| 1313V1004880N | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1969 | | NULL | 2013-12-02 00:00:00 | NULL | NULL | NULL | 78 | NULL | NULL | NULL | | | F | D | 411.35 | 24.75 | individuel | electricite | chaudiere electrique | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | simple vitrage | bois | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 7.01 | 4.63 | 0 | 0 | NULL | nord sud | 3.4 | 4.5 | 0.48 | 0 | [ "nord", "sud" ] | 0.147 | non isole | NULL | murs en béton banché | NULL | 83.66 | 67.66 | 83.66 | 2 | | | | non isole | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | NULL | NULL | NULL | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004881O | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1974 | | NULL | 2013-12-02 00:00:00 | NULL | NULL | NULL | 167 | NULL | NULL | NULL | | | C | D | 132 | 30 | individuel | fioul | chaudiere fioul basse temperature | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | | | chaudiere fioul basse temperature | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | bois | air sec | | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.7 | 2.8 | 4.51 | 0 | | 0.398 | non isole | NULL | murs en briques pleines doubles avec lame d'air | 30 | 146.36 | 12.5 | 146.36 | 1.65 | | | | non isole | dalle béton | 167 | 167 | 0.32 | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004882P | 13 | 0 | dpe arrêté 2012 facture logement | appartement | avant 1948 | 1900 | | NULL | 2013-12-02 00:00:00 | NULL | NULL | NULL | 41 | NULL | NULL | NULL | | | N | N | 0 | 0 | | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | | NULL | | NULL | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004885S | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-12-02 00:00:00 | NULL | NULL | NULL | 42 | NULL | NULL | NULL | | | E | C | 264 | 14 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 0 | 6.93 | NULL | non traversant | 2.1 | 2.6 | 0.44 | 0 | [ "est" ] | 0.136 | ITI | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 20 | 43.84 | 43.84 | 43.84 | 2 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004886T | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2006-2012 | 2006 | | NULL | 2013-12-02 00:00:00 | NULL | NULL | NULL | 103 | NULL | NULL | NULL | | | C | C | 111 | 16 | individuel | electricite | pac air/air | | gaz | chaudiere gaz standard | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 7.22 | 7 | NULL | est ouest | 2.1 | 2.6 | 0.44 | 0 | [ "est", "ouest" ] | 0.098 | ITI | NULL | murs en blocs de béton creux | 20 | 146.59 | 131.49 | 146.59 | 0.4 | | | | ITE | dalle béton | 62 | 62 | 0.27 | NULL | | | | | plafond bois sous solives bois | 62.7 | 62.7 | 0.25 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004888V | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1951 | | NULL | 2013-12-02 00:00:00 | NULL | NULL | NULL | 68 | NULL | NULL | NULL | | | C | A | 142.21 | 5.37 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 10.28 | 0 | 0 | 0 | NULL | non traversant | 2.7 | 2.7 | 0.44 | 0 | [ "nord" ] | NULL | ITI | NULL | murs en béton banché | 20 | 38.36 | 0 | 38.36 | 0.74 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004889W | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1989 | | NULL | 2013-12-02 00:00:00 | NULL | NULL | NULL | 107 | NULL | NULL | NULL | | | C | D | 129 | 35 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 3.2 | 10.1 | 0 | 1.3 | NULL | tout venant | 2.5 | 3.1 | 0.47 | 0 | [ "est", "nord", "sud" ] | 0.124 | ITI | NULL | murs en blocs de béton creux | 20 | 130.78 | 103.5 | 114 | 0.5 | | | | ITE | dalle béton | 53.5 | 53.5 | 0.61 | NULL | | | | ITI | plafond bois sous solives bois | 53.5 | 53.5 | 0.18 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004890O | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1974 | | NULL | 2013-12-02 00:00:00 | NULL | NULL | NULL | 167 | NULL | NULL | NULL | | | D | B | 161 | 9 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | bois | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.7 | 2.8 | 3.43 | 0 | | 0.113 | non isole | NULL | murs en briques pleines doubles avec lame d'air | 30 | 137.67 | 25 | 137.67 | 1.65 | | | | | | NULL | NULL | NULL | NULL | | | | non isole | dalle béton | 110 | 110 | 2.5 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004892Q | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1974 | | NULL | 2013-12-02 00:00:00 | NULL | NULL | NULL | 48 | NULL | NULL | NULL | | | F | C | 352 | 20 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | simple vitrage | bois | | | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 5.8 | 4.7 | 5.08 | 0 | | 0.075 | non isole | NULL | murs en briques pleines doubles avec lame d'air | 30 | 70.71 | 25 | 70.71 | 1.65 | | | | | | NULL | NULL | NULL | NULL | | | | | plafond bois sous solives bois | 48.37 | 48.37 | 0.41 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004893R | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-12-02 00:00:00 | NULL | NULL | NULL | 66 | NULL | NULL | NULL | | | C | D | 135 | 31 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 0 | 8 | 0 | NULL | non traversant | 2.4 | 2.6 | 0.44 | 0 | [ "ouest" ] | 0.32 | non isole | NULL | | 0 | 70 | 17 | 40 | 2 | | | | non isole | | 66 | 0 | 2 | NULL | | | | non isole | plafond avec ou sans remplissage | 66 | 0 | 1.45 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004894S | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1974 | | NULL | 2013-12-02 00:00:00 | NULL | NULL | NULL | 68 | NULL | NULL | NULL | | | D | D | 179 | 32 | individuel | gaz | chaudiere gaz standard | | bois | poele ou insert bois | | 0 | NULL | NULL | | | | | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | argon ou krypton | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 1.9 | 2.2 | 3.19 | 0 | | NULL | non isole | NULL | murs en béton banché | 30 | 64.01 | 0 | 64.01 | 2 | | | | non isole | dalle béton | 13 | 13 | 2 | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004895T | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2006-2012 | 2006 | | NULL | 2013-12-02 00:00:00 | NULL | NULL | NULL | 90 | NULL | NULL | NULL | | | C | D | 115 | 25 | individuel | gaz | chaudiere gaz condensation | | | | | 0 | NULL | NULL | | | | | | chaudiere gaz condensation | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | argon ou krypton | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 1.9 | 2.2 | 2.25 | 0 | | NULL | ITI | NULL | murs en blocs de béton creux | 20 | 132.14 | 0 | 132.14 | 0.35 | | | | ITE | plancher à entrevous isolant | 48.5 | 48.5 | 0.36 | NULL | | | | | plafond en plaque de plâtre | 49 | 49 | 0.14 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004897V | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1973 | | NULL | 2013-12-03 00:00:00 | NULL | NULL | NULL | 135 | NULL | NULL | NULL | | | E | C | 265.29 | 14.95 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | métal sans rupture de pont thermique | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0 | 15.4 | 3.97 | 1.07 | NULL | non traversant | 2.9 | 3.9 | 0.57 | 0 | [ "est", "ouest", "sud" ] | NULL | ITI | NULL | murs en blocs de béton creux | NULL | 81.56 | 0 | 81.56 | 2 | | | | ITE | | 135 | 135 | 0.32 | NULL | | | | ITI | bardeaux et remplissage | 117.97 | 117.97 | 0.19 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004898W | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1978-1982 | 1982 | | NULL | 2013-12-03 00:00:00 | NULL | NULL | NULL | 110 | NULL | NULL | NULL | | | D | D | 157.53 | 29.42 | individuel | fioul | chaudiere fioul condensation | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit avec entrées d’air hygroréglables | | double vitrage | pvc | air sec | | NULL | 0 | 15.12 | 13.8 | 0 | 0 | NULL | nord sud | 2.6 | 2.6 | NULL | 0 | [ "nord", "sud" ] | 0.265 | ITI | NULL | murs en blocs de béton creux | 20 | 80.11 | 80.11 | 80.11 | 0.35 | | | | ITI | dalle béton | 119.78 | 119.78 | 0.59 | NULL | | | | ITI | dalle béton | 119.78 | 119.78 | 0.61 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004901H | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-12-03 00:00:00 | NULL | NULL | NULL | 72 | NULL | NULL | NULL | | | E | F | 264 | 61 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 2.55 | 6 | 6.9 | NULL | tout venant | 2.4 | 2.6 | 0.44 | 0 | [ "est", "ouest", "sud" ] | 0.18 | non isole | NULL | murs en béton banché | 40 | 70.55 | 70.55 | 70.55 | 2 | | | | non isole | dalle béton | 71.75 | 0 | 2 | NULL | | | | non isole | dalle béton | 71.75 | 71.75 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004906M | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1950 | | NULL | 2013-12-03 00:00:00 | NULL | NULL | NULL | 22 | NULL | NULL | NULL | | | E | A | 308.74 | 4.25 | individuel | bois | poele ou insert bois | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | métal sans rupture de pont thermique | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0 | 0.16 | 4.36 | 0 | NULL | non traversant | 3 | 4.1 | 0.54 | 0 | [ "ouest", "sud" ] | 0.096 | non isole | NULL | murs en briques creuses | 23 | 42.39 | 42.39 | 42.39 | 1.85 | | | | non isole | dalle béton | 21.6 | 21.6 | 0.37 | NULL | | | | ITI | bardeaux et remplissage | 25 | 25 | 0.3 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004907N | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1978-1982 | 1978 | | NULL | 2013-12-03 00:00:00 | NULL | NULL | NULL | 101 | NULL | NULL | NULL | | | E | C | 282 | 14 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | métal sans rupture de pont thermique | | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 1.8 | 6.13 | 3.66 | NULL | tout venant | 3.7 | NULL | 0.49 | 0 | [ "est", "ouest", "sud" ] | 0.071 | ITI | NULL | murs en blocs de béton creux | 20 | 155.82 | 150.66 | 150.66 | 0.89 | | | | non isole | dalle béton | 74 | 74 | 2 | NULL | | | | ITE | dalle béton | 80 | 80 | 0.44 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004908O | 13 | 0 | dpe arrêté 2012 facture logement | maison | avant 1948 | 1928 | | NULL | 2013-12-03 00:00:00 | NULL | NULL | NULL | 70 | NULL | NULL | NULL | | | N | N | 0 | 0 | | bois | poele ou insert bois | | | | | 0 | NULL | NULL | | | | | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | simple vitrage | bois | | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | | NULL | | NULL | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004909 | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1989 | | NULL | 2013-12-03 00:00:00 | NULL | NULL | NULL | 97 | NULL | NULL | NULL | | | D | B | 176 | 7 | individuel | electricite | pac air/air | | bois | poele ou insert bois | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | métal avec rupture de pont thermique | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 1.1 | 7.35 | 2.47 | NULL | tout venant | 2.5 | 3 | 0.41 | 1 | [ "est", "ouest", "sud" ] | 0.142 | ITI | NULL | murs en blocs de béton creux | 20 | 103.9 | 66.1 | 78.9 | 0.35 | | | | ITE | dalle béton | 97 | 97 | 0.61 | NULL | | | | ITI | plafond bois sous solives bois | 97.98 | 97.98 | 0.15 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004910H | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1983-1988 | 1987 | | NULL | 2013-12-03 00:00:00 | NULL | NULL | NULL | 140 | NULL | NULL | NULL | | | E | C | 262 | 13 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 2.49 | 4.79 | 8.77 | 8.61 | NULL | tout venant | 3.2 | 4.5 | 0.48 | 1 | [ "est", "nord", "ouest", "sud" ] | 0.185 | ITI | NULL | murs en blocs de béton creux | 20 | 108.75 | 108.75 | 108.75 | 0.78 | | | | non isole | dalle béton | 140 | 140 | 0.37 | NULL | | | | non isole | plafond bois sous solives bois | 148.44 | 148.44 | 2.3 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004911I | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1955 | | NULL | 2013-12-03 00:00:00 | NULL | NULL | NULL | 74 | NULL | NULL | NULL | | | F | D | 388.18 | 22.42 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 0 | 0 | 3.6 | 2.36 | NULL | tout venant | 3.4 | 4.7 | 0.52 | 0 | [ "est", "indetermine", "ouest" ] | 0.207 | non isole | NULL | murs en blocs de béton creux | 25 | 86.81 | 48.44 | 86.81 | 2 | | | | non isole | dalle béton | 73.5 | 73.5 | 0.35 | NULL | | | | ITI | plafond bois sous solives bois | 73.5 | 73.5 | 0.24 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004912J | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-12-03 00:00:00 | NULL | NULL | NULL | 73 | NULL | NULL | NULL | | | E | C | 243 | 12 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 3.29 | 9.82 | 2.67 | NULL | tout venant | 2.5 | 2.8 | 0.44 | 0 | [ "est", "ouest", "sud" ] | 0.224 | ITI | NULL | murs en béton banché | 30 | 70.66 | 54.67 | 70.66 | 0.34 | | | | non isole | dalle béton | 72.78 | 0 | 2 | NULL | | | | non isole | dalle béton | 72.78 | 72.78 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004915M | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2006-2012 | 2007 | | NULL | 2013-12-03 00:00:00 | NULL | NULL | NULL | 79 | NULL | NULL | NULL | | | D | B | 156.98 | 6.5 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | métal avec rupture de pont thermique | argon ou krypton | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0 | 0 | 5.2 | 2.7 | NULL | est ouest | 2.7 | 3.2 | 0.52 | 0 | [ "est", "ouest" ] | 0.149 | ITI | NULL | murs en blocs de béton creux | 20 | 45.25 | 45.25 | 45.25 | 0.4 | | | | ITE | plancher à entrevous isolant | 40 | 40 | 0.45 | NULL | | | | ITI | plafond en plaque de plâtre | 40 | 40 | 0.25 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004916N | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-12-03 00:00:00 | NULL | NULL | NULL | 38 | NULL | NULL | NULL | | | E | D | 311 | 28 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | bois | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 2.76 | 6.9 | 0 | 0 | NULL | nord sud | 2.5 | 2.8 | 0.5 | 0 | [ "nord", "sud" ] | 0.439 | non isole | NULL | murs en béton banché | 30 | 25.75 | 12.34 | 25.75 | 2 | | | | non isole | dalle béton | 38 | 38 | 2 | NULL | | | | non isole | dalle béton | 38 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004917O | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-12-03 00:00:00 | NULL | NULL | NULL | 62 | NULL | NULL | NULL | | | D | D | 151 | 24 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 6.55 | 5.6 | 0 | 0 | NULL | nord sud | 2.4 | 2.6 | 0.46 | 1 | [ "nord", "sud" ] | 0.369 | non isole | NULL | murs en béton banché | 28 | 30.1 | 20.75 | 30.1 | 2 | | | | non isole | dalle béton | 62.6 | 0 | 2 | NULL | | | | non isole | dalle béton | 62.6 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004920I | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1989 | | NULL | 2013-12-03 00:00:00 | NULL | NULL | NULL | 190 | NULL | NULL | NULL | | | C | C | 100 | 17 | individuel | fioul | chaudiere fioul standard | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0.76 | 2.61 | 0 | 2.47 | NULL | tout venant | 2.4 | 3 | 0.44 | 0 | [ "est", "est ou ouest", "nord", "sud" ] | 0.12 | ITI | NULL | murs en blocs de béton creux | 20 | 179.42 | 168.42 | 179.42 | 0.42 | | | | ITE | plancher lourd type entrevous terre-cuite, poutrelles béton | 95 | 95 | 0.61 | NULL | | | | ITI | plafond bois sous solives bois | 113.26 | 113.26 | 0.18 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004921J | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-12-03 00:00:00 | NULL | NULL | NULL | 67 | NULL | NULL | NULL | | | E | C | 251 | 14 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 1.93 | 7.1 | 0 | 1.55 | NULL | tout venant | 2.2 | 2.6 | 0.44 | 0 | [ "est", "nord", "sud" ] | 0.171 | non isole | NULL | murs en béton banché | 35 | 61.52 | 51.12 | 61.52 | 2 | | | | non isole | dalle béton | 66.98 | 0 | 2 | NULL | | | | non isole | dalle béton | 66.98 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004929R | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1975-1977 | 1975 | | NULL | 2013-12-03 00:00:00 | NULL | NULL | NULL | 83 | NULL | NULL | NULL | | | F | D | 376 | 23 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | simple vitrage | bois | | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 7.62 | 0 | 4.87 | NULL | 90° | 4.1 | 4.8 | 0.56 | 1 | [ "est", "sud" ] | 0.221 | non isole | NULL | murs en blocs de béton pleins | 30 | 64.26 | 44.09 | 64.26 | 2 | | | | non isole | dalle béton | 83.24 | 83.24 | 2 | NULL | | | | non isole | plafond lourd type entrevous terre-cuite, poutrelles béton | 83.24 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004930J | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2013-12-04 00:00:00 | NULL | NULL | NULL | 120 | NULL | NULL | NULL | | | C | D | 113 | 34 | individuel | fioul | chaudiere fioul condensation | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere fioul condensation | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 15.66 | 0 | 0 | NULL | non traversant | 2.2 | 2.6 | 0.44 | 0 | [ "sud" ] | 0.12 | ITI | NULL | murs en briques pleines doubles avec lame d'air | 35 | 114.52 | 114.52 | 114.52 | 0.23 | | | | non isole | plancher lourd type entrevous terre-cuite, poutrelles béton | 120 | 120 | 2 | NULL | | | | ITE | dalle béton | 120 | 120 | 0.19 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004932L | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2013-12-04 00:00:00 | NULL | NULL | NULL | 121 | NULL | NULL | NULL | | | D | E | 193 | 54 | individuel | fioul | chaudiere fioul condensation | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | chaudiere fioul condensation | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 1.5 | 0 | 7.2 | 10.75 | NULL | tout venant | 2.3 | 2.7 | 0.44 | 1 | [ "est", "nord", "ouest" ] | 0.174 | ITI | NULL | murs en briques pleines doubles avec lame d'air | 35 | 92.65 | 92.65 | 92.65 | 2 | | | | non isole | dalle béton | 120.75 | 120.75 | 2 | NULL | | | | ITI | combles aménagés sous rampant | 120.75 | 120.75 | 0.3 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004934N | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1989-2000 | 1989 | | NULL | 2013-12-04 00:00:00 | NULL | NULL | NULL | 38 | NULL | NULL | NULL | | | D | B | 187 | 6 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0 | 0 | 0 | 3.55 | NULL | non traversant | 2.3 | 2.6 | 0.44 | 0 | [ "est" ] | 0.368 | ITI | NULL | murs en béton banché | 20 | 12.1 | 6.1 | 12.1 | 0.5 | | | | non isole | dalle béton | 38.1 | 0 | 2 | NULL | | | | ITI | combles aménagés sous rampant | 37.45 | 37.45 | 0.3 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004936P | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1991 | | NULL | 2013-12-04 00:00:00 | NULL | NULL | NULL | 127 | NULL | NULL | NULL | | | E | C | 262.28 | 13.06 | individuel | electricite | generateurs a effet joule | | bois | poele ou insert bois | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 5.45 | 8.13 | 2.34 | 0 | NULL | tout venant | 3.2 | 3.2 | 0.47 | 1 | [ "nord", "ouest", "sud" ] | 0.202 | ITI | NULL | murs en blocs de béton creux | 20 | 63.19 | 62.75 | 63.19 | 0.5 | | | | non isole | dalle béton | 127.02 | 127.02 | 2 | NULL | | | | ITI | dalle béton | 127.02 | 127.02 | 0.61 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004937Q | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1966 | | NULL | 2013-12-04 00:00:00 | NULL | NULL | NULL | 104 | NULL | NULL | NULL | | | D | F | 209.91 | 62.97 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | collectif | | ecs solaire | | gaz | chaudiere gaz standard | | 1 | NULL | NULL | 0 | Ventilation hybride | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 5.43 | 5.58 | 4.4 | NULL | tout venant | 2.2 | 2.6 | 0.44 | 0 | [ "est", "ouest", "sud" ] | 0.159 | non isole | NULL | murs en blocs de béton creux | 25 | 114.87 | 81.22 | 114.87 | 2 | | | | | dalle béton | 104.11 | 104.11 | 0.35 | NULL | | | | non isole | plafond lourd type entrevous terre-cuite, poutrelles béton | 104.11 | 104.11 | 2.5 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004939S | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2006-2012 | 2008 | | NULL | 2013-12-04 00:00:00 | NULL | NULL | NULL | 180 | NULL | NULL | NULL | | | C | B | 140.67 | 6.18 | individuel | electricite | pac air/eau | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 2.95 | 5.92 | 7.9 | 3.52 | NULL | tout venant | 2.4 | 3 | 0.51 | 0 | [ "est", "nord", "ouest", "sud" ] | NULL | ITI | NULL | murs en blocs de béton creux | NULL | 132.11 | 0 | 132.11 | 0.4 | | | | ITE | | 180 | 180 | 0.34 | NULL | | | | ITI | bardeaux et remplissage | 180 | 180 | 0.17 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004940K | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2013-12-04 00:00:00 | NULL | NULL | NULL | 88 | NULL | NULL | NULL | | | C | B | 128 | 6 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | métal avec rupture de pont thermique | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 3.05 | 7.07 | 1.98 | 0 | NULL | tout venant | 2.6 | 3.3 | 0.52 | 1 | [ "nord", "ouest", "sud" ] | 0.177 | ITI | NULL | murs en béton banché | 20 | 95.7 | 56.4 | 65.1 | 0.4 | | | | non isole | dalle béton | 87 | 17 | 2 | NULL | | | | non isole | dalle béton | 87.58 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004941L | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2006-2012 | 2008 | | NULL | 2013-12-04 00:00:00 | NULL | NULL | NULL | 180 | NULL | NULL | NULL | | | C | B | 140.67 | 6.18 | individuel | electricite | pac air/eau | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 2.95 | 5.92 | 7.9 | 3.52 | NULL | tout venant | 2.4 | 3 | 0.51 | 0 | [ "est", "nord", "ouest", "sud" ] | NULL | ITI | NULL | murs en blocs de béton creux | NULL | 132.11 | 0 | 132.11 | 0.4 | | | | ITE | | 180 | 180 | 0.34 | NULL | | | | ITI | bardeaux et remplissage | 180 | 180 | 0.17 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004942M | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2013-2021 | 2013 | | NULL | 2013-12-04 00:00:00 | NULL | NULL | NULL | 132 | NULL | NULL | NULL | | | B | A | 86.47 | 2.11 | individuel | electricite | pac air/air | | bois | poele ou insert bois | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | métal avec rupture de pont thermique | argon ou krypton | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 7.55 | 19.38 | 0 | 3.33 | NULL | tout venant | 2.5 | 3.2 | 0.56 | 0 | [ "est", "nord", "sud" ] | 0.409 | ITI | NULL | murs en blocs de béton creux | 20 | 52.28 | 43.7 | 52.28 | 0.4 | | | | ITE | plancher à entrevous isolant | 58.5 | 58.5 | 0.45 | NULL | | | | ITI | plafond lourd type entrevous terre-cuite, poutrelles béton | 58.5 | 58.5 | 0.27 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004945P | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 2000 | | NULL | 2013-12-04 00:00:00 | NULL | NULL | NULL | 86 | NULL | NULL | NULL | | | D | B | 189.09 | 7.73 | individuel | electricite | generateurs a effet joule | | bois | poele ou insert bois | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | métal | air sec | | NULL | 0 | 2 | 8 | 0 | 0 | NULL | non traversant | 3.1 | 3.1 | NULL | 0 | [ "nord", "sud" ] | 0.1 | ITI | NULL | murs en blocs de béton creux | 20 | 124 | 90 | 124 | 0.5 | | | | ITI | dalle béton | 63 | 63 | 0.35 | NULL | | | | ITI | plafond en plaque de plâtre | 63 | 63 | 0.19 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004947R | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-12-04 00:00:00 | NULL | NULL | NULL | 51 | NULL | NULL | NULL | | | E | C | 263 | 12 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 6.83 | 6.83 | 0 | 0 | NULL | nord sud | 2.1 | 2.6 | 0.44 | 0 | [ "nord", "sud" ] | 0.36 | non isole | NULL | murs en pierre de taille et moellons avec remplissage tout venant | 50 | 37.43 | 24.33 | 37.43 | 1.9 | | | | non isole | plancher entre solives bois avec ou sans remplissage | 51 | 0 | 1.1 | NULL | | | | non isole | plafond entre solives bois avec ou sans remplissage | 51 | 0 | 1.2 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004949T | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1993 | | NULL | 2013-12-04 00:00:00 | NULL | NULL | NULL | 122 | NULL | NULL | NULL | | | C | D | 100.05 | 23.41 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | bois | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 14.86 | 4.75 | 0 | 0 | NULL | non traversant | 1.4 | 1.4 | 0.5 | 0 | [ "nord", "sud" ] | NULL | ITI | NULL | murs en blocs de béton creux | 20 | 83.17 | 0 | 83.17 | 0.5 | | | | non isole | dalle béton | 38.62 | 13.54 | 0.61 | NULL | | | | ITI | plafond entre solives bois avec ou sans remplissage | 65.13 | 65.13 | 0.3 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004950L | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1983-1988 | 1984 | | NULL | 2013-12-04 00:00:00 | NULL | NULL | NULL | 115 | NULL | NULL | NULL | | | D | B | 190.84 | 9.88 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 2.1 | 6.7 | 1.63 | 0 | NULL | tout venant | 2.4 | NULL | 0.43 | 1 | [ "indetermine", "nord", "ouest", "sud" ] | 0.144 | ITI | NULL | murs en blocs de béton creux | 20 | 124.67 | 95.51 | 124.67 | 0.47 | | | | ITE | plancher à entrevous isolant | 63 | 63 | 0.45 | NULL | | | | ITI | plafond en plaque de plâtre | 63 | 63 | 0.26 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004952N | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1993 | | NULL | 2013-12-04 00:00:00 | NULL | NULL | NULL | 92 | NULL | NULL | NULL | | | D | B | 179.69 | 7.35 | individuel | electricite | generateurs a effet joule | | bois | poele ou insert bois | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 8.2 | 2.8 | 0 | NULL | est ouest | 2.2 | NULL | 0.4 | 0 | [ "ouest", "sud" ] | 0.122 | ITI | NULL | murs en blocs de béton creux | 20 | 101.42 | 79.01 | 101.42 | 0.5 | | | | ITI | plancher lourd type entrevous terre-cuite, poutrelles béton | 92 | 92 | 0.59 | NULL | | | | ITI | plafond en plaque de plâtre | 92 | 92 | 0.19 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004953O | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2001-2005 | 2001 | | NULL | 2013-12-04 00:00:00 | NULL | NULL | NULL | 131 | NULL | NULL | NULL | | | C | A | 107 | 4 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 6.83 | 0 | 15.94 | NULL | 90° | 2.3 | 2.8 | 0.44 | 0 | [ "est", "sud" ] | 0.294 | ITI | NULL | murs en béton banché | 20 | 109.03 | 54.72 | 109.03 | 0.47 | | | | ITI | dalle béton | 131.04 | 131.04 | 0.43 | NULL | | | | non isole | dalle béton | 131.04 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004955Q | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1975-1977 | 1975 | | NULL | 2013-12-04 00:00:00 | NULL | NULL | NULL | 72 | NULL | NULL | NULL | | | D | E | 167 | 50 | individuel | fioul | chaudiere fioul standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere fioul standard | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « avant 1982 » | | simple vitrage | bois | | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 0 | 13.54 | 13.52 | NULL | est ouest | 3.7 | 4.8 | 0.56 | 0 | [ "est", "ouest" ] | 0.884 | ITI | NULL | murs en béton banché | 20 | 61.39 | 3.54 | 19.82 | 1.11 | | | | non isole | dalle béton | 91.5 | 20 | 2 | NULL | | | | non isole | dalle béton | 71.5 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004960M | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1975-1977 | 1975 | | NULL | 2013-12-04 00:00:00 | NULL | NULL | NULL | 77 | NULL | NULL | NULL | | | C | B | 146 | 6 | individuel | bois | chaudiere bois | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 3 | 12 | 0 | 3 | NULL | tout venant | 3.5 | 4.7 | 0.52 | 0 | [ "est", "nord", "sud" ] | 0.514 | ITI | NULL | | 0 | 50 | 17 | 25 | 0.98 | | | | non isole | dalle béton | 77 | 0 | 2 | NULL | | | | non isole | dalle béton | 77 | 0 | 2.5 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004966S | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1989-2000 | 2000 | | NULL | 2013-12-04 00:00:00 | NULL | NULL | NULL | 51 | NULL | NULL | NULL | | | E | C | 258 | 13 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | métal sans rupture de pont thermique | air sec | | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 1.9 | NULL | 7.96 | 1 | | NULL | ITI | NULL | murs en béton banché | 30 | 45.37 | 0 | 45.37 | 0.5 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004967T | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2001-2005 | 2001 | | NULL | 2013-12-04 00:00:00 | NULL | NULL | NULL | 44 | NULL | NULL | NULL | | | D | B | 225 | 10 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 10 | 0 | 0 | 0 | NULL | non traversant | 2.1 | 2.6 | 0.44 | 0 | [ "nord" ] | 0.645 | ITI | NULL | | 0 | 53 | 5.5 | 23 | 0.47 | | | | non isole | dalle béton | 44 | 0 | 2 | NULL | | | | non isole | dalle béton | 44 | 0 | 2.5 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004971O | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1989 | | NULL | 2013-12-05 00:00:00 | NULL | NULL | NULL | 170 | NULL | NULL | NULL | | | D | A | 169 | 3 | individuel | electricite | pac air/air | | bois | poele ou insert bois | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Extracteur mécanique sur conduit non modifié de ventilation naturelle existante | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 1.5 | 2.6 | 6.1 | 9.7 | NULL | tout venant | 2.2 | 2.7 | 0.44 | 0 | [ "est", "nord", "ouest", "sud" ] | 0.124 | ITI | NULL | murs en briques pleines doubles avec lame d'air | 35 | 157.6 | 140.6 | 157.6 | 0.5 | | | | non isole | dalle béton | 44.51 | 44.51 | 0.37 | NULL | | | | ITI | combles aménagés sous rampant | 75.91 | 75.91 | 0.3 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004974R | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2013-12-05 00:00:00 | NULL | NULL | NULL | 79 | NULL | NULL | NULL | | | D | B | 158 | 8 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 0 | 7.47 | 4.58 | NULL | est ouest | 2.2 | 2.7 | 0.44 | 1 | [ "est", "ouest" ] | 0.317 | ITI | NULL | | 0 | 68.95 | 25.95 | 41.95 | 0.4 | | | | non isole | plancher lourd type entrevous terre-cuite, poutrelles béton | 79 | 0 | 2 | NULL | | | | ITE | plafond lourd type entrevous terre-cuite, poutrelles béton | 79 | 79 | 0.27 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1004977U | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-12-05 00:00:00 | NULL | NULL | NULL | 35 | NULL | NULL | NULL | | | E | C | 262 | 12 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 0 | 5.13 | NULL | non traversant | 2.1 | 2.6 | 0.44 | 0 | [ "est" ] | 0.251 | non isole | NULL | murs en pierre de taille et moellons avec remplissage tout venant | 55 | 81.4 | 15.32 | 21.17 | 1.75 | | | | non isole | plancher entre solives bois avec ou sans remplissage | 35.35 | 0 | 1.1 | NULL | | | | non isole | plafond entre solives bois avec ou sans remplissage | 35.35 | 0 | 1.2 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |