NULL | | | E | C | 250.37 | 12.44 | individuel | electricite | pac air/eau | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | simple vitrage | bois | | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 0 | 4.46 | 13.92 | NULL | non traversant | 4.1 | 4.8 | 0.56 | 0 | [ "est", "ouest" ] | NULL | non isole | NULL | murs en blocs de béton creux | NULL | 66.5 | 0 | 56.77 | 2 | | | | non isole | dalle béton | 0 | 0 | NULL | NULL | | | | non isole | dalle béton | 65.8 | 65.8 | 2 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000481H | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1974 | | NULL | 2014-01-24 00:00:00 | NULL | NULL | NULL | 66 | NULL | NULL | NULL | | | E | C | 250.37 | 12.44 | individuel | electricite | pac air/eau | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | simple vitrage | bois | | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 0 | 4.46 | 13.92 | NULL | non traversant | 4.1 | 4.8 | 0.56 | 0 | [ "est", "ouest" ] | NULL | non isole | NULL | murs en blocs de béton creux | NULL | 66.5 | 0 | 56.77 | 2 | | | | non isole | dalle béton | 0 | 0 | NULL | NULL | | | | non isole | dalle béton | 65.8 | 65.8 | 2 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000483J | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1960 | | NULL | 2014-01-24 00:00:00 | NULL | NULL | NULL | 118 | NULL | NULL | NULL | | | D | D | 157.17 | 33.96 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | electricite | pac air/air | | | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 1.65 | 12.87 | 7.17 | 4.25 | NULL | tout venant | 2.4 | 2.8 | 0.44 | 0 | [ "est", "nord", "ouest", "sud" ] | 0.231 | ITI | NULL | murs en blocs de béton creux | 20 | 86.42 | 86.42 | 86.42 | 2 | | | | non isole | dalle béton | 118 | 118 | 2 | NULL | | | | ITI | plafond en plaque de plâtre | 118 | 118 | 0.19 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000487N | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1989 | | NULL | 2014-01-24 00:00:00 | NULL | NULL | NULL | 90 | NULL | NULL | NULL | | | C | B | 122 | 6 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Extracteur mécanique sur conduit non modifié de ventilation naturelle existante | | double vitrage | pvc | | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0 | 9.2 | 4.18 | 7.98 | NULL | tout venant | 1.9 | 2.2 | 0.38 | 0 | [ "est", "ouest", "sud" ] | 0.276 | ITI | NULL | murs en blocs de béton creux | 20 | 56.09 | 56.09 | 56.09 | 0.5 | | | | ITE | dalle béton | 90 | 90 | 0.61 | NULL | | | | non isole | dalle béton | 90 | 25 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000488O | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2014-01-24 00:00:00 | NULL | NULL | NULL | 51 | NULL | NULL | NULL | | | F | D | 357 | 21 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 0.4 | 6.87 | 3.48 | NULL | tout venant | 4 | 4.7 | 0.52 | 0 | [ "est", "ouest", "sud" ] | 0.2 | non isole | NULL | murs en blocs de béton creux | 20 | 54.46 | 43.13 | 54.46 | 2 | | | | non isole | dalle béton | 51 | 0 | 2 | NULL | | | | non isole | dalle béton | 51 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000489P | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1989 | | NULL | 2014-01-24 00:00:00 | NULL | NULL | NULL | 200 | NULL | NULL | NULL | | | D | B | 171.62 | 9.24 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 7.07 | 14.24 | 0.45 | 3.2 | NULL | tout venant | 3.2 | 3.2 | 0.47 | 1 | [ "est", "nord", "ouest", "sud" ] | NULL | ITI | NULL | murs en blocs de béton creux | 20 | 178.31 | 0 | 178.31 | 0.5 | | | | ITI | dalle béton | 102.18 | 102.18 | 0.61 | NULL | | | | ITI | plafond en plaque de plâtre | 102.18 | 102.18 | 0.13 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000490H | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2001-2005 | 2005 | | NULL | 2014-01-24 00:00:00 | NULL | NULL | NULL | 67 | NULL | NULL | NULL | | | C | B | 148 | 6 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.7 | 2.6 | 2.38 | 0 | | NULL | ITI | NULL | murs en blocs de béton pleins | 20 | 47.89 | 0 | 47.89 | 0.35 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000492J | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1975-1977 | 1977 | | NULL | 2014-01-25 00:00:00 | NULL | NULL | NULL | 109 | NULL | NULL | NULL | | | E | E | 258 | 43 | individuel | gaz | chaudiere gaz basse temperature | | bois | poele ou insert bois | | 0 | NULL | NULL | | | | | | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | simple vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 5.8 | 4.7 | 1.5 | 0 | | 0.069 | non isole | NULL | murs en blocs de béton pleins | 33 | 159.93 | 69 | 159.93 | 2 | | | | ITI | dalle béton | 62.5 | 62.5 | 1 | NULL | | | | non isole | dalle béton | 47 | 47 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000493K | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2014-01-25 00:00:00 | NULL | NULL | NULL | 45 | NULL | NULL | NULL | | | E | C | 289 | 15 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 1.4 | 6 | NULL | non traversant | 3.4 | 4.7 | 0.52 | 0 | [ "est", "ouest" ] | 0.239 | non isole | NULL | murs en pierre de taille et moellons avec remplissage tout venant | 50 | 77 | 23.6 | 35.4 | 1.9 | | | | non isole | plancher entre solives bois avec ou sans remplissage | 44.72 | 0 | 1.1 | NULL | | | | non isole | plafond entre solives bois avec ou sans remplissage | 44.72 | 0 | 1.2 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000494L | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2014-01-25 00:00:00 | NULL | NULL | NULL | 109 | NULL | NULL | NULL | | | E | C | 233 | 12 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | métal sans rupture de pont thermique | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 3.94 | 26.86 | 0 | 0 | NULL | non traversant | 4.6 | NULL | 0.58 | 0 | [ "nord", "sud" ] | 0.2 | ITI | NULL | murs en briques pleines doubles avec lame d'air | 30 | 122.89 | 122.89 | 122.89 | 2 | | | | non isole | dalle béton | 52.97 | 52.97 | 2 | NULL | | | | ITI | bardeaux et remplissage | 55.92 | 55.92 | 0.39 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000496N | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2014-01-25 00:00:00 | NULL | NULL | NULL | 103 | NULL | NULL | NULL | | | C | A | 106 | 3 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 6 | 8 | 0 | 0 | NULL | nord sud | 2.1 | 2.6 | 0.44 | 0 | [ "nord", "sud" ] | 0.28 | ITI | NULL | | 0 | 94 | 36 | 44 | 0.4 | | | | non isole | dalle béton | 102 | 0 | 2 | NULL | | | | non isole | dalle béton | 102 | 0 | 2.5 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000497O | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2014-01-25 00:00:00 | NULL | NULL | NULL | 76 | NULL | NULL | NULL | | | E | E | 246 | 41 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | simple vitrage | bois | | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 0 | 7.28 | 3.04 | NULL | est ouest | 4 | 4.7 | 0.52 | 0 | [ "est", "ouest" ] | 0.249 | non isole | NULL | murs en blocs de béton creux | 20 | 45.48 | 31.11 | 45.48 | 2 | | | | non isole | dalle béton | 40.1 | 40.1 | 0.37 | NULL | | | | non isole | plafond bois sous solives bois | 42.2 | 42.2 | 2.3 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000498P | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1978-1982 | 1978 | | NULL | 2014-01-25 00:00:00 | NULL | NULL | NULL | 255 | NULL | NULL | NULL | | | D | E | 163 | 39 | individuel | fioul | chaudiere fioul standard | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | bois | air sec | | NULL | 0 | 8 | 5 | 17 | 5.5 | NULL | tout venant | 3.1 | 3.1 | 0.47 | 0 | [ "est", "nord", "ouest", "sud" ] | 0.144 | ITI | NULL | murs en blocs de béton creux | 20 | 211.5 | 211.5 | 211.5 | 0.89 | | | | non isole | plancher lourd type entrevous terre-cuite, poutrelles béton | 134 | 134 | 2 | NULL | | | | ITI | plafond bois sous solives bois | 134 | 134 | 0.44 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000502B | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2014-01-26 00:00:00 | NULL | NULL | NULL | 49 | NULL | NULL | NULL | | | E | F | 255 | 59 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 3.36 | 3.36 | NULL | est ouest | 3.4 | 4.7 | 0.52 | 0 | [ "est", "ouest" ] | 0.269 | non isole | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 55 | 115.24 | 18.27 | 40.13 | 1.9 | | | | non isole | plancher avec ou sans remplissage | 49.14 | 0 | 1.45 | NULL | | | | non isole | plafond avec ou sans remplissage | 49.14 | 0 | 1.45 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000503C | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1983-1988 | 1983 | | NULL | 2014-01-26 00:00:00 | NULL | NULL | NULL | 63 | NULL | NULL | NULL | | | D | B | 167 | 8 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | métal sans rupture de pont thermique | | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 0 | 7.17 | 2.43 | NULL | est ouest | 3.3 | NULL | 0.57 | 0 | [ "est", "ouest" ] | 0.267 | ITI | NULL | murs en béton banché | 28 | 51.91 | 26.29 | 51.91 | 0.78 | | | | ITE | dalle béton | 62.79 | 62.79 | 0.78 | NULL | | | | non isole | dalle béton | 62.79 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000504D | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2006-2012 | 2006 | | NULL | 2014-01-26 00:00:00 | NULL | NULL | NULL | 95 | NULL | NULL | NULL | | | B | A | 74 | 2 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | bois | | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0.57 | 17.87 | 0 | 0.67 | NULL | non traversant | 2.1 | 2.4 | 0.43 | 0 | [ "est", "nord", "sud" ] | NULL | non isole | NULL | murs en pan de bois sans remplissage tout venant | 8 | 75.11 | 0 | 75.11 | 0.11 | | | | isole | dalle béton | 95 | 95 | 0.12 | NULL | | | | ITI | | 94.43 | 94.43 | 0.1 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000505E | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1978-1982 | 1978 | | NULL | 2014-01-26 00:00:00 | NULL | NULL | NULL | 38 | NULL | NULL | NULL | | | E | C | 275 | 15 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0.98 | 5.55 | 0 | 0.28 | NULL | non traversant | 3.5 | 4.8 | 0.56 | 0 | [ "est", "nord", "sud" ] | 0.095 | ITI | NULL | murs en pan de bois sans remplissage tout venant | 8 | 64.71 | 64.71 | 64.71 | 0.89 | | | | non isole | dalle béton | 38.49 | 0 | 2 | NULL | | | | ITI | combles aménagés sous rampant | 50.03 | 50.03 | 0.44 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000508H | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2014-01-26 00:00:00 | NULL | NULL | NULL | 182 | NULL | NULL | NULL | | | D | F | 187 | 56 | individuel | fioul | chaudiere fioul standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere fioul standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | bois | air sec | | NULL | 0 | 10.5 | 9 | 2.4 | 3 | NULL | tout venant | 4.7 | 4.7 | 0.52 | 0 | [ "est", "nord", "ouest", "sud" ] | 0.11 | non isole | NULL | murs en blocs de béton creux | 20 | 201.1 | 201.1 | 201.1 | 2 | | | | non isole | | 70 | 70 | 0.37 | NULL | | | | ITI | plafond bois sous solives bois | 100 | 100 | 0.41 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |