| 1313L1001089K | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1983-1988 | 1983 | | NULL | 2013-08-23 00:00:00 | NULL | NULL | NULL | 83 | NULL | NULL | NULL | | | C | D | 94.83 | 22.19 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | collectif | | ecs solaire | | gaz | chaudiere gaz condensation | | 1 | NULL | NULL | 0 | Ventilation mécanique double flux avec échangeur | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 4.91 | 3.08 | 3.14 | NULL | tout venant | 2.3 | 2.8 | 0.44 | 0 | [ "est", "ouest", "sud" ] | 0.186 | ITI | NULL | murs en blocs de béton creux | 20 | 61.72 | 48.62 | 61.72 | 0.35 | | | | ITI | dalle béton | 54.4 | 54.4 | 0.78 | NULL | | | | | plafond bois sous solives bois | 45.6 | 45.6 | 0.18 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001090C | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2013-08-23 00:00:00 | NULL | NULL | NULL | 84 | NULL | NULL | NULL | | | D | B | 210 | 9 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 1.46 | 1.46 | 6.15 | 0 | NULL | tout venant | 2.2 | 2.6 | 0.44 | 1 | [ "nord", "ouest", "sud" ] | 0.139 | ITI | NULL | murs en blocs de béton creux | 20 | 56.41 | 56.41 | 56.41 | 0.4 | | | | ITE | plancher lourd type entrevous terre-cuite, poutrelles béton | 83.5 | 83.5 | 0.36 | NULL | | | | non isole | plafond en plaque de plâtre | 83.5 | 83.5 | 2.5 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001091D | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1975-1977 | 1975 | | NULL | 2013-08-23 00:00:00 | NULL | NULL | NULL | 84 | NULL | NULL | NULL | | | D | B | 162.68 | 6.56 | individuel | electricite | pac air/air | | electricite | chaudiere electrique | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 1.19 | 6.16 | 0 | 0 | NULL | non traversant | 2.4 | 2.9 | 0.48 | 0 | [ "nord", "sud" ] | 0.058 | ITI | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 40 | 119.25 | 119.25 | 119.25 | 0.34 | | | | non isole | dalle béton | 13.2 | 13.2 | 2 | NULL | | | | ITI | combles aménagés sous rampant | 69 | 69 | 0.19 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001092E | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-08-23 00:00:00 | NULL | NULL | NULL | 21 | NULL | NULL | NULL | | | F | C | 373 | 18 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | argon ou krypton | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 5.28 | 0 | 0 | NULL | non traversant | 2.1 | 2.6 | 0.44 | 0 | [ "sud" ] | 0.237 | ITR | NULL | | 0 | 85.47 | 16.98 | 33.96 | 0.98 | | | | ITI | plancher avec ou sans remplissage | 20.78 | 0 | 0.87 | NULL | | | | | plafond avec ou sans remplissage | 20.78 | 0 | 1.45 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001096 | 13 | 0 | dpe arrêté 2012 facture logement | maison | avant 1948 | 1940 | | NULL | 2013-08-23 00:00:00 | NULL | NULL | NULL | 80 | NULL | NULL | NULL | | | N | N | 0 | 0 | | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | bois | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | | NULL | | NULL | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001099L | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1949 | | NULL | 2013-08-23 00:00:00 | NULL | NULL | NULL | 39 | NULL | NULL | NULL | | | F | C | 337.44 | 17.21 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | argon ou krypton | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 2.48 | 7.22 | 0 | 0 | NULL | nord sud | 1.5 | 1.5 | 0.38 | 0 | [ "nord", "sud" ] | NULL | non isole | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 25 | 47.69 | 0 | 47.69 | 2 | | | | | | NULL | NULL | NULL | NULL | | | | ITI | plafond bois sous solives métalliques | 38.9 | 38.9 | 0.19 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001104Y | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1970 | | NULL | 2013-08-25 00:00:00 | NULL | NULL | NULL | 74 | NULL | NULL | NULL | | | D | E | 198 | 46 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 6.3 | 11.03 | 0 | 0 | NULL | nord sud | 3.5 | 4.7 | 0.52 | 0 | [ "nord", "sud" ] | 0.369 | non isole | NULL | murs en blocs de béton creux | 20 | 80.99 | 29.68 | 45.99 | 2 | | | | non isole | dalle béton | 73.71 | 0 | 2 | NULL | | | | non isole | dalle béton | 73.71 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001107B | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1989-2000 | 1990 | | NULL | 2013-08-25 00:00:00 | NULL | NULL | NULL | 65 | NULL | NULL | NULL | | | E | C | 254.34 | 13.05 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | bois | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0.28 | 2.09 | 0 | 2.58 | NULL | tout venant | 2.6 | 3.1 | 0.47 | 0 | [ "est", "nord", "sud" ] | 0.074 | non isole | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 50 | 75 | 61.57 | 75 | 0.58 | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | plafond en plaque de plâtre | 63.4 | 63.4 | 0.24 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001108C | 13 | 0 | dpe arrêté 2012 facture logement | appartement | avant 1948 | 1900 | | NULL | 2013-08-26 00:00:00 | NULL | NULL | NULL | 89 | NULL | NULL | NULL | | | N | N | 0 | 0 | | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit avec entrées d’air hygroréglables | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | | NULL | | NULL | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001110V | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1960 | | NULL | 2013-08-26 00:00:00 | NULL | NULL | NULL | 34 | NULL | NULL | NULL | | | D | B | 220.62 | 9.51 | individuel | electricite | pac air/air | | electricite | chaudiere electrique | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 2.23 | 3.46 | NULL | est ouest | 2.2 | NULL | 0.44 | 0 | [ "est", "ouest" ] | 0.104 | ITI | NULL | | 0 | 49.15 | 49.15 | 49.15 | 0.57 | | | | non isole | dalle béton | 34.11 | 34.11 | 2 | NULL | | | | ITI | plafond bois sous solives bois | 34.1 | 34.1 | 0.18 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001111W | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2013-08-26 00:00:00 | NULL | NULL | NULL | 50 | NULL | NULL | NULL | | | C | A | 135 | 3 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0 | 9.94 | 0 | 0 | NULL | non traversant | 2.3 | 2.7 | 0.57 | 0 | [ "sud" ] | 0.488 | ITI | NULL | murs en béton banché | 20 | 47.16 | 10.42 | 21.86 | 0.4 | | | | | dalle béton | 49.9 | 0 | 0.36 | NULL | | | | | dalle béton | 49.9 | 0 | 0.27 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001113Y | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-08-26 00:00:00 | NULL | NULL | NULL | 30 | NULL | NULL | NULL | | | E | D | 233 | 29 | individuel | electricite | pac indetermine | | gaz | chaudiere gaz standard | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | air sec | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 0 | 0 | 6.27 | 0 | NULL | non traversant | 2.2 | 2.8 | 0.44 | 0 | [ "ouest" ] | 0.306 | non isole | NULL | murs en pierre de taille et moellons avec remplissage tout venant | 50 | 59.98 | 14.23 | 32.48 | 1.9 | | | | non isole | plancher bois sur solives bois | 30 | 0 | 1.6 | NULL | | | | non isole | plafond bois sous solives bois | 30 | 0 | 2.3 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001115A | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-08-26 00:00:00 | NULL | NULL | NULL | 33 | NULL | NULL | NULL | | | D | E | 213 | 49 | individuel | electricite | pac indetermine | | gaz | chaudiere gaz standard | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 0 | 0 | 8.75 | 0 | NULL | non traversant | 2.2 | 2.7 | 0.44 | 0 | [ "ouest" ] | 0.32 | non isole | NULL | murs en pierre de taille et moellons avec remplissage tout venant | 50 | 71.52 | 18.56 | 43.52 | 1.9 | | | | non isole | plancher bois sur solives bois | 32 | 0 | 1.6 | NULL | | | | non isole | plafond bois sous solives bois | 32 | 0 | 2.3 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001118D | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1978-1982 | 1978 | | NULL | 2013-08-26 00:00:00 | NULL | NULL | NULL | 139 | NULL | NULL | NULL | | | B | C | 87.22 | 14.27 | individuel | gaz | chaudiere gaz basse temperature | | bois | poele ou insert bois | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ecs solaire | | gaz | chaudiere gaz basse temperature | | 1 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 14.42 | 15.84 | 0.8 | 0 | NULL | tout venant | 1.5 | 1.5 | 0.44 | 0 | [ "nord", "ouest", "sud" ] | NULL | ITI | NULL | murs en blocs de béton creux | 20 | 155 | 0 | 155 | 0.35 | | | | ITE | | 85 | 85 | 1 | NULL | | | | ITI | plafond en plaque de plâtre | 112 | 112 | 0.19 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001119E | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1950 | | NULL | 2013-08-27 00:00:00 | NULL | NULL | NULL | 106 | NULL | NULL | NULL | | | D | B | 182 | 9 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | bois | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0.98 | 8.4 | 0 | 8.11 | NULL | tout venant | 2.4 | 2.9 | 0.47 | 0 | [ "est", "nord", "sud" ] | 0.114 | ITI | NULL | murs en blocs de béton creux | 20 | 135.5 | 135.5 | 135.5 | 0.35 | | | | non isole | | 106 | 106 | 0.37 | NULL | | | | ITI | plafond bois sous solives bois | 106 | 106 | 0.18 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001121X | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1973 | | NULL | 2013-08-27 00:00:00 | NULL | NULL | NULL | 36 | NULL | NULL | NULL | | | E | C | 267.69 | 12.71 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | | NULL | 0 | 2.93 | 0 | 0 | 1.9 | NULL | 90° | 2.6 | 2.6 | 0.4 | 0 | [ "est", "nord" ] | 0.158 | ITI | NULL | murs en blocs de béton creux | 25 | 35.53 | 25.73 | 35.53 | 0.4 | | | | ITE | dalle béton | 35.89 | 35.89 | 0.36 | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001122Y | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1989-2000 | 1990 | | NULL | 2013-08-27 00:00:00 | NULL | NULL | NULL | 66 | NULL | NULL | NULL | | | D | B | 181.71 | 8.32 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | bois | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 1.24 | 2.36 | 0 | 0 | NULL | nord sud | 2.6 | 3.1 | 0.47 | 0 | [ "nord", "sud" ] | 0.166 | non isole | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 55 | 18.06 | 18.06 | 18.06 | 1.9 | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | plafond en plaque de plâtre | 64.95 | 64.95 | 0.24 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001123@ | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1970 | | NULL | 2013-08-27 00:00:00 | NULL | NULL | NULL | 53 | NULL | NULL | NULL | | | E | C | 274.75 | 13.83 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | bois | air sec | | NULL | 0 | 0 | 0 | 3.4 | 0 | NULL | non traversant | 1.5 | 1.5 | 0.47 | 0 | [ "nord", "ouest" ] | NULL | non isole | NULL | murs en blocs de béton creux | 20 | 30.55 | 0 | 30.55 | 2 | | | | non isole | dalle béton | 50 | 50 | 0.34 | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001124A | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1949 | | NULL | 2013-08-27 00:00:00 | NULL | NULL | NULL | 33 | NULL | NULL | NULL | | | G | D | 504.43 | 29.19 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 0 | 3.6 | 1.71 | NULL | est ouest | 2.5 | 2.7 | 0.44 | 0 | [ "est", "ouest" ] | 0.191 | non isole | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 55 | 42.46 | 22.51 | 42.46 | 1.9 | | | | non isole | | 32.75 | 32.75 | 2 | NULL | | | | ITI | plafond entre solives bois avec ou sans remplissage | NULL | NULL | NULL | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001126C | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1957 | | NULL | 2013-08-27 00:00:00 | NULL | NULL | NULL | 66 | NULL | NULL | NULL | | | D | B | 210.92 | 9.78 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | argon ou krypton | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 9.78 | 6.13 | 0 | NULL | est ouest | 2.3 | 2.5 | 0.4 | 1 | [ "ouest", "sud" ] | 0.38 | non isole | NULL | murs en blocs de béton pleins | 30 | 39.05 | 25.97 | 39.05 | 2 | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001129F | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2001-2005 | 2003 | | NULL | 2013-08-27 00:00:00 | NULL | NULL | NULL | 29 | NULL | NULL | NULL | | | D | B | 203 | 7 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « avant 1982 » | | double vitrage | métal avec rupture de pont thermique | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 5.06 | 0 | 0 | 0 | NULL | non traversant | 2.7 | 3.3 | 0.48 | 0 | [ "nord" ] | 0.316 | ITI | NULL | murs en béton banché | 20 | 46.46 | 10.94 | 19.76 | 0.47 | | | | ITI | dalle béton | 29.36 | 0 | 0.43 | NULL | | | | ITI | dalle béton | 29.36 | 0 | 0.3 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001130X | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1949 | | NULL | 2013-08-27 00:00:00 | NULL | NULL | NULL | 35 | NULL | NULL | NULL | | | E | B | 248.58 | 10.54 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0 | 15.03 | 0 | 0 | NULL | non traversant | 1.5 | 1.5 | 0.52 | 0 | [ "sud" ] | NULL | non isole | NULL | murs en pierre de taille et moellons avec remplissage tout venant | 50 | 31.68 | 0 | 20.4 | 1.9 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001131Y | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-08-27 00:00:00 | NULL | NULL | NULL | 43 | NULL | NULL | NULL | | | E | E | 251 | 37 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 7.08 | 0 | 0 | 0 | NULL | non traversant | 3.4 | 4.7 | 0.52 | 0 | [ "nord" ] | 0.223 | ITI | NULL | | 0 | 58.54 | 24.62 | 38.17 | 0.5 | | | | ITI | plancher avec ou sans remplissage | 43.4 | 0 | 0.87 | NULL | | | | ITI | plafond avec ou sans remplissage sous combles | 43.4 | 43.4 | 0.19 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001133A | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-08-27 00:00:00 | NULL | NULL | NULL | 35 | NULL | NULL | NULL | | | D | B | 185 | 9 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | air sec | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 0.93 | 1.78 | 0 | 0 | NULL | nord sud | 2.1 | 2.6 | 0.44 | 0 | [ "nord", "sud" ] | 0.1 | ITI | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 50 | 29.84 | 24.36 | 29.84 | 0.33 | | | | non isole | | 22.41 | 0 | 2 | NULL | | | | non isole | plafond bois sur solives bois | 32.99 | 9.99 | 2 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001134B | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-08-27 00:00:00 | NULL | NULL | NULL | 56 | NULL | NULL | NULL | | | E | C | 314 | 17 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation hybride | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 3.6 | 0 | 0 | 2 | NULL | 90° | 2.5 | 3 | 0.44 | 0 | [ "est", "nord" ] | 0.215 | non isole | NULL | murs en pierre de taille et moellons avec remplissage tout venant | 50 | 86.3 | 20.4 | 25.5 | 1.9 | | | | non isole | bardeaux et remplissage | 55.8 | 0 | 1.1 | NULL | | | | non isole | bardeaux et remplissage | 55.8 | 0 | 1.2 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001137 | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1970 | | NULL | 2013-08-27 00:00:00 | NULL | NULL | NULL | 102 | NULL | NULL | NULL | | | E | F | 258.51 | 60.49 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « avant 1982 » | | simple vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0 | 15.84 | 4.5 | 6.48 | NULL | tout venant | 1.5 | 1.5 | 0.52 | 1 | [ "est", "ouest", "sud" ] | NULL | ITI | NULL | murs en blocs de béton creux | 20 | 104.84 | 0 | 104.84 | 0.98 | | | | non isole | dalle béton | 130 | 130 | 2 | NULL | | | | ITE | dalle béton | 130 | 130 | 0.24 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001138F | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1970 | | NULL | 2013-08-27 00:00:00 | NULL | NULL | NULL | 102 | NULL | NULL | NULL | | | E | F | 258.51 | 60.49 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « avant 1982 » | | simple vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0 | 15.84 | 4.5 | 6.48 | NULL | tout venant | 1.5 | 1.5 | 0.52 | 1 | [ "est", "ouest", "sud" ] | NULL | ITI | NULL | murs en blocs de béton creux | 20 | 104.84 | 0 | 104.84 | 0.98 | | | | non isole | dalle béton | 130 | 130 | 2 | NULL | | | | ITE | dalle béton | 130 | 130 | 0.24 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001140Y | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-08-27 00:00:00 | NULL | NULL | NULL | 39 | NULL | NULL | NULL | | | F | D | 411 | 25 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 6.9 | 0 | 0 | 0 | NULL | non traversant | 2.4 | 2.6 | 0.44 | 1 | [ "nord" ] | 0.23 | non isole | NULL | murs en béton banché | 20 | 48.2 | 23.1 | 48.2 | 2 | | | | non isole | plancher lourd type entrevous terre-cuite, poutrelles béton | 39.44 | 39.44 | 2 | NULL | | | | non isole | plafond lourd type entrevous terre-cuite, poutrelles béton | 39.44 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001141@ | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1973 | | NULL | 2013-08-28 00:00:00 | NULL | NULL | NULL | 100 | NULL | NULL | NULL | | | E | E | 250.68 | 55.34 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | argon ou krypton | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 2.86 | 7.26 | 2.58 | 1.82 | NULL | tout venant | 2.1 | 2.6 | 0.44 | 1 | [ "est", "nord", "ouest", "sud" ] | 0.149 | non isole | NULL | murs en blocs de béton creux | 25 | 94.08 | 82.88 | 94.08 | 2 | | | | non isole | plancher lourd type entrevous terre-cuite, poutrelles béton | 87 | 87 | 2 | NULL | | | | ITI | plafond lourd type entrevous terre-cuite, poutrelles béton | 83.5 | 83.5 | 0.25 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001142A | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1989-2000 | 2000 | | NULL | 2013-08-28 00:00:00 | NULL | NULL | NULL | 18 | NULL | NULL | NULL | | | F | C | 365 | 18 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | métal sans rupture de pont thermique | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.8 | 4.5 | 5.58 | 0 | | NULL | non isole | NULL | murs en blocs de béton creux | NULL | 20.13 | 0 | 20.13 | NULL | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001144C | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1964 | | NULL | 2013-08-28 00:00:00 | NULL | NULL | NULL | 68 | NULL | NULL | NULL | | | C | D | 121 | 28 | individuel | gaz | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 5.49 | 6.61 | 0 | 0 | NULL | nord sud | 3.4 | 4.5 | 0.48 | 1 | [ "nord", "sud" ] | 0.298 | non isole | NULL | murs en briques pleines doubles avec lame d'air | 25 | 70.73 | 28.5 | 39.65 | 1.85 | | | | non isole | dalle béton | 68.39 | 0 | 2 | NULL | | | | non isole | dalle béton | 68.39 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001146E | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1949 | | NULL | 2013-08-28 00:00:00 | NULL | NULL | NULL | 58 | NULL | NULL | NULL | | | D | E | 170.42 | 39.88 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | gaz | chaudiere gaz standard | | 1 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | argon ou krypton | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 0 | 4.46 | 5.94 | NULL | est ouest | 2 | 2.2 | 0.35 | 1 | [ "est", "ouest" ] | 0.351 | non isole | NULL | murs en blocs de béton pleins | 30 | 33.42 | 19.27 | 33.42 | 2 | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001147F | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1960 | | NULL | 2013-08-28 00:00:00 | NULL | NULL | NULL | 60 | NULL | NULL | NULL | | | D | C | 162.68 | 11.35 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 2.04 | 7.1 | NULL | non traversant | 1.4 | 1.4 | 0.46 | 0 | [ "est", "ouest" ] | NULL | non isole | NULL | murs en béton banché | 30 | 50.01 | 0 | 23.81 | 2 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001150@ | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1989-2000 | 1990 | | NULL | 2013-08-28 00:00:00 | NULL | NULL | NULL | 54 | NULL | NULL | NULL | | | C | A | 137.07 | 3.89 | individuel | electricite | pac air/air | | electricite | chaudiere electrique | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 18.48 | 9.24 | NULL | est ouest | 1.4 | 1.4 | 0.46 | 0 | [ "est", "ouest" ] | NULL | ITI | NULL | murs en blocs de béton creux | 20 | 23.64 | 0 | 23.64 | 0.56 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001152B | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1950 | | NULL | 2013-08-28 00:00:00 | NULL | NULL | NULL | 31 | NULL | NULL | NULL | | | D | B | 218.15 | 8.84 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | simple vitrage | métal sans rupture de pont thermique | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 8 | 0 | 3.52 | NULL | 90° | 3.7 | 3.7 | 0.6 | 0 | [ "est", "sud" ] | NULL | non isole | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 50 | 11.1 | 0 | 11.1 | 2 | | | | non isole | | 31 | 31 | 0.35 | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001154D | 13 | 0 | dpe arrêté 2012 facture logement | appartement | avant 1948 | 1900 | | NULL | 2013-08-29 00:00:00 | NULL | NULL | NULL | 50 | NULL | NULL | NULL | | | N | N | 0 | 0 | | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation hybride avec entrées d’air hygroréglables | | double vitrage | | | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | | NULL | | NULL | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001155E | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1960 | | NULL | 2013-08-29 00:00:00 | NULL | NULL | NULL | 71 | NULL | NULL | NULL | | | D | C | 170.16 | 20.68 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 0 | 16.79 | 0 | NULL | non traversant | 3.7 | NULL | 0.56 | 1 | [ "ouest" ] | 0.592 | non isole | NULL | murs en béton banché | 25 | 19.95 | 11.55 | 19.95 | 2 | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001158H | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-08-29 00:00:00 | NULL | NULL | NULL | 70 | NULL | NULL | NULL | | | F | D | 366 | 30 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 0 | 8.63 | 11.62 | NULL | est ouest | 4.1 | 4.8 | 0.56 | 0 | [ "est", "ouest" ] | 0.45 | non isole | NULL | murs en béton banché | 30 | 63.06 | 24.75 | 34.31 | 2 | | | | non isole | dalle béton | 70.11 | 0 | 2 | NULL | | | | non isole | | 70.11 | 70.11 | 2.5 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001159I | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2006-2012 | 2008 | | NULL | 2013-08-29 00:00:00 | NULL | NULL | NULL | 88 | NULL | NULL | NULL | | | D | B | 151.87 | 6.15 | individuel | electricite | pac air/air | | electricite | chaudiere electrique | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 3.64 | 4.71 | 0 | 1.6 | NULL | tout venant | 1.5 | 1.5 | 0.44 | 1 | [ "est", "nord", "sud" ] | NULL | ITI | NULL | murs en blocs de béton creux | 20 | 77.09 | 0 | 77.09 | 0.4 | | | | | | NULL | NULL | NULL | NULL | | | | ITI | plafond en plaque de plâtre | 72 | 72 | 0.25 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001161B | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-08-29 00:00:00 | NULL | NULL | NULL | 18 | NULL | NULL | NULL | | | E | C | 301.11 | 13.69 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 2.51 | 0 | 0 | 0 | NULL | non traversant | 1.5 | 1.5 | 0.44 | 0 | [ "nord" ] | NULL | non isole | NULL | murs en pierre de taille et moellons avec remplissage tout venant | 50 | 19.58 | 0 | 10.77 | 1.9 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001164E | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-08-29 00:00:00 | NULL | NULL | NULL | 45 | NULL | NULL | NULL | | | E | C | 269 | 12 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 4.8 | 0 | 0 | 0 | NULL | non traversant | 2.4 | NULL | 0.44 | 0 | [ "nord" ] | 0.226 | ITI | NULL | murs en béton banché | 20 | 77.75 | 16.4 | 52.69 | 0.35 | | | | ITE | dalle béton | 54.63 | 54.63 | 0.19 | NULL | | | | ITI | dalle béton | 54.63 | 0 | 1.11 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001165F | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1989 | | NULL | 2013-08-29 00:00:00 | NULL | NULL | NULL | 68 | NULL | NULL | NULL | | | E | C | 257 | 14 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 1.32 | 1.32 | 0 | 2.43 | NULL | tout venant | 2.2 | 2.6 | 0.44 | 0 | [ "est", "nord", "sud" ] | 0.041 | ITI | NULL | murs en blocs de béton creux | 23 | 125.44 | 117.14 | 125.44 | 0.5 | | | | ITE | dalle béton | 56.91 | 56.91 | 0.61 | NULL | | | | ITI | plafond bois sous solives bois | 68.05 | 68.05 | 0.3 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001167H | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-08-29 00:00:00 | NULL | NULL | NULL | 83 | NULL | NULL | NULL | | | E | F | 329 | 61 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 7.2 | 2.4 | 6 | NULL | tout venant | 2.2 | 2.6 | 0.44 | 1 | [ "est", "ouest", "sud" ] | 0.144 | non isole | NULL | murs en blocs de béton creux | 20 | 92.99 | 92.99 | 92.99 | 2 | | | | non isole | plancher lourd type entrevous terre-cuite, poutrelles béton | 83 | 25 | 2 | NULL | | | | non isole | plafond bois sous solives bois | 83 | 83 | 2.3 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001172D | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2001-2005 | 2005 | | NULL | 2013-08-30 00:00:00 | NULL | NULL | NULL | 112 | NULL | NULL | NULL | | | D | B | 194.34 | 9.79 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 2.83 | 6.99 | 5.39 | 0 | NULL | tout venant | 2 | 2.2 | 0.38 | 0 | [ "nord", "ouest", "sud" ] | 0.106 | ITI | NULL | murs en blocs de béton creux | 20 | 143.3 | 128.79 | 143.3 | 0.38 | | | | ITI | plancher avec ou sans remplissage | 94.49 | 94.49 | 0.27 | NULL | | | | ITI | plafond en plaque de plâtre | 95.49 | 95.49 | 0.19 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001173E | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1950 | | NULL | 2013-08-30 00:00:00 | NULL | NULL | NULL | 37 | NULL | NULL | NULL | | | D | B | 183.03 | 7.72 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0.96 | 5.53 | 0 | 0 | NULL | non traversant | 1.5 | 1.5 | 0.44 | 0 | [ "nord", "sud" ] | NULL | non isole | NULL | murs en blocs de béton pleins | 25 | 30.15 | 0 | 30.15 | 0.98 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001174F | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2013-08-30 00:00:00 | NULL | NULL | NULL | 60 | NULL | NULL | NULL | | | C | B | 146 | 7 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 0 | 0 | 10.78 | NULL | non traversant | 2.2 | 2.6 | 0.44 | 1 | [ "est" ] | 0.399 | ITI | NULL | murs en béton banché | 20 | 20.02 | 16.22 | 20.02 | 0.4 | | | | non isole | plancher lourd type entrevous terre-cuite, poutrelles béton | 60 | 0 | 2 | NULL | | | | non isole | plafond lourd type entrevous terre-cuite, poutrelles béton | 60 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001175G | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-08-30 00:00:00 | NULL | NULL | NULL | 68 | NULL | NULL | NULL | | | D | B | 154 | 7 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 6.1 | 4.05 | 0 | 0 | NULL | nord sud | 2.3 | 2.6 | 0.44 | 0 | [ "nord", "sud" ] | 0.268 | ITR | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 40 | 55.98 | 27.78 | 32.98 | 0.98 | | | | non isole | dalle béton | 68.13 | 0 | 2 | NULL | | | | non isole | dalle béton | 68.13 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001176H | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1989 | | NULL | 2013-08-30 00:00:00 | NULL | NULL | NULL | 72 | NULL | NULL | NULL | | | F | D | 414 | 26 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0.46 | 0 | 2.47 | 5.13 | NULL | tout venant | 2.5 | 3.2 | 0.47 | 0 | [ "est", "nord", "ouest" ] | 0.155 | ITI | NULL | murs en blocs de béton creux | 23 | 43.81 | 43.81 | 43.81 | 0.5 | | | | non isole | plancher lourd type entrevous terre-cuite, poutrelles béton | 72.24 | 72.24 | 2 | NULL | | | | non isole | plafond bois sous solives bois | 72.24 | 72.24 | 2.3 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001177I | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1950 | | NULL | 2013-08-30 00:00:00 | NULL | NULL | NULL | 63 | NULL | NULL | NULL | | | D | B | 180.03 | 7.31 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | argon ou krypton | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0.24 | 2.58 | 5.56 | 1.13 | NULL | tout venant | 1.4 | NULL | 0.44 | 1 | [ "est", "nord", "ouest", "sud" ] | 0.164 | ITI | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 30 | 51.73 | 48.44 | 51.73 | 0.24 | | | | non isole | dalle béton | 62.53 | 62.53 | 0.35 | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313L1001178J | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1950 | | NULL | 2013-08-30 00:00:00 | NULL | NULL | NULL | 64 | NULL | NULL | NULL | | | D | B | 161.47 | 6.02 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | argon ou krypton | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0.24 | 1.47 | 3.5 | 1.2 | NULL | tout venant | 1.4 | NULL | 0.44 | 1 | [ "est", "nord", "ouest", "sud" ] | 0.11 | ITI | NULL | murs en blocs de béton creux | 20 | 55.08 | 51.7 | 55.08 | 0.24 | | | | | | NULL | NULL | NULL | NULL | | | | ITI | combles aménagés sous rampant | 61.89 | 61.89 | 0.13 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |