| 1313L1001454G | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2013-09-13 00:00:00 | NULL | NULL | NULL | 52 | NULL | NULL | NULL | | | D | B | 171.53 | 6.55 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | argon ou krypton | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 3.6 | 0 | 3.45 | 0 | NULL | est ouest | 2.2 | 2.6 | 0.44 | 0 | [ "nord", "ouest" ] | 0.188 | ITI | NULL | murs en béton banché | 20 | 51.7 | 30.45 | 51.7 | 0.43 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001455H | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1965 | | NULL | 2013-09-13 00:00:00 | NULL | NULL | NULL | 89 | NULL | NULL | NULL | | | F | C | 389.1 | 20.12 | individuel | electricite | generateurs a effet joule | | bois | poele ou insert bois | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | métal sans rupture de pont thermique | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 3.51 | 14 | 0 | 0 | NULL | non traversant | 3 | 4 | 0.57 | 0 | [ "nord", "sud" ] | 0.12 | | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 60 | 128 | 128 | 128 | 1.8 | | | | non isole | plancher lourd type entrevous terre-cuite, poutrelles béton | 45 | 45 | 2 | NULL | | | | | plafond lourd type entrevous terre-cuite, poutrelles béton | 45 | 45 | 0.19 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001456I | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-09-13 00:00:00 | NULL | NULL | NULL | 58 | NULL | NULL | NULL | | | E | F | 271 | 63 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | simple vitrage | bois | | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 1.8 | 0 | 3.8 | 3.6 | NULL | tout venant | 4 | 4.7 | 0.52 | 0 | [ "est", "nord", "ouest" ] | 0.144 | non isole | NULL | murs en blocs de béton pleins | 33 | 54.9 | 54.9 | 54.9 | 2 | | | | non isole | dalle béton | 57.83 | 57.83 | 2 | NULL | | | | non isole | dalle béton | 57.83 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001457J | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2013-09-13 00:00:00 | NULL | NULL | NULL | 106 | NULL | NULL | NULL | | | D | B | 156 | 8 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 8 | 0 | 1.5 | NULL | non traversant | 2.2 | 2.6 | 0.44 | 0 | [ "est", "sud" ] | 0.098 | ITI+ITE | NULL | murs en blocs de béton pleins | 30 | 87.5 | 87.5 | 87.5 | 0.98 | | | | non isole | dalle béton | 106.36 | 106.36 | 0.37 | NULL | | | | ITI | plafond bois sur solives bois | 106.36 | 106.36 | 0.24 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001458K | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1978-1982 | 1978 | | NULL | 2013-09-13 00:00:00 | NULL | NULL | NULL | 117 | NULL | NULL | NULL | | | C | B | 140 | 6 | individuel | electricite | pac air/eau | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 2.91 | 9.48 | 0.83 | 1.55 | NULL | tout venant | 3.4 | 4.7 | 0.52 | 0 | [ "est", "nord", "ouest", "sud" ] | 0.114 | ITI | NULL | murs en briques pleines doubles avec lame d'air | 35 | 117.6 | 115.13 | 117.6 | 0.89 | | | | non isole | plancher lourd type entrevous terre-cuite, poutrelles béton | 116.99 | 16.63 | 2 | NULL | | | | ITI | dalle béton | 116.99 | 116.99 | 0.19 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001459L | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2013-09-13 00:00:00 | NULL | NULL | NULL | 33 | NULL | NULL | NULL | | | D | A | 175.65 | 5.14 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0.56 | 0 | 6.02 | 0 | NULL | non traversant | 2.3 | 2.6 | 0.46 | 0 | [ "nord", "ouest" ] | 0.212 | ITI | NULL | murs en béton banché | 20 | 25.46 | 24.47 | 25.46 | 0.4 | | | | non isole | dalle béton | NULL | NULL | NULL | NULL | | | | non isole | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001461E | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-09-13 00:00:00 | NULL | NULL | NULL | 96 | NULL | NULL | NULL | | | C | D | 123 | 28 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 0 | 16.88 | 6.56 | NULL | est ouest | 2.2 | 2.7 | 0.44 | 0 | [ "est", "ouest" ] | 0.418 | non isole | NULL | murs en pierre de taille et moellons avec remplissage tout venant | 50 | 98.67 | 32.57 | 45.67 | 1.9 | | | | non isole | | 96.05 | 0 | 2 | NULL | | | | non isole | plafond entre solives bois avec ou sans remplissage | 96.05 | 0 | 1.2 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001465I | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-09-15 00:00:00 | NULL | NULL | NULL | 50 | NULL | NULL | NULL | | | E | D | 294 | 30 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | argon ou krypton | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 3.12 | 2.08 | 2.48 | NULL | tout venant | 2.1 | 2.6 | 0.44 | 0 | [ "est", "ouest", "sud" ] | 0.106 | non isole | NULL | murs en briques pleines doubles avec lame d'air | 30 | 64.82 | 64.82 | 64.82 | 1.65 | | | | non isole | dalle béton | 49.59 | 0 | 2 | NULL | | | | non isole | plafond avec ou sans remplissage sous combles | 57.99 | 57.99 | 2.5 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001467K | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-09-16 00:00:00 | NULL | NULL | NULL | 58 | NULL | NULL | NULL | | | D | C | 216 | 11 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 5 | 2 | 0 | 2.9 | NULL | tout venant | 2.2 | 2.6 | 0.44 | 0 | [ "est", "nord", "sud" ] | 0.48 | ITI | NULL | murs en béton banché | 30 | 19.72 | 10.72 | 19.72 | 2 | | | | non isole | dalle béton | 58.03 | 0 | 2 | NULL | | | | non isole | dalle béton | 58.03 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001468L | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-09-16 00:00:00 | NULL | NULL | NULL | 52 | NULL | NULL | NULL | | | D | B | 184 | 9 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0 | 0 | 3.2 | 0.74 | NULL | non traversant | 2.2 | 2.6 | 0.44 | 0 | [ "est", "ouest", "sud" ] | 0.119 | ITI | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 40 | 41.77 | 29.06 | 29.06 | 2 | | | | non isole | dalle béton | 52.39 | 0 | 2 | NULL | | | | non isole | dalle béton | 52.39 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001472G | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1983-1988 | 1985 | | NULL | 2013-09-16 00:00:00 | NULL | NULL | NULL | 88 | NULL | NULL | NULL | | | D | C | 225.71 | 11.93 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 6.45 | 8.27 | 0 | 1.72 | NULL | tout venant | 2.2 | 2.2 | 0.38 | 1 | [ "est", "nord", "sud" ] | 0.204 | ITI | NULL | murs en béton banché | 20 | 72.17 | 63.96 | 72.17 | 0.54 | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITE | dalle béton | 87.9 | 87.9 | 0.44 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001473H | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-09-16 00:00:00 | NULL | NULL | NULL | 43 | NULL | NULL | NULL | | | D | C | 184 | 12 | individuel | gaz | chaudiere gaz standard | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0 | 4.88 | 0 | 0 | NULL | non traversant | 2.5 | 3 | 0.44 | 0 | [ "sud" ] | 0.158 | non isole | NULL | murs en pierre de taille et moellons avec remplissage tout venant | 55 | 76.98 | 26.06 | 26.72 | 1.75 | | | | non isole | | 43 | 0 | 2 | NULL | | | | non isole | dalle béton | 43 | 0 | 2.5 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001474I | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1970 | | NULL | 2013-09-16 00:00:00 | NULL | NULL | NULL | 78 | NULL | NULL | NULL | | | D | D | 230.66 | 21.53 | individuel | electricite | pac air/air | | gaz | chaudiere gaz standard | | 0 | NULL | NULL | | | | collectif | | ecs solaire | | gaz | chaudiere gaz standard | | 1 | NULL | NULL | 0 | Ventilation naturelle par conduit avec entrées d’air hygroréglables | | double vitrage | pvc | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 0 | 0 | 0 | NULL | non traversant | 2.5 | 2.7 | 0.44 | 0 | [ "horizontale" ] | 0.146 | non isole | NULL | murs en blocs de béton pleins | 33 | 77.51 | 70.76 | 77.51 | 2 | | | | non isole | dalle béton | 83.7 | 83.7 | 2 | NULL | | | | ITI | dalle béton | 93.23 | 93.23 | 0.56 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001475J | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1989-2000 | 1998 | | NULL | 2013-09-16 00:00:00 | NULL | NULL | NULL | 52 | NULL | NULL | NULL | | | C | A | 91.65 | 4.32 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | chaudiere electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 1.1 | 6.72 | 0 | 0 | NULL | non traversant | 2.2 | 2.7 | 0.44 | 0 | [ "nord", "sud" ] | 0.31 | ITI | NULL | murs en béton banché | 30 | 20.43 | 17.43 | 20.43 | 0.5 | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001481G | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1978-1982 | 1978 | | NULL | 2013-09-16 00:00:00 | NULL | NULL | NULL | 58 | NULL | NULL | NULL | | | D | E | 172 | 40 | individuel | gaz | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | simple vitrage | bois | | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 2.9 | 0 | 0 | 7 | NULL | 90° | 4.1 | 4.8 | 0.56 | 1 | [ "est", "nord" ] | 0.248 | non isole | NULL | murs en béton banché | 20 | 53.1 | 30.1 | 53.1 | 2 | | | | non isole | dalle béton | 57.5 | 0 | 2 | NULL | | | | non isole | dalle béton | 57.5 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001483I | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-09-17 00:00:00 | NULL | NULL | NULL | 63 | NULL | NULL | NULL | | | E | C | 269 | 13 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 4.5 | 4.8 | 3.3 | 0 | NULL | tout venant | 2.2 | 2.6 | 0.44 | 0 | [ "nord", "ouest", "sud" ] | 0.217 | non isole | NULL | murs en béton banché | 30 | 56.4 | 45.4 | 56.4 | 2 | | | | non isole | dalle béton | 63 | 0 | 2 | NULL | | | | non isole | dalle béton | 63 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001484J | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1960 | | NULL | 2013-09-17 00:00:00 | NULL | NULL | NULL | 50 | NULL | NULL | NULL | | | E | E | 231.45 | 41.63 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 4.07 | 0 | 0 | NULL | 90° | 2.4 | 2.6 | 0.4 | 1 | [ "indetermine", "sud" ] | 0.295 | non isole | NULL | murs en béton banché | 20 | 30.33 | 13.66 | 30.33 | 2 | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001485K | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1960 | | NULL | 2013-09-17 00:00:00 | NULL | NULL | NULL | 58 | NULL | NULL | NULL | | | D | D | 174.42 | 21.43 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 0 | 3.64 | 7.4 | NULL | est ouest | 4.1 | 4.8 | 0.56 | 0 | [ "est", "ouest" ] | 0.355 | non isole | NULL | murs en béton banché | 30 | 28.96 | 20.08 | 28.96 | 2 | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001486L | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2013-09-17 00:00:00 | NULL | NULL | NULL | 71 | NULL | NULL | NULL | | | E | F | 294 | 66 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0.29 | 4.73 | 0.2 | 2.68 | NULL | tout venant | 2.3 | 2.9 | 0.47 | 0 | [ "est", "nord", "ouest", "sud" ] | 0.074 | ITI | NULL | murs en blocs de béton pleins | 25 | 131.1 | 98.9 | 131.1 | 0.72 | | | | non isole | dalle béton | 56.79 | 56.79 | 2 | NULL | | | | ITI | plafond bois sous solives bois | 57.66 | 57.66 | 0.52 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001488N | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1960 | | NULL | 2013-09-17 00:00:00 | NULL | NULL | NULL | 63 | NULL | NULL | NULL | | | E | C | 309.66 | 17.4 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0.68 | 0 | 4.84 | 3.73 | NULL | tout venant | 1.5 | 1.5 | 0.4 | 1 | [ "est", "nord", "ouest" ] | NULL | non isole | NULL | murs en blocs de béton pleins | 33 | 65.45 | 0 | 65.45 | 2 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001489O | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2013-09-17 00:00:00 | NULL | NULL | NULL | 68 | NULL | NULL | NULL | | | E | F | 304 | 68 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0.29 | 4.73 | 0.2 | 2.68 | NULL | tout venant | 2.3 | 2.9 | 0.47 | 0 | [ "est", "nord", "ouest", "sud" ] | 0.074 | ITI | NULL | murs en blocs de béton pleins | 25 | 131.1 | 98.9 | 131.1 | 0.72 | | | | non isole | dalle béton | 56.79 | 56.79 | 2 | NULL | | | | ITI | plafond bois sous solives bois | 57.66 | 57.66 | 0.52 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001490G | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1983-1988 | 1988 | | NULL | 2013-09-17 00:00:00 | NULL | NULL | NULL | 59 | NULL | NULL | NULL | | | E | C | 240 | 12 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.7 | 2.6 | 3.75 | 0 | | NULL | non isole | NULL | murs en blocs de béton creux | 20 | 32.84 | 0 | 32.84 | 0.78 | | | | | dalle béton | 59 | 59 | 0.61 | NULL | | | | | plafond bois sous solives bois | 27 | 27 | 0.44 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001491H | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1970 | | NULL | 2013-09-17 00:00:00 | NULL | NULL | NULL | 26 | NULL | NULL | NULL | | | E | C | 287.52 | 13.43 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | simple vitrage | métal sans rupture de pont thermique | | | NULL | 0 | 7.85 | 0 | 0 | 0 | NULL | non traversant | 4.1 | 4.1 | 0.55 | 0 | [ "nord" ] | NULL | non isole | NULL | murs en béton banché | 20 | 10.81 | 0 | 1.48 | 2 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001493J | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2013-09-17 00:00:00 | NULL | NULL | NULL | 65 | NULL | NULL | NULL | | | D | B | 168 | 7 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | métal avec rupture de pont thermique | | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 0 | 0 | 5.5 | 4 | NULL | est ouest | 2.5 | 3.2 | 0.45 | 1 | [ "est", "ouest" ] | 0.17 | ITI | NULL | murs en béton banché | 20 | 47.5 | 46.5 | 47.5 | 0.4 | | | | non isole | dalle béton | 65 | 0 | 2 | NULL | | | | non isole | dalle béton | 65 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001494K | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1989-2000 | 1989 | | NULL | 2013-09-17 00:00:00 | NULL | NULL | NULL | 62 | NULL | NULL | NULL | | | D | A | 154 | 5 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 0 | 0 | 6.5 | 2.6 | NULL | est ouest | 2.2 | 2.7 | 0.51 | 1 | [ "est", "ouest" ] | 0.319 | ITI | NULL | murs en béton banché | 20 | 27.4 | 19.4 | 27.4 | 0.43 | | | | non isole | dalle béton | 62 | 0 | 2 | NULL | | | | non isole | dalle béton | 62 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001495L | 13 | 0 | dpe arrêté 2012 facture logement | appartement | avant 1948 | 1900 | | NULL | 2013-09-18 00:00:00 | NULL | NULL | NULL | 41 | NULL | NULL | NULL | | | N | N | 0 | 0 | | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | | | chaudiere energie indetermine standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | | NULL | | NULL | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001496M | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2013-09-18 00:00:00 | NULL | NULL | NULL | 50 | NULL | NULL | NULL | | | C | D | 111 | 26 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 0 | 9 | 0 | NULL | non traversant | 2.2 | 2.7 | 0.44 | 0 | [ "ouest" ] | 0.279 | ITI | NULL | murs en blocs de béton creux | 25 | 76.33 | 23.21 | 46.21 | 0.4 | | | | | plancher lourd type entrevous terre-cuite, poutrelles béton | 49.5 | 0 | 0.36 | NULL | | | | non isole | plafond lourd type entrevous terre-cuite, poutrelles béton | 49.5 | 0 | 2.5 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001497N | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-09-18 00:00:00 | NULL | NULL | NULL | 55 | NULL | NULL | NULL | | | F | C | 347 | 20 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 4.9 | 4.9 | NULL | est ouest | 3.4 | 4.7 | 0.52 | 0 | [ "est", "ouest" ] | 0.296 | ITI | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 50 | 117.76 | 23.29 | 49.26 | 2 | | | | ITI | plancher avec ou sans remplissage | 54.94 | 0 | 0.87 | NULL | | | | | plafond avec ou sans remplissage | 54.94 | 0 | 1.45 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001498O | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-09-18 00:00:00 | NULL | NULL | NULL | 29 | NULL | NULL | NULL | | | F | C | 391 | 20 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 3.56 | 0 | 0 | 0 | NULL | non traversant | 2.5 | 3 | 0.47 | 0 | [ "nord" ] | 0.261 | non isole | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 35 | 55.9 | 10.06 | 25.26 | 2 | | | | non isole | bardeaux et remplissage | 28.5 | 0 | 1.1 | NULL | | | | ITI | plafond bois sous solives bois | 28.5 | 28.5 | 0.13 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001499P | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-09-18 00:00:00 | NULL | NULL | NULL | 52 | NULL | NULL | NULL | | | D | B | 212 | 9 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0.21 | 10.2 | 0 | 0 | NULL | non traversant | 2.5 | 3 | 0.47 | 0 | [ "nord", "sud" ] | 0.436 | non isole | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 35 | 74.19 | 13.47 | 20.91 | 2 | | | | non isole | plancher entre solives bois avec ou sans remplissage | 52.33 | 0 | 1.1 | NULL | | | | non isole | plafond entre solives bois avec ou sans remplissage | 52.33 | 0 | 1.2 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001500Y | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2013-09-18 00:00:00 | NULL | NULL | NULL | 37 | NULL | NULL | NULL | | | D | B | 181 | 6 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 6.72 | 0 | 0 | NULL | non traversant | 2.4 | 2.9 | 0.4 | 1 | [ "sud" ] | 0.307 | ITI | NULL | murs en béton banché | 22.5 | 58.76 | 15.16 | 28.26 | 0.45 | | | | ITI | dalle béton | 37 | 0 | 0.36 | NULL | | | | ITI | dalle béton | 37 | 0 | 0.25 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001506E | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-09-19 00:00:00 | NULL | NULL | NULL | 56 | NULL | NULL | NULL | | | E | C | 322 | 18 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | métal sans rupture de pont thermique | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 5.1 | 1.5 | 3.5 | 0 | NULL | tout venant | 3.7 | NULL | 0.49 | 1 | [ "nord", "ouest", "sud" ] | 0.337 | ITI | NULL | murs en blocs de béton creux | 25 | 19.9 | 19.9 | 19.9 | 0.4 | | | | non isole | dalle béton | 56.22 | 56.22 | 2 | NULL | | | | non isole | dalle béton | 56.22 | 56.22 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001508G | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1975-1977 | 1975 | | NULL | 2013-09-19 00:00:00 | NULL | NULL | NULL | 90 | NULL | NULL | NULL | | | E | C | 311 | 18 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 0 | 7.12 | 7.36 | NULL | est ouest | 2.2 | 2.6 | 0.46 | 1 | [ "est", "ouest" ] | 0.179 | ITI | NULL | murs en béton banché | 22.5 | 82.91 | 66.24 | 82.91 | 0.98 | | | | ITE | dalle béton | 90.2 | 90.2 | 1 | NULL | | | | | dalle béton | 90.2 | 0 | 0.56 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001509H | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1950 | | NULL | 2013-09-19 00:00:00 | NULL | NULL | NULL | 105 | NULL | NULL | NULL | | | D | E | 204 | 47 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 6.31 | 3.46 | 0 | 3.11 | NULL | tout venant | 3.6 | 3 | 0.52 | 0 | [ "est", "nord", "sud" ] | 0.091 | ITI | NULL | murs en blocs de béton pleins | 23 | 134.97 | 128.97 | 134.97 | 0.9 | | | | non isole | plancher lourd type entrevous terre-cuite, poutrelles béton | 61 | 61 | 2 | NULL | | | | ITI | plafond bois sous solives bois | 58 | 58 | 0.43 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001510@ | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2013-09-19 00:00:00 | NULL | NULL | NULL | 87 | NULL | NULL | NULL | | | D | D | 164 | 35 | individuel | fioul | chaudiere fioul standard | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0 | 4 | 4 | 0 | NULL | est ouest | 2.2 | 2.6 | 0.44 | 0 | [ "ouest", "sud" ] | 0.116 | ITE | NULL | murs en blocs de béton pleins | 30 | 61 | 61 | 61 | 0.4 | | | | non isole | dalle béton | 86.56 | 86.56 | 0.37 | NULL | | | | ITI | plafond bois sous solives bois | 86.56 | 86.56 | 0.21 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001513C | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-09-19 00:00:00 | NULL | NULL | NULL | 72 | NULL | NULL | NULL | | | C | B | 137 | 6 | individuel | electricite | pac eau/eau | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | métal sans rupture de pont thermique | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0 | 0 | 2.11 | 0 | NULL | non traversant | 3.4 | NULL | 0.49 | 0 | [ "nord", "ouest" ] | 0.044 | ITI | NULL | murs en blocs de béton pleins | 30 | 56 | 45.89 | 45.89 | 0.98 | | | | non isole | dalle béton | 71.85 | 71.85 | 0.37 | NULL | | | | ITI | plafond bois sous solives bois | 71.85 | 71.85 | 0.25 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001515E | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1989-2000 | 1998 | | NULL | 2013-09-19 00:00:00 | NULL | NULL | NULL | 52 | NULL | NULL | NULL | | | C | A | 91.65 | 4.32 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | chaudiere electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 1.1 | 6.72 | 0 | 0 | NULL | non traversant | 2.2 | 2.7 | 0.44 | 0 | [ "nord", "sud" ] | 0.31 | ITI | NULL | murs en béton banché | 30 | 20.43 | 17.43 | 20.43 | 0.5 | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001516F | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1970 | | NULL | 2013-09-19 00:00:00 | NULL | NULL | NULL | 72 | NULL | NULL | NULL | | | D | E | 186.8 | 43.71 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | argon ou krypton | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 0 | 18.44 | 13.2 | NULL | est ouest | 1.4 | 1.4 | 0.46 | 0 | [ "est", "ouest" ] | 0.443 | ITI | NULL | murs en blocs de béton creux | 25 | 62.36 | 39.83 | 62.36 | 0.41 | | | | | | NULL | NULL | NULL | NULL | | | | non isole | plafond avec ou sans remplissage sous combles | 71.6 | 71.6 | 2.5 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001519I | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2013-09-19 00:00:00 | NULL | NULL | NULL | 69 | NULL | NULL | NULL | | | C | A | 134 | 5 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | argon ou krypton | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.6 | 2.6 | 3.75 | 0 | | NULL | ITI | NULL | murs en blocs de béton creux | NULL | 57.52 | 0 | 57.52 | NULL | | | | ITE | dalle béton | 69.28 | 69.28 | 0.36 | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001520A | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2013-09-19 00:00:00 | NULL | NULL | NULL | 46 | NULL | NULL | NULL | | | D | B | 220 | 10 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | | métal | | | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en blocs de béton creux | NULL | 34.86 | 0 | 34.86 | NULL | | | | ITE | dalle béton | 45.99 | 45.99 | 0.36 | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001522C | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1949 | | NULL | 2013-09-19 00:00:00 | NULL | NULL | NULL | 35 | NULL | NULL | NULL | | | D | D | 189.94 | 22.58 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | chauffe-eau gaz independant | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | simple vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0 | 3.46 | 0 | 0 | NULL | non traversant | 4.7 | 4.7 | 0.52 | 0 | [ "sud" ] | NULL | non isole | NULL | murs en pierre de taille et moellons avec remplissage tout venant | 50 | 34.45 | 0 | 20.68 | 1.9 | | | | | | NULL | NULL | NULL | NULL | | | | non isole | plafond bois sous solives métalliques | 35.45 | 35.45 | 2.5 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001524E | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2013-09-19 00:00:00 | NULL | NULL | NULL | 43 | NULL | NULL | NULL | | | D | C | 226 | 11 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | | métal | | | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | NULL | NULL | NULL | 0 | | NULL | non isole | NULL | murs en blocs de béton creux | NULL | 42.66 | 0 | 42.66 | NULL | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001525F | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2013-09-19 00:00:00 | NULL | NULL | NULL | 46 | NULL | NULL | NULL | | | E | C | 237 | 11 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | | métal | | | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | NULL | NULL | NULL | 0 | | NULL | ITI | NULL | murs en blocs de béton creux | NULL | 43.11 | 0 | 43.11 | NULL | | | | ITE | dalle béton | 45.99 | 45.99 | 0.36 | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001526G | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2013-09-19 00:00:00 | NULL | NULL | NULL | 70 | NULL | NULL | NULL | | | C | A | 124 | 4 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | argon ou krypton | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 1.9 | 2.2 | 2.51 | 0 | | NULL | ITI | NULL | murs en briques creuses | 33 | 49.34 | 0 | 49.34 | 0.4 | | | | | | NULL | NULL | NULL | NULL | | | | | plafond en plaque de plâtre | 70.3 | 70.3 | 0.25 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001527H | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2013-09-19 00:00:00 | NULL | NULL | NULL | 43 | NULL | NULL | NULL | | | D | B | 172 | 7 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | | métal | | | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | NULL | NULL | NULL | 0 | | NULL | non isole | NULL | murs en blocs de béton creux | NULL | 18.53 | 0 | 18.53 | NULL | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001528I | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2013-09-19 00:00:00 | NULL | NULL | NULL | 37 | NULL | NULL | NULL | | | E | C | 277 | 14 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | argon ou krypton | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.6 | 2.6 | 2.6 | 0 | | NULL | non isole | NULL | murs en blocs de béton creux | 20 | 55.13 | 0 | 55.13 | 0.35 | | | | | | NULL | NULL | NULL | NULL | | | | | combles aménagés sous rampant | 30.86 | 30.86 | 0.25 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001529J | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2013-09-19 00:00:00 | NULL | NULL | NULL | 38 | NULL | NULL | NULL | | | D | B | 181 | 7 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | argon ou krypton | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.6 | 2.6 | 2.6 | 0 | | NULL | ITI | NULL | murs en blocs de béton creux | 20 | 20.24 | 0 | 20.24 | 0.35 | | | | | | NULL | NULL | NULL | NULL | | | | | combles aménagés sous rampant | 32.03 | 32.03 | 0.25 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001530B | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2013-09-19 00:00:00 | NULL | NULL | NULL | 91 | NULL | NULL | NULL | | | C | A | 124 | 5 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | | métal | | | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | NULL | NULL | NULL | 0 | | NULL | non isole | NULL | murs en blocs de béton creux | NULL | 68.06 | 0 | 68.06 | NULL | | | | | | NULL | NULL | NULL | NULL | | | | | combles aménagés sous rampant | 90.76 | 90.76 | 0.25 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001531C | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2013-09-20 00:00:00 | NULL | NULL | NULL | 13 | NULL | NULL | NULL | | | F | C | 430 | 20 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | argon ou krypton | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.6 | 2.6 | 1.1 | 0 | | NULL | ITI | NULL | murs en blocs de béton creux | 20 | 28.54 | 0 | 28.54 | 0.35 | | | | ITE | dalle béton | 13.28 | 13.28 | 0.36 | NULL | | | | | combles aménagés sous rampant | 13.28 | 13.28 | 0.25 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001535G | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-09-20 00:00:00 | NULL | NULL | NULL | 86 | NULL | NULL | NULL | | | F | D | 346 | 21 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 9.09 | 6.83 | 0 | 0 | NULL | nord sud | 2.2 | 2.6 | 0.44 | 0 | [ "nord", "sud" ] | 0.34 | ITI | NULL | murs en pierre de taille et moellons avec remplissage tout venant | 60 | 96.99 | 30.89 | 62.99 | 2 | | | | non isole | plancher lourd type entrevous terre-cuite, poutrelles béton | 85.53 | 85.53 | 2 | NULL | | | | non isole | plafond lourd type entrevous terre-cuite, poutrelles béton | 85.53 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |