| 1413V1000177J | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2014-01-13 00:00:00 | NULL | NULL | NULL | 90 | NULL | NULL | NULL | | | G | D | 546 | 35 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 3 | 9.22 | 1.88 | 1.88 | NULL | tout venant | 2.3 | 2.8 | 0.47 | 1 | [ "est", "nord", "ouest", "sud" ] | 0.158 | non isole | NULL | murs en blocs de béton creux | 25 | 85.29 | 85.29 | 85.29 | 2 | | | | non isole | dalle béton | 90 | 90 | 2 | NULL | | | | non isole | dalle béton | 90 | 90 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000178K | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1983-1988 | 1983 | | NULL | 2014-01-13 00:00:00 | NULL | NULL | NULL | 181 | NULL | NULL | NULL | | | D | B | 175 | 9 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | métal sans rupture de pont thermique | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 10.22 | 1.34 | 10.38 | 1.34 | NULL | tout venant | 3.3 | NULL | 0.57 | 0 | [ "est", "nord", "ouest", "sud" ] | 0.094 | ITI | NULL | murs en blocs de béton creux | 20 | 224.22 | 224.22 | 224.22 | 0.78 | | | | | dalle béton | 93 | 93 | 0.37 | NULL | | | | ITI | plafond bois sur solives bois | 93 | 93 | 0.33 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000180D | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2006-2012 | 2006 | | NULL | 2014-01-13 00:00:00 | NULL | NULL | NULL | 358 | NULL | NULL | NULL | | | B | A | 68 | 3 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | métal avec rupture de pont thermique | | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 6.41 | 6.5 | 16.59 | 3.6 | NULL | tout venant | 2.6 | 3.2 | 0.56 | 0 | [ "est", "nord", "ouest", "sud" ] | 0.124 | ITI | NULL | murs en blocs de béton creux | 20 | 350.79 | 233.78 | 350.79 | 0.35 | | | | ITI | dalle béton | 158 | 158 | 0.27 | NULL | | | | ITI | plafond bois sous solives bois | 130 | 130 | 0.1 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000182F | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1989-2000 | 1989 | | NULL | 2014-01-13 00:00:00 | NULL | NULL | NULL | 20 | NULL | NULL | NULL | | | C | A | 141 | 5 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | métal avec rupture de pont thermique | air sec | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 0 | 4.13 | 0 | 0 | NULL | non traversant | 2.6 | 3.4 | 0.52 | 1 | [ "sud" ] | 0.59 | ITI | NULL | murs en béton banché | 20 | 7.87 | 2.87 | 7.87 | 0.5 | | | | | | 19.98 | 0 | 0.67 | NULL | | | | | | 19.98 | 0 | 0.39 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000183G | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2014-01-13 00:00:00 | NULL | NULL | NULL | 84 | NULL | NULL | NULL | | | C | A | 134 | 5 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | métal avec rupture de pont thermique | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 3.7 | 7.43 | 0 | 0 | NULL | nord sud | 3.1 | 3.8 | 0.52 | 0 | [ "nord", "sud" ] | 0.263 | ITI | NULL | murs en blocs de béton creux | 20 | 37.7 | 31.17 | 37.7 | 2 | | | | non isole | dalle béton | 83.5 | 0 | 2 | NULL | | | | non isole | dalle béton | 83.8 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000184H | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1960 | | NULL | 2014-01-13 00:00:00 | NULL | NULL | NULL | 48 | NULL | NULL | NULL | | | D | E | 217.17 | 42.51 | individuel | electricite | pac air/air | | gaz | chaudiere gaz standard | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | simple vitrage | bois | | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 0 | 16.32 | 16.32 | NULL | est ouest | 1.4 | 1.4 | 0.56 | 0 | [ "est", "ouest" ] | NULL | non isole | NULL | murs en béton banché | 20 | 38.43 | 0 | 38.43 | 2 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000186J | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2014-01-14 00:00:00 | NULL | NULL | NULL | 84 | NULL | NULL | NULL | | | C | A | 146 | 5 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | métal avec rupture de pont thermique | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 3.7 | 7.43 | 0 | 0 | NULL | nord sud | 3.1 | 3.8 | 0.52 | 1 | [ "nord", "sud" ] | 0.291 | ITI | NULL | murs en blocs de béton creux | 20 | 33.7 | 27.17 | 33.7 | 2 | | | | non isole | dalle béton | 83.5 | 0 | 2 | NULL | | | | non isole | dalle béton | 83.8 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000188L | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1972 | | NULL | 2014-01-14 00:00:00 | NULL | NULL | NULL | 15 | NULL | NULL | NULL | | | D | B | 159.44 | 7.47 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ecs thermodynamique electrique(pac ou ballon) | | 1 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | bois | air sec | | NULL | 0 | 0 | 0 | 3.99 | 0 | NULL | non traversant | 3.2 | 3.2 | 0.47 | 0 | [ "ouest" ] | 0.575 | ITI | NULL | murs en béton banché | 30 | 7.89 | 2.95 | 7.89 | 0.98 | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000189M | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2001-2005 | 2001 | | NULL | 2014-01-14 00:00:00 | NULL | NULL | NULL | 74 | NULL | NULL | NULL | | | C | A | 134 | 4 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | métal avec rupture de pont thermique | | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0 | 9.3 | 0 | 2.1 | NULL | non traversant | 2.7 | 3.2 | 0.52 | 1 | [ "est", "sud" ] | 0.207 | ITI | NULL | murs en béton banché | 20 | 43.8 | 43.6 | 43.8 | 0.47 | | | | non isole | dalle béton | 73.5 | 0 | 2 | NULL | | | | non isole | dalle béton | 73.5 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000192G | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2014-01-14 00:00:00 | NULL | NULL | NULL | 78 | NULL | NULL | NULL | | | C | A | 126 | 5 | individuel | electricite | pac air/eau | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | | NULL | 0 | 6.07 | 4.6 | 0 | 0 | NULL | nord sud | 2.6 | 2.6 | 0.44 | 0 | [ "nord", "sud" ] | 0.237 | ITR | NULL | murs en blocs de béton pleins | 30 | 50.27 | 34.27 | 34.27 | 0.4 | | | | ITE | dalle béton | 77.82 | 77.82 | 0.37 | NULL | | | | ITI | dalle béton | 77.82 | 0 | 0.25 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000193 | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2014-01-14 00:00:00 | NULL | NULL | NULL | 78 | NULL | NULL | NULL | | | C | A | 126 | 5 | individuel | electricite | pac air/eau | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | | NULL | 0 | 6.07 | 4.6 | 0 | 0 | NULL | nord sud | 2.6 | 2.6 | 0.44 | 0 | [ "nord", "sud" ] | 0.237 | ITR | NULL | murs en blocs de béton pleins | 30 | 50.27 | 34.27 | 34.27 | 0.4 | | | | ITE | dalle béton | 77.82 | 77.82 | 0.37 | NULL | | | | ITI | dalle béton | 77.82 | 0 | 0.25 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000195J | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1964 | | NULL | 2014-01-14 00:00:00 | NULL | NULL | NULL | 84 | NULL | NULL | NULL | | | C | D | 131.61 | 28.54 | individuel | gaz | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ecs solaire | | gaz | chaudiere gaz basse temperature | | 1 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | argon ou krypton | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 2.42 | 7.13 | 3.22 | NULL | tout venant | 1.9 | 2.2 | 0.35 | 1 | [ "est", "ouest", "sud" ] | 0.173 | ITR | NULL | murs en béton banché | 20 | 76.48 | 60.84 | 76.48 | 0.63 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000197L | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2001-2005 | 2005 | | NULL | 2014-01-14 00:00:00 | NULL | NULL | NULL | 42 | NULL | NULL | NULL | | | D | A | 153 | 5 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.7 | 2.6 | 3.3 | 0 | | NULL | non isole | NULL | murs en béton banché | 20 | 30.02 | 0 | 30.02 | 0.47 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000198M | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2013-2021 | 2013 | | NULL | 2014-01-14 00:00:00 | NULL | NULL | NULL | 46 | NULL | NULL | NULL | | | D | B | 195 | 8 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « avant 1982 » | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 6.48 | 0 | 0 | 0 | NULL | non traversant | 2.4 | 2.9 | 0.48 | 1 | [ "nord" ] | 0.372 | ITI | NULL | murs en béton banché | 20 | 12.81 | 10.96 | 12.81 | 0.4 | | | | non isole | dalle béton | 46.35 | 0 | 2 | NULL | | | | non isole | dalle béton | 46.35 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000199N | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1973 | | NULL | 2014-01-14 00:00:00 | NULL | NULL | NULL | 160 | NULL | NULL | NULL | | | C | A | 114.33 | 4.28 | individuel | electricite | pac air/air | | electricite | chaudiere electrique | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 8.8 | 17.97 | 11.71 | 0 | NULL | tout venant | 2.9 | 2.9 | 0.48 | 0 | [ "nord", "ouest", "sud" ] | 0.261 | ITI | NULL | murs en blocs de béton creux | 25 | 108.88 | 108.88 | 108.88 | 0.34 | | | | | dalle béton | 94.55 | 94.55 | 0.34 | NULL | | | | ITI | plafond en plaque de plâtre | 81 | 81 | 0.19 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000201X | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1989 | | NULL | 2014-01-14 00:00:00 | NULL | NULL | NULL | 216 | NULL | NULL | NULL | | | C | D | 119 | 27 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | argon ou krypton | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 3.42 | 6.62 | 3.68 | 4.82 | NULL | tout venant | 2.1 | 2.6 | 0.44 | 0 | [ "est", "nord", "ouest", "sud" ] | 0.079 | ITI | NULL | murs en briques pleines doubles avec lame d'air | 35 | 232.16 | 217.11 | 232.16 | 0.42 | | | | isole | plancher à entrevous isolant | 98.36 | 98.36 | 0.67 | NULL | | | | ITI | plafond avec ou sans remplissage sous combles | 118.16 | 118.16 | 0.3 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000203@ | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2014-01-14 00:00:00 | NULL | NULL | NULL | 31 | NULL | NULL | NULL | | | F | D | 383 | 22 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 4.35 | 0 | 0 | NULL | non traversant | 3.4 | 4.7 | 0.52 | 0 | [ "sud" ] | 0.127 | ITI | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 25 | 62.02 | 29.79 | 34.39 | 2 | | | | non isole | plancher avec ou sans remplissage | 31.19 | 0 | 1.45 | NULL | | | | ITI | plafond avec ou sans remplissage sous combles | 31.19 | 31.19 | 0.24 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000204A | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1983-1988 | 1983 | | NULL | 2014-01-14 00:00:00 | NULL | NULL | NULL | 75 | NULL | NULL | NULL | | | D | A | 172 | 4 | individuel | electricite | generateurs a effet joule | | bois | poele ou insert bois | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 4.02 | 6.03 | 0 | 1.34 | NULL | tout venant | 2.4 | 3 | 0.47 | 0 | [ "est", "nord", "sud" ] | 0.227 | ITI | NULL | murs en briques pleines doubles avec lame d'air | 25 | 38.85 | 38.85 | 38.85 | 0.78 | | | | ITE | plancher à entrevous isolant | 75.2 | 75.2 | 0.29 | NULL | | | | ITI | plafond bois sous solives bois | 75.2 | 75.2 | 0.2 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000207D | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2014-01-14 00:00:00 | NULL | NULL | NULL | 36 | NULL | NULL | NULL | | | D | B | 190 | 7 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | métal sans rupture de pont thermique | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 1.52 | 0 | 0 | 0 | NULL | non traversant | 3.5 | NULL | 0.49 | 0 | [ "nord" ] | 0.281 | non isole | NULL | murs en pierre de taille et moellons avec remplissage tout venant | 60 | 14.65 | 3.89 | 14.65 | 1.6 | | | | non isole | plancher entre solives bois avec ou sans remplissage | 36.32 | 36.32 | 1.1 | NULL | | | | non isole | plafond entre solives bois avec ou sans remplissage | 36.32 | 0 | 1.2 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000209F | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1989-2000 | 2000 | | NULL | 2014-01-15 00:00:00 | NULL | NULL | NULL | 58 | NULL | NULL | NULL | | | D | B | 204 | 10 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | bois | argon ou krypton | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.6 | 2.8 | 3.68 | 0 | | NULL | non isole | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 65 | 59.4 | 0 | 59.4 | 0.3 | | | | non isole | dalle béton | 1.66 | 1.66 | 2 | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000210X | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1989 | | NULL | 2014-01-15 00:00:00 | NULL | NULL | NULL | 42 | NULL | NULL | NULL | | | E | C | 259 | 12 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | air sec | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 0.4 | 1.1 | 0.3 | 0 | NULL | tout venant | 2.2 | 2.7 | 0.44 | 0 | [ "nord", "ouest", "sud" ] | 0.049 | ITI | NULL | murs en blocs de béton creux | 20 | 35.2 | 35.2 | 35.2 | 0.5 | | | | non isole | dalle béton | 42.44 | 42.44 | 0.37 | NULL | | | | ITI | plafond bois sous solives bois | 42.44 | 42.44 | 0.3 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000211Y | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1983-1988 | 1987 | | NULL | 2014-01-15 00:00:00 | NULL | NULL | NULL | 120 | NULL | NULL | NULL | | | D | B | 177.84 | 9.22 | individuel | electricite | pac air/air | | electricite | chaudiere electrique | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0 | 3 | 6.52 | 4.06 | NULL | tout venant | 2.4 | 3 | 0.47 | 1 | [ "est", "ouest", "sud" ] | 0.076 | ITI | NULL | murs en blocs de béton creux | 20 | 187.49 | 164.72 | 187.49 | 0.35 | | | | ITI | dalle béton | 80 | 80 | 0.61 | NULL | | | | ITI | plafond bois sur solives métalliques | 101 | 101 | 0.19 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000213A | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1978-1982 | 1980 | | NULL | 2014-01-15 00:00:00 | NULL | NULL | NULL | 64 | NULL | NULL | NULL | | | D | D | 220.77 | 30.32 | individuel | electricite | generateurs a effet joule | | bois | poele ou insert bois | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0 | 2.58 | 3.62 | 4.15 | NULL | tout venant | 2.2 | 2.7 | 0.44 | 1 | [ "est", "ouest", "sud" ] | 0.138 | ITI | NULL | murs en blocs de béton creux | 20 | 75.41 | 64.71 | 75.41 | 0.54 | | | | non isole | dalle béton | 64.2 | 64.2 | 0.35 | NULL | | | | ITI | plafond en plaque de plâtre | 64.3 | 64.3 | 0.34 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000215C | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1950 | | NULL | 2014-01-15 00:00:00 | NULL | NULL | NULL | 54 | NULL | NULL | NULL | | | E | C | 302.76 | 15.44 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 1.25 | 3.78 | 0 | 2.75 | NULL | tout venant | 2.1 | 2.6 | 0.44 | 1 | [ "est", "nord", "sud" ] | 0.116 | ITI | NULL | murs en blocs de béton creux | 20 | 77.86 | 59.52 | 77.86 | 0.74 | | | | non isole | dalle béton | 54 | 54 | 0.37 | NULL | | | | | plafond en plaque de plâtre | 54 | 54 | 0.19 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000216D | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1974 | | NULL | 2014-01-15 00:00:00 | NULL | NULL | NULL | 115 | NULL | NULL | NULL | | | E | C | 323.55 | 19.22 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 4.08 | 8.76 | 3.52 | 1.96 | NULL | tout venant | 2.4 | NULL | 0.47 | 0 | [ "est", "est ou ouest", "nord", "ouest", "sud" ] | 0.165 | ITI | NULL | murs en blocs de béton creux | 20 | 133.83 | 101.06 | 133.83 | 0.98 | | | | non isole | plancher lourd type entrevous terre-cuite, poutrelles béton | 59 | 59 | 2 | NULL | | | | non isole | plafond lourd type entrevous terre-cuite, poutrelles béton | 63.19 | 63.19 | 2.5 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000219G | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2014-01-15 00:00:00 | NULL | NULL | NULL | 67 | NULL | NULL | NULL | | | D | B | 156 | 6 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | argon ou krypton | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 1.9 | 2.2 | 2.17 | 0 | | NULL | ITI | NULL | murs en béton banché | NULL | 36.3 | 0 | 36.3 | NULL | | | | ITI | dalle béton | 66.66 | 66.66 | 0.19 | NULL | | | | ITI | dalle béton | 66.66 | 66.66 | 0.19 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000220 | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1974 | | NULL | 2014-01-15 00:00:00 | NULL | NULL | NULL | 81 | NULL | NULL | NULL | | | D | E | 174 | 36.56 | individuel | electricite | pac air/eau | | gaz | chaudiere gaz standard | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0 | 0 | 7.1 | 3.34 | NULL | est ouest | 2.1 | 2.6 | 0.44 | 0 | [ "est", "ouest" ] | NULL | ITI | NULL | murs en blocs de béton creux | NULL | 90.72 | 0 | 90.72 | 0.79 | | | | ITE | dalle béton | 49.6 | 49.6 | 0.37 | NULL | | | | ITI | | 49.5 | 49.5 | 0.34 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000221@ | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1974 | | NULL | 2014-01-15 00:00:00 | NULL | NULL | NULL | 81 | NULL | NULL | NULL | | | D | E | 174 | 36.56 | individuel | electricite | pac air/eau | | gaz | chaudiere gaz standard | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0 | 0 | 7.1 | 3.34 | NULL | est ouest | 2.1 | 2.6 | 0.44 | 0 | [ "est", "ouest" ] | NULL | ITI | NULL | murs en blocs de béton creux | NULL | 90.72 | 0 | 90.72 | 0.79 | | | | ITE | dalle béton | 49.6 | 49.6 | 0.37 | NULL | | | | ITI | | 49.5 | 49.5 | 0.34 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000222A | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2014-01-15 00:00:00 | NULL | NULL | NULL | 26 | NULL | NULL | NULL | | | E | C | 330 | 19 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 6.44 | 0 | 0 | NULL | non traversant | 4 | 4.7 | 0.52 | 0 | [ "sud" ] | 0.353 | ITI | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 50 | 50.79 | 11.81 | 21.36 | 2 | | | | non isole | plancher avec ou sans remplissage | 26.19 | 0 | 1.45 | NULL | | | | non isole | plafond avec ou sans remplissage | 26.19 | 0 | 1.45 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000223B | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1978-1982 | 1982 | | NULL | 2014-01-15 00:00:00 | NULL | NULL | NULL | 150 | NULL | NULL | NULL | | | C | D | 143 | 22 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Extracteur mécanique sur conduit non modifié de ventilation naturelle existante | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 5.8 | 4.7 | 6.58 | 0 | | NULL | ITI | NULL | murs en blocs de béton creux | 20 | 155 | 0 | 155 | 0.35 | | | | ITE | voutains en briques ou moellons | 150 | 150 | 0.41 | NULL | | | | | plafond entre solives bois avec ou sans remplissage | 150 | 150 | 0.17 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000225D | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1983-1988 | 1988 | | NULL | 2014-01-15 00:00:00 | NULL | NULL | NULL | 105 | NULL | NULL | NULL | | | D | B | 195 | 10 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 1.35 | 4.82 | 11.31 | NULL | tout venant | 2.5 | 3.2 | 0.43 | 1 | [ "est", "ouest", "sud" ] | 0.179 | ITI | NULL | murs en blocs de béton creux | 20 | 104.06 | 80.23 | 104.06 | 0.78 | | | | non isole | dalle béton | 105 | 105 | 0.37 | NULL | | | | ITI | plafond bois sous solives bois | 105 | 105 | 0.33 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000226E | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2014-01-15 00:00:00 | NULL | NULL | NULL | 51 | NULL | NULL | NULL | | | C | C | 128 | 14 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0 | 0 | 0 | 15 | NULL | non traversant | 2.2 | 2.6 | 0.44 | 0 | [ "est" ] | 0.6 | non isole | NULL | | 0 | 58 | 10 | 21 | 2 | | | | non isole | | 50 | 0 | 2 | NULL | | | | non isole | plafond avec ou sans remplissage | 50 | 0 | 1.45 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000227F | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2001-2005 | 2005 | | NULL | 2014-01-15 00:00:00 | NULL | NULL | NULL | 89 | NULL | NULL | NULL | | | C | A | 107 | 4 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.7 | 2.6 | 3.3 | 0 | | NULL | non isole | NULL | murs en béton banché | 20 | 46.64 | 0 | 46.64 | 0.47 | | | | | | NULL | NULL | NULL | NULL | | | | | dalle béton | 89.4 | 89.4 | 0.3 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000228G | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1969 | | NULL | 2014-01-15 00:00:00 | NULL | NULL | NULL | 110 | NULL | NULL | NULL | | | E | C | 294.94 | 13.64 | individuel | electricite | pac air/air | | electricite | chaudiere electrique | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « avant 1982 » | | simple vitrage | bois | | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 3.36 | 8.6 | 3.12 | 2.64 | NULL | tout venant | 3.8 | 4.5 | 0.48 | 1 | [ "est", "indetermine", "nord", "ouest", "sud" ] | 0.197 | ITI | NULL | murs en blocs de béton creux | NULL | 110.1 | 85.2 | 110.1 | 1.11 | | | | non isole | | NULL | NULL | NULL | NULL | | | | ITE | plafond avec ou sans remplissage sous combles | 110 | 110 | 0.43 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000229H | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2014-01-15 00:00:00 | NULL | NULL | NULL | 82 | NULL | NULL | NULL | | | B | C | 62 | 14 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 14.2 | 5 | 0 | 1.2 | NULL | tout venant | 1.8 | 2.2 | 0.38 | 1 | [ "est", "nord", "sud" ] | 0.319 | ITI | NULL | murs en béton banché | 20 | 44.8 | 43.6 | 44.8 | 0.4 | | | | non isole | dalle béton | 81.5 | 0 | 2 | NULL | | | | non isole | dalle béton | 81.5 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000230@ | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2006-2012 | 2006 | | NULL | 2014-01-16 00:00:00 | NULL | NULL | NULL | 120 | NULL | NULL | NULL | | | C | B | 142 | 6 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 5.08 | 11.56 | 0 | 0 | NULL | nord sud | 2.2 | 2.6 | 0.38 | 0 | [ "nord", "sud" ] | 0.114 | ITI | NULL | murs en blocs de béton creux | 20 | 142.96 | 129.46 | 142.96 | 0.4 | | | | ITE | dalle béton | 60 | 60 | 0.36 | NULL | | | | ITI | plafond avec ou sans remplissage sous combles | 60 | 60 | 0.25 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000232B | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2014-01-16 00:00:00 | NULL | NULL | NULL | 44 | NULL | NULL | NULL | | | F | G | 411 | 96 | individuel | gaz | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 6 | 2 | 0 | 0 | NULL | non traversant | 4 | 4.7 | 0.52 | 1 | [ "nord", "sud" ] | 0.275 | non isole | NULL | murs en blocs de béton creux | 20 | 44.3 | 21.1 | 44.3 | 2 | | | | non isole | dalle béton | 44 | 44 | 2 | NULL | | | | non isole | dalle béton | 44 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000235E | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1970 | | NULL | 2014-01-16 00:00:00 | NULL | NULL | NULL | 19 | NULL | NULL | NULL | | | E | C | 271.76 | 12.51 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « avant 1982 » | | simple vitrage | métal sans rupture de pont thermique | | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 3.6 | 0 | 0 | NULL | non traversant | 4.4 | 6 | 0.64 | 1 | [ "sud" ] | 0.411 | non isole | NULL | murs en béton banché | 22.5 | 11.9 | 5.15 | 11.9 | 0.47 | | | | non isole | dalle béton | 18.96 | 18.96 | 2 | NULL | | | | non isole | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000236F | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1975-1977 | 1977 | | NULL | 2014-01-16 00:00:00 | NULL | NULL | NULL | 92 | NULL | NULL | NULL | | | C | A | 130 | 5 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2 | 2.4 | 3.92 | 0 | | NULL | ITI | NULL | murs en blocs de béton creux | NULL | 85 | 0 | 85 | NULL | | | | non isole | voutains en briques ou moellons | 91 | 91 | 0.8 | NULL | | | | | dalle béton | 91 | 91 | 0.24 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000237 | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1960 | | NULL | 2014-01-16 00:00:00 | NULL | NULL | NULL | 53 | NULL | NULL | NULL | | | E | C | 266.53 | 14.14 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 1.6 | 1.08 | 0 | 0 | NULL | nord sud | 2.7 | 2.7 | 0.44 | 1 | [ "nord", "sud" ] | NULL | non isole | NULL | murs en briques creuses | 33 | 40.28 | 0 | 40.28 | 1.65 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000238H | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1975-1977 | 1975 | | NULL | 2014-01-16 00:00:00 | NULL | NULL | NULL | 45 | NULL | NULL | NULL | | | D | E | 185 | 43 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | simple vitrage | bois | | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 0 | 0 | 9.11 | NULL | non traversant | 3.5 | 4.7 | 0.52 | 0 | [ "est" ] | 0.334 | non isole | NULL | murs en béton banché | 28 | 43.13 | 18.13 | 43.13 | 2 | | | | | dalle béton | 44.98 | 0 | 1 | NULL | | | | ITE | dalle béton | 44.98 | 44.98 | 0.83 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000239I | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2014-01-16 00:00:00 | NULL | NULL | NULL | 81 | NULL | NULL | NULL | | | C | A | 125 | 4 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 0 | 10 | 2 | 2 | NULL | tout venant | 2.1 | 2.6 | 0.44 | 0 | [ "est", "ouest", "sud" ] | 0.215 | ITI | NULL | | 0 | 77 | 51 | 57 | 0.4 | | | | non isole | dalle béton | 80 | 0 | 2 | NULL | | | | ITI | | 80 | 80 | 0.27 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000240A | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2014-01-16 00:00:00 | NULL | NULL | NULL | 48 | NULL | NULL | NULL | | | F | C | 379 | 20 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | métal sans rupture de pont thermique | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 6.72 | 0 | 0 | 0.72 | NULL | non traversant | 3.1 | NULL | 0.54 | 0 | [ "est", "nord" ] | 0.106 | non isole | NULL | murs en blocs de béton creux | 20 | 75.06 | 62.56 | 62.56 | 2 | | | | non isole | dalle béton | 48 | 48 | 0.37 | NULL | | | | non isole | combles aménagés sous rampant | 55 | 55 | 2.5 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000243D | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1989-2000 | 1994 | | NULL | 2014-01-16 00:00:00 | NULL | NULL | NULL | 73 | NULL | NULL | NULL | | | D | B | 191.66 | 9.06 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | métal sans rupture de pont thermique | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 2.99 | 5.82 | 0 | 0 | NULL | nord sud | 3.8 | 4.8 | 0.49 | 0 | [ "nord", "sud" ] | 0.104 | ITI | NULL | murs en béton banché | 20 | 93.75 | 76.15 | 93.75 | 0.43 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000244E | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2014-01-16 00:00:00 | NULL | NULL | NULL | 48 | NULL | NULL | NULL | | | D | B | 199 | 8 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | métal sans rupture de pont thermique | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 6.72 | 0 | 0 | 0.72 | NULL | non traversant | 3.1 | NULL | 0.54 | 0 | [ "est", "nord" ] | 0.106 | ITI | NULL | murs en blocs de béton creux | 20 | 75.06 | 62.56 | 62.56 | 0.35 | | | | non isole | dalle béton | 48 | 48 | 0.37 | NULL | | | | ITI | combles aménagés sous rampant | 55 | 55 | 0.19 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000245F | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1978-1982 | 1978 | | NULL | 2014-01-16 00:00:00 | NULL | NULL | NULL | 96 | NULL | NULL | NULL | | | D | E | 227 | 53 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | métal sans rupture de pont thermique | | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 11.88 | 9.37 | 0 | 0 | NULL | nord sud | 4.6 | NULL | 0.64 | 1 | [ "nord", "sud" ] | 0.341 | non isole | NULL | murs en briques pleines doubles avec lame d'air | 30 | 61.79 | 40.99 | 61.79 | 1.65 | | | | non isole | plancher lourd type entrevous terre-cuite, poutrelles béton | 95.87 | 0 | 2 | NULL | | | | non isole | plafond lourd type entrevous terre-cuite, poutrelles béton | 95.87 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000248 | 13 | 0 | dpe arrêté 2012 facture logement | maison | 2006-2012 | 2006 | | NULL | 2014-01-16 00:00:00 | NULL | NULL | NULL | 0 | NULL | NULL | NULL | | | N | N | 0 | 0 | | | | | | | | 0 | NULL | NULL | | | | | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | | | | métal | | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | | NULL | murs en briques pleines simples | NULL | NULL | NULL | NULL | NULL | | | | | dalle béton | NULL | NULL | NULL | NULL | | | | | plafond avec ou sans remplissage sous combles | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000249J | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1990 | | NULL | 2014-01-16 00:00:00 | NULL | NULL | NULL | 99 | NULL | NULL | NULL | | | D | E | 180.53 | 42.24 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | collectif | | ecs solaire | | gaz | chaudiere gaz standard | | 1 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | air sec | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 7.15 | 3.66 | 2.35 | 0 | NULL | tout venant | 2.1 | 2.6 | 0.44 | 1 | [ "nord", "ouest", "sud" ] | 0.146 | ITI | NULL | murs en blocs de béton creux | 23 | 93.52 | 76.94 | 93.52 | 0.56 | | | | non isole | dalle béton | 98 | 98 | 2 | NULL | | | | ITI | plafond en plaque de plâtre | 98 | 98 | 0.19 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000250B | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2014-01-16 00:00:00 | NULL | NULL | NULL | 104 | NULL | NULL | NULL | | | C | B | 149 | 6 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | métal avec rupture de pont thermique | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 11.18 | 0 | 3.06 | NULL | tout venant | 3.7 | 3.7 | 0.52 | 0 | [ "est", "est ou ouest", "sud" ] | 0.163 | ITI | NULL | murs en blocs de béton creux | 20 | 99.61 | 89.08 | 99.61 | 0.35 | | | | ITI | plancher lourd type entrevous terre-cuite, poutrelles béton | 110 | 0 | 0.36 | NULL | | | | ITI | plafond bois sous solives bois | 111 | 111 | 0.34 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413V1000251C | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1983-1988 | 1983 | | NULL | 2014-01-16 00:00:00 | NULL | NULL | NULL | 100 | NULL | NULL | NULL | | | E | C | 253 | 14 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 5.9 | 4.96 | 4.96 | NULL | tout venant | 2.4 | 3.1 | 0.57 | 1 | [ "est", "ouest", "sud" ] | 0.272 | ITI | NULL | murs en blocs de béton creux | 20 | 60.24 | 42.41 | 60.24 | 0.78 | | | | ITE | plancher lourd type entrevous terre-cuite, poutrelles béton | 100 | 100 | 0.78 | NULL | | | | ITI | plafond bois sous solives bois | 100 | 100 | 0.2 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |