| 1313V1003662K | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2013-10-21 00:00:00 | NULL | NULL | NULL | 87 | NULL | NULL | NULL | | | C | B | 141 | 6 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 3.94 | 1.97 | 0 | 0 | NULL | nord sud | 2.3 | 2.7 | 0.46 | 0 | [ "nord", "sud" ] | 0.093 | ITI | NULL | murs en béton banché | 20 | 77.59 | 57.39 | 64.39 | 0.4 | | | | | dalle béton | 86.5 | 0 | 0.36 | NULL | | | | | dalle béton | 86.5 | 0 | 0.25 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003663L | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1978-1982 | 1980 | | NULL | 2013-10-21 00:00:00 | NULL | NULL | NULL | 55 | NULL | NULL | NULL | | | C | A | 109.17 | 2.72 | individuel | solaire | chauffage solaire | | electricite | pac air/air | | 1 | NULL | NULL | | | | individuel | | ecs thermodynamique electrique(pac ou ballon) | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « avant 1982 » | | double vitrage | pvc | air sec | | NULL | 0 | 0 | 0 | 17.02 | 1.18 | NULL | non traversant | 3 | 3 | 0.34 | 0 | [ "est", "ouest" ] | 0.547 | ITI | NULL | | 0 | 20.29 | 15.05 | 20.29 | 0.36 | | | | non isole | dalle béton | 55.07 | 0 | 2 | NULL | | | | non isole | | 55.07 | 0 | 2.5 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003667P | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 2000 | | NULL | 2013-10-21 00:00:00 | NULL | NULL | NULL | 72 | NULL | NULL | NULL | | | D | B | 198 | 9 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 3.1 | 3.1 | 3.03 | 0 | | NULL | ITI | NULL | murs en briques creuses | 33 | 96.72 | 0 | 96.72 | 0.5 | | | | ITE | dalle béton | 37 | 37 | 0.61 | NULL | | | | | plafond en plaque de plâtre | 37 | 37 | 0.19 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003668Q | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-10-22 00:00:00 | NULL | NULL | NULL | 66 | NULL | NULL | NULL | | | D | C | 200 | 20 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | argon ou krypton | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 0 | 6.12 | 13.96 | NULL | est ouest | 1.82 | 2.8 | 0.23 | 0 | [ "est", "ouest" ] | 0.463 | ITI | NULL | murs en béton banché | 20 | 70.87 | 23.3 | 27.85 | 0.43 | | | | ITI | dalle béton | 66.17 | 0 | 0.87 | NULL | | | | non isole | dalle béton | 66.17 | 0 | 2.5 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003669R | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1974 | | NULL | 2013-10-22 00:00:00 | NULL | NULL | NULL | 69 | NULL | NULL | NULL | | | D | E | 213 | 50 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | simple vitrage | bois | | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 1.9 | 2.4 | 4 | 0 | | NULL | non isole | NULL | murs en blocs de béton pleins | NULL | 62.5 | 0 | 62.5 | NULL | | | | ITI | plancher lourd type entrevous terre-cuite, poutrelles béton | 69 | 69 | 0.59 | NULL | | | | ITI | plafond lourd type entrevous terre-cuite, poutrelles béton | 69 | 69 | 0.61 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003670J | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-10-22 00:00:00 | NULL | NULL | NULL | 51 | NULL | NULL | NULL | | | D | E | 222 | 52 | individuel | gaz | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 1.56 | 0 | 4.91 | 0 | NULL | non traversant | 2.4 | 2.6 | 0.44 | 0 | [ "nord", "ouest" ] | 0.106 | non isole | NULL | murs en blocs de béton creux | 20 | 90.44 | 54.44 | 54.44 | 2 | | | | non isole | | 51.41 | 51.41 | 0.37 | NULL | | | | ITI | plafond bois sous solives bois | 51.41 | 51.41 | 0.18 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003671K | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1989 | | NULL | 2013-10-22 00:00:00 | NULL | NULL | NULL | 80 | NULL | NULL | NULL | | | D | C | 216 | 12 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 1.2 | 6.38 | 3.2 | NULL | tout venant | 2.2 | 2.7 | 0.44 | 0 | [ "est", "ouest", "sud" ] | 0.147 | ITI | NULL | murs en blocs de béton creux | 0 | 62.5 | 62.5 | 62.5 | 0.5 | | | | ITE | plancher lourd type entrevous terre-cuite, poutrelles béton | 79 | 79 | 0.61 | NULL | | | | ITI | plafond bois sous solives bois | 79 | 79 | 0.3 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003672L | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2013-10-22 00:00:00 | NULL | NULL | NULL | 86 | NULL | NULL | NULL | | | C | B | 142 | 6 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction hygroréglable | | double vitrage | pvc | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 3.94 | 1.97 | 0 | 0 | NULL | nord sud | 2.3 | 2.7 | 0.46 | 0 | [ "nord", "sud" ] | 0.093 | ITI | NULL | murs en béton banché | 20 | 77.59 | 57.39 | 64.39 | 0.4 | | | | | dalle béton | 86.5 | 0 | 0.36 | NULL | | | | | dalle béton | 86.5 | 0 | 0.25 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003674N | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1974 | | NULL | 2013-10-22 00:00:00 | NULL | NULL | NULL | 61 | NULL | NULL | NULL | | | E | F | 277 | 65 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | | | chauffe-eau gaz independant | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | argon ou krypton | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.8 | 2.7 | 0.62 | 0 | | NULL | non isole | NULL | murs en blocs de béton creux | 20 | 69.94 | 0 | 69.94 | 2 | | | | non isole | dalle béton | 31.33 | 31.33 | 2 | NULL | | | | | plafond entre solives bois avec ou sans remplissage | 32.87 | 32.87 | 1.2 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003675O | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-10-22 00:00:00 | NULL | NULL | NULL | 66 | NULL | NULL | NULL | | | E | C | 242 | 13 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | argon ou krypton | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 4.11 | 6.36 | 0 | 0 | NULL | nord sud | 2.1 | 2.6 | 0.44 | 0 | [ "nord", "sud" ] | 0.246 | non isole | NULL | murs en briques pleines doubles avec lame d'air | 35 | 82.38 | 32.14 | 33.55 | 1.55 | | | | non isole | plancher avec ou sans remplissage | 66.03 | 0 | 1.45 | NULL | | | | ITI | plafond avec ou sans remplissage sous combles | 66.03 | 66.03 | 0.24 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003676P | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1983-1988 | 1983 | | NULL | 2013-10-22 00:00:00 | NULL | NULL | NULL | 97 | NULL | NULL | NULL | | | D | D | 157 | 27 | individuel | gaz | chaudiere gaz basse temperature | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0.4 | 1.3 | 0.4 | 5.2 | NULL | tout venant | 3.4 | 4.7 | 0.52 | 1 | [ "est", "nord", "ouest", "sud" ] | 0.049 | ITI | NULL | murs en blocs de béton creux | 20 | 142.8 | 142.8 | 142.8 | 0.35 | | | | ITE | dalle béton | 49.71 | 49.71 | 0.37 | NULL | | | | ITI | combles aménagés sous rampant | 47.17 | 47.17 | 0.33 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003677Q | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-10-22 00:00:00 | NULL | NULL | NULL | 53 | NULL | NULL | NULL | | | E | C | 306 | 17 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 4.7 | 4.7 | 0.6 | 0 | NULL | tout venant | 2.2 | 2.7 | 0.44 | 1 | [ "nord", "ouest", "sud" ] | 0.196 | ITI | NULL | murs en béton banché | 30 | 57 | 41 | 50 | 2 | | | | non isole | plancher lourd type entrevous terre-cuite, poutrelles béton | 53 | 0 | 2 | NULL | | | | ITI | plafond lourd type entrevous terre-cuite, poutrelles béton | 53 | 0 | 0.25 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003679S | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1948 | | NULL | 2013-10-22 00:00:00 | NULL | NULL | NULL | 118 | NULL | NULL | NULL | | | D | D | 151 | 35 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | simple vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 10.66 | 11.07 | 0 | 0 | NULL | nord sud | 3.4 | 4.7 | 0.52 | 0 | [ "nord", "sud" ] | 0.186 | ITI | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 45 | 129.22 | 94.88 | 129.22 | 0.98 | | | | ITE | dalle béton | 71.46 | 71.46 | 0.37 | NULL | | | | ITI | plafond bois sous solives bois | 70.15 | 70.15 | 0.18 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003680K | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2001-2005 | 2001 | | NULL | 2013-10-22 00:00:00 | NULL | NULL | NULL | 124 | NULL | NULL | NULL | | | B | B | 88 | 6 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Extracteur mécanique sur conduit non modifié de ventilation naturelle existante | | double vitrage | métal sans rupture de pont thermique | air sec | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 1.2 | 8 | 6.3 | 1.2 | NULL | tout venant | 3.2 | NULL | 0.49 | 0 | [ "est", "nord", "ouest", "sud" ] | 0.149 | ITI | NULL | murs en blocs de béton creux | 25 | 95.3 | 95.3 | 95.3 | 0.47 | | | | ITE | dalle béton | 124.12 | 124.12 | 0.43 | NULL | | | | ITI | plafond bois sous solives bois | 124.12 | 124.12 | 0.13 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003681L | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-10-22 00:00:00 | NULL | NULL | NULL | 55 | NULL | NULL | NULL | | | F | F | 365 | 74 | individuel | fioul | chaudiere fioul standard | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | simple vitrage | bois | | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 9.68 | 0 | 9.68 | NULL | 90° | 4 | 4.7 | 0.52 | 1 | [ "est", "sud" ] | 0.415 | non isole | NULL | murs en briques pleines doubles avec lame d'air | 30 | 66.73 | 27.31 | 38.56 | 1.65 | | | | non isole | dalle béton | 55.36 | 0 | 2 | NULL | | | | non isole | dalle béton | 55.36 | 0 | 2.5 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003683N | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1989 | | NULL | 2013-10-22 00:00:00 | NULL | NULL | NULL | 155 | NULL | NULL | NULL | | | D | B | 193 | 10 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Extracteur mécanique sur conduit non modifié de ventilation naturelle existante | | double vitrage | métal avec rupture de pont thermique | | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0.3 | 7.55 | 8.4 | 1.75 | NULL | tout venant | 2.7 | 3.2 | 0.52 | 0 | [ "est", "nord", "ouest", "sud" ] | 0.091 | ITI | NULL | murs en béton banché | 20 | 180 | 180 | 180 | 0.5 | | | | ITE | plancher à entrevous isolant | 120 | 120 | 0.61 | NULL | | | | ITI | plafond bois sous solives bois | 125 | 125 | 0.3 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003685P | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-10-22 00:00:00 | NULL | NULL | NULL | 86 | NULL | NULL | NULL | | | D | E | 199 | 36 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | argon ou krypton | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 6.45 | 6.18 | 0 | 0 | NULL | nord sud | 2.1 | 2.6 | 0.44 | 0 | [ "nord", "sud" ] | 0.291 | non isole | NULL | murs en pierre de taille et moellons constitué d'un seul matériaux | 50 | 133.1 | 30.78 | 52.75 | 2 | | | | non isole | plancher avec ou sans remplissage | 86.39 | 0 | 1.45 | NULL | | | | non isole | plafond avec ou sans remplissage | 86.39 | 0 | 1.45 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003686Q | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1974 | | NULL | 2013-10-22 00:00:00 | NULL | NULL | NULL | 64 | NULL | NULL | NULL | | | D | E | 180 | 42 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « avant 1982 » | | | bois | | | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | NULL | NULL | NULL | 1 | | NULL | non isole | NULL | murs en béton banché | 20 | 24.74 | 0 | 24.74 | 2 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003687R | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1978-1982 | 1978 | | NULL | 2013-10-22 00:00:00 | NULL | NULL | NULL | 88 | NULL | NULL | NULL | | | C | D | 141 | 33 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | métal sans rupture de pont thermique | | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 3.32 | 11.57 | 0 | 0 | NULL | non traversant | 3.5 | NULL | 0.49 | 0 | [ "nord", "sud" ] | NULL | ITI | NULL | murs en blocs de béton creux | 23 | 77.44 | 0 | 77.44 | 2 | | | | non isole | dalle béton | 59 | 59 | 2 | NULL | | | | ITI | combles aménagés sous rampant | 76.7 | 76.7 | 0.87 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003689T | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1989 | | NULL | 2013-10-22 00:00:00 | NULL | NULL | NULL | 110 | NULL | NULL | NULL | | | D | B | 155 | 7 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 2.95 | 7.93 | 0 | 0 | NULL | nord sud | 2.5 | NULL | 0.47 | 1 | [ "nord", "sud" ] | 0.147 | ITI | NULL | murs en béton banché | 20 | 72.99 | 62.99 | 72.99 | 0.63 | | | | ITE | plancher lourd type entrevous terre-cuite, poutrelles béton | 110 | 110 | 0.37 | NULL | | | | ITI | plafond bois sous solives bois | 110 | 110 | 0.18 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003690L | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1989-2000 | 1990 | | NULL | 2013-10-22 00:00:00 | NULL | NULL | NULL | 18 | NULL | NULL | NULL | | | E | B | 248 | 8 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 4.6 | 0 | 0 | NULL | non traversant | 2.7 | NULL | 0.51 | 1 | [ "sud" ] | 0.487 | non isole | NULL | murs en béton banché | 20 | 42.81 | 4.85 | 12.43 | 0.35 | | | | ITI | dalle béton | 22.7 | 0 | 1.35 | NULL | | | | non isole | dalle béton | 22.7 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003691M | 13 | 0 | dpe arrêté 2012 facture logement | appartement | avant 1948 | 1900 | | NULL | 2013-10-22 00:00:00 | NULL | NULL | NULL | 526 | NULL | NULL | NULL | | | N | N | 0 | 0 | | gaz | radiateurs gaz | | | | | 0 | NULL | NULL | | | | | | chauffe-eau independant indetermine | | | | | 0 | NULL | NULL | 0 | | | double vitrage | bois | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | | NULL | | NULL | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003693O | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1969 | | NULL | 2013-10-22 00:00:00 | NULL | NULL | NULL | 60 | NULL | NULL | NULL | | | G | D | 491.07 | 24.82 | individuel | electricite | generateurs a effet joule | | bois | poele ou insert bois | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | bois | air sec | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 0 | 0 | 0 | NULL | 90° (faible) | 2.9 | NULL | 0.47 | 0 | [ "horizontale", "indetermine" ] | 0.16 | ITI | NULL | murs en blocs de béton pleins | 33 | 73.22 | 60.94 | 73.22 | 2 | | | | non isole | dalle béton | 60 | 60 | 2 | NULL | | | | ITI | dalle béton | 60 | 60 | 0.43 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003694P | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1983-1988 | 1988 | | NULL | 2013-10-22 00:00:00 | NULL | NULL | NULL | 89 | NULL | NULL | NULL | | | E | C | 250.65 | 13.57 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation naturelle par conduit avec entrées d’air hygroréglables | | double vitrage | pvc | air sec | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 0 | 0 | 0 | 0 | NULL | non traversant | 2.9 | 2.7 | 0.57 | 0 | [ "horizontale" ] | 0.204 | ITI | NULL | murs en béton banché | 30 | 69.4 | 41.4 | 69.4 | 2 | | | | ITI | dalle béton | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | 89.4 | 89.4 | 0.25 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003695Q | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2006-2012 | 2007 | | NULL | 2013-10-22 00:00:00 | NULL | NULL | NULL | 134 | NULL | NULL | NULL | | | C | A | 109.43 | 4.1 | individuel | electricite | pac air/air | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 3.61 | 10.75 | 1.79 | 5.45 | NULL | tout venant | 3 | 2.6 | 0.57 | 1 | [ "est", "nord", "ouest", "sud" ] | 0.17 | ITI | NULL | murs en blocs de béton creux | 20 | 125.12 | 105.74 | 125.12 | 0.38 | | | | ITE | plancher à entrevous isolant | 134 | 134 | 0.16 | NULL | | | | ITI | plafond en plaque de plâtre | 134 | 134 | 0.19 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003697 | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 2000 | | NULL | 2013-10-22 00:00:00 | NULL | NULL | NULL | 96 | NULL | NULL | NULL | | | C | A | 113 | 3 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 0 | 0 | NULL | | 2.9 | 3 | 3.13 | 0 | | 0.152 | ITI | NULL | murs en blocs de béton creux | 23 | 90 | 26.25 | 90 | 0.19 | | | | | dalle béton | 95.58 | 95.58 | 0.14 | NULL | | | | | plafond bois sous solives bois | 95.58 | 95.58 | 0.13 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003698T | 13 | 0 | dpe arrêté 2012 facture logement | appartement | avant 1948 | 1920 | | NULL | 2013-10-22 00:00:00 | NULL | NULL | NULL | 40 | NULL | NULL | NULL | | | N | N | 0 | 0 | | | | | | | | 0 | NULL | NULL | | | | | | chauffe-eau independant indetermine | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | | NULL | | NULL | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003699U | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1975-1977 | 1975 | | NULL | 2013-10-22 00:00:00 | NULL | NULL | NULL | 118 | NULL | NULL | NULL | | | C | C | 116.64 | 20.44 | individuel | gaz | chaudiere gaz standard | | bois | poele ou insert bois | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 5.56 | 17.48 | 0 | 0 | NULL | non traversant | 2.2 | 2.2 | 0.38 | 1 | [ "nord", "sud" ] | NULL | ITI | NULL | murs en béton banché | 20 | 50.49 | 0 | 50.49 | 1.11 | | | | non isole | dalle béton | 67.5 | 67.5 | 2 | NULL | | | | ITI | plafond en plaque de plâtre | 67.5 | 67.5 | 0.56 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003700D | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1989-2000 | 1989 | | NULL | 2013-10-22 00:00:00 | NULL | NULL | NULL | 105 | NULL | NULL | NULL | | | C | A | 128 | 5 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 0 | 0 | 6 | 4 | NULL | est ouest | 2.2 | 2.8 | 0.47 | 0 | [ "est", "ouest" ] | 0.122 | ITI | NULL | murs en blocs de béton creux | 20 | 100 | 72 | 72 | 0.35 | | | | ITI | | 52 | 52 | 0.61 | NULL | | | | ITI | plafond avec ou sans remplissage sous combles | 52 | 52 | 0.23 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003704H | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1948 | | NULL | 2013-10-22 00:00:00 | NULL | NULL | NULL | 80 | NULL | NULL | NULL | | | E | E | 240 | 47 | individuel | gaz | chaudiere gaz standard | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 7.78 | 3 | 5.3 | 0 | NULL | tout venant | 3.8 | 4.5 | 0.48 | 1 | [ "nord", "ouest", "sud" ] | 0.25 | non isole | NULL | murs en briques pleines doubles avec lame d'air | 35 | 105.12 | 48.21 | 86.5 | 1.55 | | | | non isole | dalle béton | 80.35 | 0 | 2 | NULL | | | | non isole | dalle béton | 80.35 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003705I | 13 | 0 | dpe arrêté 2012 3cl immeuble | immeuble | 2006-2012 | 2010 | | NULL | 2013-10-22 00:00:00 | NULL | NULL | NULL | NULL | NULL | NULL | NULL | | | A | A | 50.16 | 1.71 | individuel | solaire | chauffage solaire | | electricite | pac air/eau | | 1 | NULL | NULL | electricite | pac air/air | | collectif | | ecs solaire | | electricite | ecs thermodynamique electrique(pac ou ballon) | | 1 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | argon ou krypton | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 4.68 | 10.18 | 0.53 | 3.07 | NULL | tout venant | 2.1 | 2.4 | 1.55 | 0 | [ "est", "nord", "ouest", "sud" ] | 0.102 | ITI | NULL | murs en blocs de béton creux | NULL | 163.14 | 163.14 | 163.14 | 0.29 | | | | ITE | dalle béton | 90 | 90 | 0.17 | NULL | | | | ITI | dalle béton | 180 | 90 | 0.14 | | | | | NULL | NULL | Moyenne | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003706J | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1960 | | NULL | 2013-10-22 00:00:00 | NULL | NULL | NULL | 57 | NULL | NULL | NULL | | | D | C | 218.46 | 18.31 | individuel | gaz | chaudiere gaz standard | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | simple vitrage | bois | | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 0 | 0 | 8.31 | 11.51 | NULL | est ouest | 1.4 | 1.4 | 0.56 | 0 | [ "est", "ouest" ] | NULL | non isole | NULL | murs en béton banché | 20 | 50.29 | 0 | 29.59 | 2 | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003707K | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2013-10-23 00:00:00 | NULL | NULL | NULL | 60 | NULL | NULL | NULL | | | C | A | 100 | 3 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | métal avec rupture de pont thermique | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0 | 6.06 | 1.35 | 0 | NULL | non traversant | 2.9 | 3.4 | 0.48 | 1 | [ "ouest", "sud" ] | 0.196 | ITI | NULL | murs en béton banché | 20 | 32.39 | 30.39 | 32.39 | 0.4 | | | | | dalle béton | 60.13 | 0 | 0.36 | NULL | | | | | dalle béton | 60.13 | 0 | 0.27 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003708L | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2001-2005 | 2001 | | NULL | 2013-10-23 00:00:00 | NULL | NULL | NULL | 147 | NULL | NULL | NULL | | | C | D | 116 | 26 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Extracteur mécanique sur conduit non modifié de ventilation naturelle existante | | double vitrage | métal avec rupture de pont thermique | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 0 | 5.4 | 23.6 | 2.8 | NULL | tout venant | 2.9 | 3.4 | 0.48 | 1 | [ "est", "ouest", "sud" ] | 0.18 | ITI | NULL | murs en briques pleines doubles avec lame d'air | 35 | 144.4 | 144.4 | 144.4 | 0.47 | | | | ITE | dalle béton | 87.39 | 87.39 | 0.43 | NULL | | | | ITI | plafond bois sous solives bois | 59.32 | 59.32 | 0.3 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003709M | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1983-1988 | 1984 | | NULL | 2013-10-23 00:00:00 | NULL | NULL | NULL | 103 | NULL | NULL | NULL | | | D | B | 159.19 | 7.69 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | bois | air sec | Persienne coulissante ou volet battant PVC, volet battant bois (e > 22 mm) | NULL | 0 | 5.96 | 4.76 | 0 | 0 | NULL | tout venant | 2.4 | 3.1 | 0.43 | 1 | [ "indetermine", "nord", "sud" ] | 0.173 | ITI | NULL | murs en blocs de béton creux | 25 | 93.87 | 81.99 | 93.87 | 0.34 | | | | ITI | dalle béton | 59 | 59 | 0.35 | NULL | | | | ITI | combles aménagés sous rampant | 85 | 85 | 0.29 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003711F | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1948-1974 | 1951 | | NULL | 2013-10-23 00:00:00 | NULL | NULL | NULL | 71 | NULL | NULL | NULL | | | F | C | 359.77 | 20.85 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | simple vitrage | bois | air sec | Fermeture sans ajours en position déployée, volets roulants alu | NULL | 0 | 2.88 | 8.16 | 1.44 | 0 | NULL | tout venant | 3.7 | NULL | 0.52 | 0 | [ "nord", "ouest", "sud" ] | 0.179 | non isole | NULL | murs en blocs de béton creux | 25 | 80.44 | 57.35 | 80.44 | 1.9 | | | | non isole | dalle béton | 71 | 71 | 2 | NULL | | | | ITI | plafond bois sous solives bois | 71 | 71 | 0.34 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003712 | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1974 | | NULL | 2013-10-23 00:00:00 | NULL | NULL | NULL | 52 | NULL | NULL | NULL | | | E | C | 234.43 | 10.67 | individuel | electricite | pac air/eau | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | argon ou krypton | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 1.39 | 3.94 | 0 | 0 | NULL | nord sud | 2.4 | 2.6 | 0.44 | 1 | [ "nord", "sud" ] | NULL | non isole | NULL | murs en blocs de béton creux | NULL | 62.32 | 0 | 44.82 | 2 | | | | non isole | dalle béton | 52 | 52 | 0.35 | NULL | | | | ITI | dalle béton | 52 | 0 | NULL | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003713H | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1974 | | NULL | 2013-10-23 00:00:00 | NULL | NULL | NULL | 52 | NULL | NULL | NULL | | | E | C | 234.43 | 10.67 | individuel | electricite | pac air/eau | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | pvc | argon ou krypton | Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout métal, volets battants ou persiennes avec ajours fixes | NULL | 0 | 1.39 | 3.94 | 0 | 0 | NULL | nord sud | 2.4 | 2.6 | 0.44 | 1 | [ "nord", "sud" ] | NULL | non isole | NULL | murs en blocs de béton creux | NULL | 62.32 | 0 | 44.82 | 2 | | | | non isole | dalle béton | 52 | 52 | 0.35 | NULL | | | | ITI | dalle béton | 52 | 0 | NULL | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003714I | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1974 | | NULL | 2013-10-23 00:00:00 | NULL | NULL | NULL | 68 | NULL | NULL | NULL | | | F | C | 351.77 | 20.27 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ecs solaire | | electricite | ballon accumulation electrique | | 1 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | pvc | argon ou krypton | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 3.26 | 9.9 | 1.46 | 0 | NULL | tout venant | 1.9 | 2.2 | 0.35 | 0 | [ "indetermine", "nord", "ouest", "sud" ] | 0.382 | non isole | NULL | murs en béton banché | 20 | 45.95 | 24.41 | 45.95 | 2 | | | | | | NULL | NULL | NULL | NULL | | | | ITI | plafond avec ou sans remplissage | 68.39 | 68.39 | 1.45 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003715J | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1978-1982 | 1978 | | NULL | 2013-10-23 00:00:00 | NULL | NULL | NULL | 89 | NULL | NULL | NULL | | | D | B | 216 | 10 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Système de ventilation par entrées d’air hautes et basses | | double vitrage | bois | | Persienne coulissante ou volet battant PVC, volet battant bois (e ≤ 22 mm) | NULL | 0 | 6.58 | 4.02 | 1.2 | 0.24 | NULL | tout venant | 2.5 | 3.2 | 0.47 | 1 | [ "est", "nord", "ouest", "sud" ] | 0.152 | ITI | NULL | murs en blocs de béton creux | 20 | 135.67 | 67.38 | 99.67 | 0.35 | | | | ITE | dalle béton | 49 | 49 | 0.59 | NULL | | | | ITI | plafond avec ou sans remplissage sous combles | 44.5 | 44.5 | 0.22 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003716K | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2013-10-23 00:00:00 | NULL | NULL | NULL | 30 | NULL | NULL | NULL | | | D | B | 206 | 7 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | métal sans rupture de pont thermique | | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 4.71 | 0 | 0 | 0 | NULL | non traversant | 3 | NULL | 0.57 | 1 | [ "nord" ] | 0.343 | ITI | NULL | murs en béton banché | 20 | 33.89 | 9.04 | 19.64 | 0.4 | | | | non isole | dalle béton | 30.26 | 0 | 2 | NULL | | | | non isole | dalle béton | 30.26 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003717L | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1948-1974 | 1958 | | NULL | 2013-10-23 00:00:00 | NULL | NULL | NULL | 73 | NULL | NULL | NULL | | | D | B | 156 | 6 | individuel | electricite | pac air/air | | electricite | generateurs a effet joule | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | métal avec rupture de pont thermique | | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 0 | 0 | 3.83 | NULL | est ouest | 3.8 | NULL | 0.56 | 1 | [ "est", "est ou ouest" ] | 0.339 | ITI | NULL | murs en béton banché | 30 | 72.63 | 24.53 | 40.63 | 2 | | | | non isole | dalle béton | 73 | 0 | 2 | NULL | | | | non isole | dalle béton | 73 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003718M | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 2006-2012 | 2006 | | NULL | 2013-10-23 00:00:00 | NULL | NULL | NULL | 99 | NULL | NULL | NULL | | | C | A | 148.53 | 5.95 | individuel | electricite | pac air/eau | | electricite | generateurs a effet joule | | 0 | NULL | NULL | electricite | pac air/air | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | argon ou krypton | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 0 | 2.8 | 5.23 | 6.57 | NULL | tout venant | 2.6 | 2.6 | 0.44 | 0 | [ "est", "ouest", "sud" ] | 0.122 | ITI | NULL | murs en blocs de béton creux | 20 | 125.2 | 105.2 | 125.2 | 0.4 | | | | ITE | plancher à entrevous isolant | 90.1 | 90.1 | 0.45 | NULL | | | | ITI | plafond en plaque de plâtre | 86.3 | 86.3 | 0.19 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003719N | 13 | 0 | dpe arrêté 2012 facture logement | appartement | avant 1948 | 1945 | | NULL | 2013-10-23 00:00:00 | NULL | NULL | NULL | 156 | NULL | NULL | NULL | | | N | N | 0 | 0 | | | chaudiere energie indetermine standard | | | | | 0 | NULL | NULL | | | | | | chaudiere energie indetermine standard | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | bois | | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | | NULL | | NULL | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003721G | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2001-2005 | 2003 | | NULL | 2013-10-23 00:00:00 | NULL | NULL | NULL | 48 | NULL | NULL | NULL | | | D | B | 222.32 | 9.84 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | métal sans rupture de pont thermique | air sec | Volet roulant PVC ( e ≤ 12 mm) | NULL | 0 | 1.82 | 4 | 0 | 0 | NULL | nord sud | 4.4 | 4.4 | 0.49 | 0 | [ "nord", "sud" ] | NULL | ITI | NULL | murs en blocs de béton creux | 20 | 49.54 | 0 | 49.54 | 0.47 | | | | | | NULL | NULL | NULL | NULL | | | | ITI | dalle béton | 33.8 | 33.8 | 0.3 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003722H | 13 | 0 | dpe arrêté 2012 facture logement | appartement | avant 1948 | 1900 | | NULL | 2013-10-23 00:00:00 | NULL | NULL | NULL | 13 | NULL | NULL | NULL | | | N | N | 0 | 0 | | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation naturelle par conduit | | double vitrage | bois | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | | NULL | | NULL | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003723I | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 1975-1977 | 1975 | | NULL | 2013-10-23 00:00:00 | NULL | NULL | NULL | 40 | NULL | NULL | NULL | | | D | E | 211 | 49 | individuel | gaz | chaudiere gaz standard | | | | | 0 | NULL | NULL | | | | individuel | | chaudiere gaz standard | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | métal sans rupture de pont thermique | air sec | | NULL | 0 | 0 | 14 | 0 | 0 | NULL | non traversant | 4.4 | NULL | 0.49 | 0 | [ "sud" ] | 0.7 | non isole | NULL | | 0 | 45 | 6 | 20 | 2 | | | | non isole | | 40 | 0 | 2 | NULL | | | | non isole | plafond avec ou sans remplissage | 40 | 0 | 1.45 | | | | | NULL | NULL | Légère | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003724J | 13 | 0 | dpe arrêté 2012 3cl logement | appartement | 2006-2012 | 2006 | | NULL | 2013-10-23 00:00:00 | NULL | NULL | NULL | 62 | NULL | NULL | NULL | | | D | B | 155 | 6 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique à extraction et entrées d’air hygroréglables | | double vitrage | pvc | air sec | Volet roulant PVC ( e > 12 mm) | NULL | 0 | 0 | 5.14 | 0 | 7.15 | NULL | 90° | 1.8 | 2.2 | 0.39 | 0 | [ "est", "sud" ] | 0.273 | ITI | NULL | murs en béton banché | 20 | 50.71 | 32.71 | 50.71 | 0.4 | | | | ITE | dalle béton | 62 | 62 | 0.36 | NULL | | | | non isole | dalle béton | 62.05 | 0 | 2.5 | | | | | NULL | NULL | Très Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003726L | 13 | 0 | dpe arrêté 2012 3cl logement | maison | 1983-1988 | 1988 | | NULL | 2013-10-23 00:00:00 | NULL | NULL | NULL | 97 | NULL | NULL | NULL | | | D | C | 218.11 | 11.35 | individuel | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | individuel | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation mécanique auto réglable « après 1982 » | | double vitrage | pvc | air sec | | NULL | 0 | 0.6 | 0 | 4.2 | 10.5 | NULL | tout venant | 2.6 | 2.6 | NULL | 0 | [ "est", "nord", "ouest" ] | 0.166 | ITI | NULL | murs en blocs de béton creux | 20 | 89.49 | 77.12 | 82.21 | 0.78 | | | | ITI | dalle béton | 97.1 | 97.1 | 0.35 | NULL | | | | ITI | plafond bois sous solives bois | 97.1 | 97.1 | 0.34 | | | | | NULL | NULL | Lourde | NULL | NULL | NULL | NULL | NULL | NULL |
| 1313V1003727M | 13 | 0 | dpe arrêté 2012 facture logement | appartement | avant 1948 | 1900 | | NULL | 2013-10-23 00:00:00 | NULL | NULL | NULL | 54 | NULL | NULL | NULL | | | N | N | 0 | 0 | | electricite | generateurs a effet joule | | | | | 0 | NULL | NULL | | | | | | ballon accumulation electrique | | | | | 0 | NULL | NULL | 0 | Ventilation par ouverture des fenêtres | | double vitrage | pvc | air sec | | NULL | 0 | NULL | NULL | NULL | NULL | NULL | | NULL | NULL | NULL | 0 | | NULL | | NULL | | NULL | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | NULL | | | | | | NULL | NULL | NULL | | | | | NULL | NULL | | NULL | NULL | NULL | NULL | NULL | NULL |