| 1413N1000568F | 13 | 0 | dpe arrêté 2012 facture logement | appartement | avant 1948 | 1947 | | NULL | 2014-02-06 00:00:00 | NULL | NULL | NULL | 50 | NULL | NULL | NULL | | | D | B | 208 | 6 | | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | | | ecs thermodynamique electrique(pac ou ballon) | | | | | 0 | NULL | NULL | 0 | | | triple vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | tout venant (faible) | NULL | NULL | NULL | 0 | [ "nord", "ouest", "sud" ] | NULL | ITI | NULL | murs en béton banché | NULL | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | plafond avec ou sans remplissage sous combles | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000569G | 13 | 0 | dpe arrêté 2012 facture logement | appartement | avant 1948 | 1947 | | NULL | 2014-02-07 00:00:00 | NULL | NULL | NULL | 38 | NULL | NULL | NULL | | | D | B | 194 | 6 | | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | | | double vitrage | bois | argon ou krypton | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | non traversant | NULL | NULL | NULL | 0 | [ "nord" ] | NULL | ITI | NULL | murs en pierre de taille et moellons avec remplissage tout venant | NULL | NULL | NULL | NULL | NULL | | | | non isole | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | combles aménagés sous rampant | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000570Y | 13 | 0 | dpe arrêté 2012 facture logement | appartement | avant 1948 | 1947 | | NULL | 2014-02-07 00:00:00 | NULL | NULL | NULL | 29 | NULL | NULL | NULL | | | D | B | 198 | 6 | | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | | | double vitrage | bois | argon ou krypton | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | non traversant | NULL | NULL | NULL | 0 | [ "nord" ] | NULL | ITI | NULL | murs en pierre de taille et moellons avec remplissage tout venant | NULL | NULL | NULL | NULL | NULL | | | | non isole | dalle béton | NULL | NULL | NULL | NULL | | | | non isole | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000571@ | 13 | 0 | dpe arrêté 2012 facture logement | appartement | avant 1948 | 1947 | | NULL | 2014-02-07 00:00:00 | NULL | NULL | NULL | 32 | NULL | NULL | NULL | | | D | B | 194 | 6 | | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | | | double vitrage | bois | argon ou krypton | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | non traversant | NULL | NULL | NULL | 0 | [ "nord" ] | NULL | ITI | NULL | murs en pierre de taille et moellons avec remplissage tout venant | NULL | NULL | NULL | NULL | NULL | | | | non isole | dalle béton | NULL | NULL | NULL | NULL | | | | non isole | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000572A | 13 | 0 | dpe arrêté 2012 facture logement | appartement | avant 1948 | 1947 | | NULL | 2014-02-07 00:00:00 | NULL | NULL | NULL | 32 | NULL | NULL | NULL | | | D | B | 194 | 6 | | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | | | double vitrage | bois | argon ou krypton | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | non traversant | NULL | NULL | NULL | 0 | [ "nord" ] | NULL | ITI | NULL | murs en pierre de taille et moellons avec remplissage tout venant | NULL | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | non isole | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000646C | 13 | 0 | dpe arrêté 2012 facture logement | maison | 2013-2021 | 2014 | | NULL | 2014-02-13 00:00:00 | NULL | NULL | NULL | 90 | NULL | NULL | NULL | | | B | A | 53.38 | 1.22 | | electricite | generateurs a effet joule | | bois | poele ou insert bois | | 0 | NULL | NULL | | | | | | ecs thermodynamique electrique(pac ou ballon) | | | | | 0 | NULL | NULL | 0 | | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | cloison de plâtre | NULL | NULL | NULL | NULL | NULL | | | | isole | | NULL | NULL | NULL | NULL | | | | isole | plafond en plaque de plâtre | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000650X | 13 | 0 | dpe arrêté 2012 facture logement | maison | 2013-2021 | 2014 | | NULL | 2014-02-20 00:00:00 | NULL | NULL | NULL | 110 | NULL | NULL | NULL | | | A | A | 39.23 | 2.11 | | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | | | ecs thermodynamique electrique(pac ou ballon) | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | argon ou krypton | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | | NULL | | NULL | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000661@ | 13 | 0 | dpe arrêté 2012 facture logement | maison | 2013-2021 | 2014 | | NULL | 2014-02-21 00:00:00 | NULL | NULL | NULL | 90 | NULL | NULL | NULL | | | A | A | 42.72 | 2.31 | | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | | | ecs solaire | | | | | 1 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | isole | NULL | | NULL | NULL | NULL | NULL | NULL | | | | isole | | NULL | NULL | NULL | NULL | | | | isole | | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000768H | 13 | 0 | dpe arrêté 2012 facture logement | maison | | NULL | | NULL | 2014-03-10 00:00:00 | NULL | NULL | NULL | 105 | NULL | NULL | NULL | | | A | A | 34 | 1 | | electricite | pac air/air | | | | | 0 | NULL | NULL | | | | | | ecs thermodynamique electrique(pac ou ballon) | | | | | 0 | NULL | NULL | 0 | | | triple vitrage | pvc | | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | isole | NULL | | NULL | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | NULL | | | | ITI | | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000769I | 13 | 0 | dpe arrêté 2012 facture immeuble | immeuble | 2006-2012 | 2011 | | NULL | 2014-03-10 00:00:00 | NULL | NULL | 765 | NULL | NULL | NULL | NULL | | | C | A | 108.77 | 2.46 | collectif | electricite | pac air/air | | electricite | chaudiere electrique | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en blocs de béton creux | NULL | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000772C | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2013-2021 | 2014 | | NULL | 2014-03-12 00:00:00 | NULL | NULL | NULL | 76 | NULL | NULL | NULL | | | A | A | 40.12 | 4.75 | individuel | solaire | chauffage solaire | | electricite | generateurs a effet joule | | 1 | NULL | NULL | | | | collectif | | ecs solaire | | gaz | chaudiere gaz standard | | 1 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | argon ou krypton | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 15.64 | 0 | 0 | NULL | non traversant | 1.9 | 2.2 | 0.49 | 1 | [ "sud" ] | 0.518 | ITI | NULL | murs en béton banché | NULL | 35.02 | 14.55 | 35.02 | 0.29 | | | | ITE | dalle béton | 75.57 | 75.57 | 0.36 | NULL | | | | non isole | dalle béton | 75.57 | 0 | 2.5 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000851A | 13 | 0 | dpe arrêté 2012 facture logement | maison | | NULL | | NULL | 2014-03-27 00:00:00 | NULL | NULL | NULL | 254 | NULL | NULL | NULL | | | A | A | 36 | 1 | | electricite | pac air/eau | | | | | 0 | NULL | NULL | | | | | | ecs thermodynamique electrique(pac ou ballon) | | | | | 0 | NULL | NULL | 0 | | | triple vitrage | | argon ou krypton | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | | NULL | | NULL | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000852 | 13 | 0 | dpe arrêté 2012 facture logement | maison | | NULL | | NULL | 2014-03-27 00:00:00 | NULL | NULL | NULL | 254 | NULL | NULL | NULL | | | A | A | 36 | 1 | | electricite | pac air/eau | | | | | 0 | NULL | NULL | | | | | | ecs thermodynamique electrique(pac ou ballon) | | | | | 0 | NULL | NULL | 0 | | | triple vitrage | | argon ou krypton | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | | NULL | | NULL | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000853C | 13 | 0 | dpe arrêté 2012 facture logement | maison | | NULL | | NULL | 2014-03-27 00:00:00 | NULL | NULL | NULL | 254 | NULL | NULL | NULL | | | A | A | 36 | 1 | | electricite | pac air/eau | | | | | 0 | NULL | NULL | | | | | | ecs thermodynamique electrique(pac ou ballon) | | | | | 0 | NULL | NULL | 0 | | | triple vitrage | | argon ou krypton | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | | NULL | | NULL | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000857G | 13 | 0 | dpe arrêté 2012 facture logement | appartement | 2013-2021 | 2013 | | NULL | 2014-03-31 00:00:00 | NULL | NULL | NULL | 69 | NULL | NULL | NULL | | | A | B | 35.5 | 8.3 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en béton banché | NULL | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000858H | 13 | 0 | dpe arrêté 2012 facture logement | appartement | 2013-2021 | 2013 | | NULL | 2014-03-31 00:00:00 | NULL | NULL | NULL | 91 | NULL | NULL | NULL | | | A | B | 32.08 | 7.5 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en béton banché | NULL | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000859I | 13 | 0 | dpe arrêté 2012 facture logement | appartement | 2013-2021 | 2013 | | NULL | 2014-03-31 00:00:00 | NULL | NULL | NULL | 44 | NULL | NULL | NULL | | | A | B | 40.07 | 9.37 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en béton banché | NULL | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000860A | 13 | 0 | dpe arrêté 2012 facture logement | appartement | 2013-2021 | 2013 | | NULL | 2014-03-31 00:00:00 | NULL | NULL | NULL | 44 | NULL | NULL | NULL | | | A | B | 40.07 | 9.37 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en béton banché | NULL | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000861B | 13 | 0 | dpe arrêté 2012 facture logement | appartement | 2013-2021 | 2013 | | NULL | 2014-03-31 00:00:00 | NULL | NULL | NULL | 69 | NULL | NULL | NULL | | | A | B | 35.5 | 8.3 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en béton banché | NULL | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000862C | 13 | 0 | dpe arrêté 2012 facture logement | appartement | 2013-2021 | 2013 | | NULL | 2014-03-31 00:00:00 | NULL | NULL | NULL | 57 | NULL | NULL | NULL | | | A | B | 39.89 | 9.33 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en béton banché | NULL | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000863D | 13 | 0 | dpe arrêté 2012 facture logement | appartement | 2013-2021 | 2013 | | NULL | 2014-03-31 00:00:00 | NULL | NULL | NULL | 43 | NULL | NULL | NULL | | | A | B | 40.39 | 9.45 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en béton banché | NULL | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000864E | 13 | 0 | dpe arrêté 2012 facture logement | appartement | 2013-2021 | 2013 | | NULL | 2014-03-31 00:00:00 | NULL | NULL | NULL | 69 | NULL | NULL | NULL | | | A | B | 37.35 | 8.74 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en béton banché | NULL | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000865F | 13 | 0 | dpe arrêté 2012 facture logement | appartement | 2013-2021 | 2013 | | NULL | 2014-03-31 00:00:00 | NULL | NULL | NULL | 91 | NULL | NULL | NULL | | | A | B | 33.93 | 7.93 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en béton banché | NULL | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000866G | 13 | 0 | dpe arrêté 2012 facture logement | appartement | 2013-2021 | 2013 | | NULL | 2014-03-31 00:00:00 | NULL | NULL | NULL | 44 | NULL | NULL | NULL | | | A | B | 42.25 | 9.88 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en béton banché | NULL | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000867H | 13 | 0 | dpe arrêté 2012 facture logement | appartement | 2013-2021 | 2013 | | NULL | 2014-03-31 00:00:00 | NULL | NULL | NULL | 44 | NULL | NULL | NULL | | | A | B | 42.25 | 9.88 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en béton banché | NULL | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000868I | 13 | 0 | dpe arrêté 2012 facture logement | appartement | 2013-2021 | 2013 | | NULL | 2014-03-31 00:00:00 | NULL | NULL | NULL | 69 | NULL | NULL | NULL | | | A | B | 37.35 | 8.74 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en béton banché | NULL | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000869J | 13 | 0 | dpe arrêté 2012 facture logement | appartement | 2013-2021 | 2013 | | NULL | 2014-03-31 00:00:00 | NULL | NULL | NULL | 57 | NULL | NULL | NULL | | | A | B | 39.79 | 9.31 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en béton banché | NULL | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000870B | 13 | 0 | dpe arrêté 2012 facture logement | appartement | 2013-2021 | 2013 | | NULL | 2014-03-31 00:00:00 | NULL | NULL | NULL | 43 | NULL | NULL | NULL | | | A | B | 42.59 | 9.96 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en béton banché | NULL | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000871C | 13 | 0 | dpe arrêté 2012 facture logement | appartement | 2013-2021 | 2013 | | NULL | 2014-03-31 00:00:00 | NULL | NULL | NULL | 69 | NULL | NULL | NULL | | | A | B | 33.65 | 7.87 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en béton banché | NULL | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000872D | 13 | 0 | dpe arrêté 2012 facture logement | appartement | 2013-2021 | 2013 | | NULL | 2014-03-31 00:00:00 | NULL | NULL | NULL | 91 | NULL | NULL | NULL | | | A | B | 30.23 | 7.07 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en béton banché | NULL | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000873E | 13 | 0 | dpe arrêté 2012 facture logement | appartement | 2013-2021 | 2013 | | NULL | 2014-03-31 00:00:00 | NULL | NULL | NULL | 44 | NULL | NULL | NULL | | | A | B | 38.55 | 9.02 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en béton banché | NULL | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000874F | 13 | 0 | dpe arrêté 2012 facture logement | appartement | 2013-2021 | 2013 | | NULL | 2014-03-31 00:00:00 | NULL | NULL | NULL | 44 | NULL | NULL | NULL | | | A | B | 38.55 | 9.02 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en béton banché | NULL | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000875G | 13 | 0 | dpe arrêté 2012 facture logement | appartement | 2013-2021 | 2013 | | NULL | 2014-03-31 00:00:00 | NULL | NULL | NULL | 69 | NULL | NULL | NULL | | | A | B | 33.65 | 7.87 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en béton banché | NULL | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000876H | 13 | 0 | dpe arrêté 2012 facture logement | appartement | 2013-2021 | 2013 | | NULL | 2014-03-31 00:00:00 | NULL | NULL | NULL | 57 | NULL | NULL | NULL | | | A | B | 35.7 | 8.35 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en béton banché | NULL | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000877I | 13 | 0 | dpe arrêté 2012 facture logement | appartement | 2013-2021 | 2013 | | NULL | 2014-03-31 00:00:00 | NULL | NULL | NULL | 43 | NULL | NULL | NULL | | | A | B | 38.89 | 9.1 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en béton banché | NULL | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000878J | 13 | 0 | dpe arrêté 2012 facture logement | appartement | 2013-2021 | 2013 | | NULL | 2014-03-31 00:00:00 | NULL | NULL | NULL | 69 | NULL | NULL | NULL | | | A | B | 33.65 | 7.87 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en béton banché | NULL | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000879K | 13 | 0 | dpe arrêté 2012 facture logement | appartement | 2013-2021 | 2013 | | NULL | 2014-03-31 00:00:00 | NULL | NULL | NULL | 91 | NULL | NULL | NULL | | | A | B | 30.23 | 7.07 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en béton banché | NULL | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000880C | 13 | 0 | dpe arrêté 2012 facture logement | appartement | 2013-2021 | 2013 | | NULL | 2014-03-31 00:00:00 | NULL | NULL | NULL | 44 | NULL | NULL | NULL | | | A | B | 38.55 | 9.02 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en béton banché | NULL | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000881D | 13 | 0 | dpe arrêté 2012 facture logement | appartement | 2013-2021 | 2013 | | NULL | 2014-03-31 00:00:00 | NULL | NULL | NULL | 44 | NULL | NULL | NULL | | | A | B | 38.55 | 9.02 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en béton banché | NULL | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000882E | 13 | 0 | dpe arrêté 2012 facture logement | appartement | 2013-2021 | 2013 | | NULL | 2014-03-31 00:00:00 | NULL | NULL | NULL | 69 | NULL | NULL | NULL | | | A | B | 33.65 | 7.87 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en béton banché | NULL | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000883F | 13 | 0 | dpe arrêté 2012 facture logement | appartement | 2013-2021 | 2013 | | NULL | 2014-03-31 00:00:00 | NULL | NULL | NULL | 57 | NULL | NULL | NULL | | | A | B | 35.7 | 8.35 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en béton banché | NULL | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000884G | 13 | 0 | dpe arrêté 2012 facture logement | appartement | 2013-2021 | 2013 | | NULL | 2014-03-31 00:00:00 | NULL | NULL | NULL | 43 | NULL | NULL | NULL | | | A | B | 38.54 | 9.02 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en béton banché | NULL | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1000888K | 13 | 0 | dpe arrêté 2012 facture logement | maison | 2013-2021 | 2014 | | NULL | 2014-04-03 00:00:00 | NULL | NULL | NULL | 128 | NULL | NULL | NULL | | | A | A | 32 | 1.12 | | electricite | pac indetermine | | electricite | chaudiere electrique | | 0 | NULL | NULL | | | | | | ecs thermodynamique electrique(pac ou ballon) | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | isole | NULL | | NULL | NULL | NULL | NULL | NULL | | | | isole | | NULL | NULL | NULL | NULL | | | | isole | | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1001045W | 13 | 0 | dpe arrêté 2012 facture logement | maison | 2013-2021 | 2014 | | NULL | 2014-04-10 00:00:00 | NULL | NULL | NULL | 79 | NULL | NULL | NULL | | | A | A | 44.6 | 2.51 | | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | | | ecs solaire | | | | | 1 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | argon ou krypton | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | | NULL | | NULL | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | NULL | | | | | plafond avec ou sans remplissage sous combles | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1001248B | 13 | 0 | dpe arrêté 2012 facture logement | maison | 2013-2021 | 2014 | | NULL | 2014-04-15 00:00:00 | NULL | NULL | NULL | 121 | NULL | NULL | NULL | | | A | A | 44.15 | 2.02 | | electricite | pac air/eau | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | | | ecs thermodynamique electrique(pac ou ballon) | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | | | | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | | NULL | | NULL | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | NULL | | | | | plafond avec ou sans remplissage sous combles | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1001358D | 13 | 0 | dpe arrêté 2012 facture logement | maison | 2013-2021 | 2014 | | NULL | 2014-04-24 00:00:00 | NULL | NULL | NULL | 0 | NULL | NULL | NULL | | | A | A | 25 | 2 | | electricite | pac air/eau | | | | | 0 | NULL | NULL | | | | | | ecs thermodynamique electrique(pac ou ballon) | | | | | 0 | NULL | NULL | 0 | | | double vitrage | | argon ou krypton | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en briques creuses | NULL | NULL | NULL | NULL | NULL | | | | isole | plancher à entrevous isolant | NULL | NULL | NULL | NULL | | | | isole | | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1001362Y | 13 | 0 | dpe arrêté 2012 facture logement | maison | 2013-2021 | 2014 | | NULL | 2014-04-25 00:00:00 | NULL | NULL | NULL | 92 | NULL | NULL | NULL | | | A | A | 43.89 | 2.12 | | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | argon ou krypton | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | | NULL | | NULL | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | NULL | | | | isole | | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1001692E | 13 | 0 | dpe arrêté 2012 facture logement | maison | | NULL | | NULL | 2014-04-28 00:00:00 | NULL | NULL | NULL | 105 | NULL | NULL | NULL | | | A | A | 38 | 1 | | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | | | triple vitrage | | | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | | NULL | | NULL | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1001695H | 13 | 0 | dpe arrêté 2012 facture logement | maison | 2013-2021 | 2014 | | NULL | 2014-04-29 00:00:00 | NULL | NULL | NULL | 173 | NULL | NULL | NULL | | | A | A | 27.86 | 1.39 | | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | | NULL | | NULL | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1413N1001696I | 13 | 0 | dpe arrêté 2012 facture logement | maison | 2013-2021 | 2014 | | NULL | 2014-04-29 00:00:00 | NULL | NULL | NULL | 88 | NULL | NULL | NULL | | | A | A | 43.43 | 2.2 | | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | | | ecs solaire | | | | | 1 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | isole | NULL | | NULL | NULL | NULL | NULL | NULL | | | | isole | | NULL | NULL | NULL | NULL | | | | isole | | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |